Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-12-01T17:02:33Z
No. of bitstreams: 1
2016_WilsonEmilioDavidSánchez.pdf: 4528528 bytes, checksum: 58574bf9caab44c9095ac1d76b4e3104 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-01-28T17:34:29Z (GMT) No. of bitstreams: 1
2016_WilsonEmilioDavidSánchez.pdf: 4528528 bytes, checksum: 58574bf9caab44c9095ac1d76b4e3104 (MD5) / Made available in DSpace on 2017-01-28T17:34:29Z (GMT). No. of bitstreams: 1
2016_WilsonEmilioDavidSánchez.pdf: 4528528 bytes, checksum: 58574bf9caab44c9095ac1d76b4e3104 (MD5) / No controle estrutural, os dispositivos passivos do tipo histeréticos são destacados devido ao seu baixo custo e alta ductilidade. Estes dispositivos dissipam a energia através de um mecanismo que é independente da taxa de frequência do carregamento, número de ciclos da carga ou variação da temperatura. Na presente pesquisa analisa-se numericamente, com apoio do programa MATLAB, dois procedimentos propostos pelo Izuru Takewaki, os quais consistem na determinação da localização ótima dos amortecedores do tipo histerético num edifício do tipo Shear building. Estes procedimentos são conhecidos como: (a) Problema inverso incremental para o reprojeto de sistema estrutural com um amortecimento arbitrário para a função de transferência objetivo e (b) Procedimento sistemático para encontrar a localização ótima de amortecedores, minimizando a soma das amplitudes da função de transferência. Os resultados obtidos mostraram que o método da localização ótima minimizando a soma das amplitudes da função de transferência foi eficiente ao apresentar uma redução entre 16% e 31% da amplitude da função de transferência para edifícios conformados entre dois e dez pavimentos respectivamente. / In structural control, passive hysteretic devices are highlighted due to their low cost and high ductility. These devices dissipate energy through a mechanism that is independent of charging rate frequency, number of charge cycles, or temperature variation. In this work a numerical analysis is done, with the support of MATLAB program over two procedures proposed by Izuru Takewaki, which consist in determining the optimal placement of the hysteretic dampers in a Shear building. These procedures are known as: (a) incremental inverse problem for redesign of structural system with an arbitrary damping system for target transfer functions and (b) systematic procedure to find the optimal damper placement to minimize the sum of amplitudes of the transfer functions. The results showed that the optimal placement method minimizing the sum of the amplitudes of the transfer function is efficient by showing a reduction between 16% and 31% of the amplitude of the transfer function for buildings conformed between two and ten floors respectively.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/22290 |
Date | 09 September 2016 |
Creators | David Sánchez, Wilson Emilio |
Contributors | Avila, Suzana Moreira, Brito, José Luís Vital de |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds