Return to search

Desenvolvimento de sensores eletroquímicos e métodos de extração em fase sólida baseados em sistemas biomiméticos para análise de poluentes ambientais

Made available in DSpace on 2015-07-13T12:10:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-10-10. Added 1 bitstream(s) on 2015-07-13T12:24:11Z : No. of bitstreams: 1
000820027_20151001.pdf: 172545 bytes, checksum: 7aa5a9090b99c494b46ef43f9b5da08c (MD5) Bitstreams deleted on 2015-10-01T13:00:56Z: 000820027_20151001.pdf,. Added 1 bitstream(s) on 2015-10-01T13:01:39Z : No. of bitstreams: 1
000820027.pdf: 4250245 bytes, checksum: 3efa9b83618dace7a6a21db3d5345513 (MD5) / Este trabalho apresenta o desenvolvimento de sistemas de análise usando compostos biomiméticos para determinação de poluentes ambientais. O primeiro sistema biomimético proposto para a enzima P450 se baseou no uso de eletrodos modificados com compostos supramoleculares de ftalocianina ou porfirina metálicas, que mimetizaram a ferro protoporfirina IX, que é o sítio ativo catalítico das enzimas P450. Os complexos avaliados permitiram que os sensores modificados apresentassem características vantajosas, como excelente atividade catalítica e alta transferência eletrônica. A comprovação da biomimetização foi realizada através de dados obtidos usando amperometria e voltametria de onda quadrada. Os complexos utilizados nesse estudo como potenciais mimetizadores da enzima P450 para monitoramento dos agrotóxicos 2,4-D, diuron, carbofurano e do fármaco diclofenaco foram, respectivamente, o cloro 5,10,15,20-tetraquis(pentafluorofenil)-21H,23H-porfirina ferro (III); o 29H,31H-ftalocianina-1,4,8,11,15,18,22,25-octabutoxi níquel (II); a hemina e a 29H,31H-ftalocianina-1,4,8,11,15,18,22,25-octabutoxi cobre (II). Adicionalmente, neste período foi desenvolvido um sensor eletroquímico para detecção de thiram, usando eletrodo impresso modificado com nanotubos de carbono. Os sensores propostos apresentaram tanto em sistemas em batelada como em fluxo (FIA), uma sensibilidade entre 1,0 x 104 e 1,1 x 105 μA L mol-1 e um limite de detecção que variou entre 2,0 x 10-6 e 1,3 x 10-5 mol L-1. Quando avaliada a seletividade dos sensores com outras substâncias químicas foi verificada alta seletividade nos potenciais de análise de cada analito. Por exemplo, o sensor biomimético para determinação de diuron, apresentou sinal eletroquímico somente para este analito quando realizada amperometria em potencial de 750 mV, não apresentando resposta para os outros compostos analisados (carbofurano, thiram... / This work presents the development of systems using biomimetic compounds for determination of environmental pollutants. The first proposed biomimetic system is based on modification of electrodes with supramolecular compounds of phthalocyanine or porphyrin metal, that mimicked the iron protoporphyrin IX (active site of P450 enzymes). The complex evaluated in this work allowed the constructed sensors with some advantageous characteristics such as excellent catalytic activity and high electronic transfer. The verification of the biomimetization was performed through data obtained by amperometry and square-wave voltammetry. The complexes used in this study as potential catalysts P450 enzyme for monitoring of pesticides 2,4-D, diuron, carbofuran and the drug diclofenac were, respectively, the chlorine 5,10,15,20-tetrakis(pentafluorofenil)-21H22,23H-porphyrin iron (III); the 29H,31H)-phthalocyanine-1,4,8,11,15,18,22,25-octabutoxi nickel (II); the hemin and 29H,31H)-phthalocyanine-1,4,8,11,15,18,22,25-octabutoxi copper (II). Furthermore, during this period a sensor was developed for the detection of thiram using carbon nanotube modified electrode. The proposed sensors showed in batch and flow (FIA) systems, sensitivity between 1.0 x 104 and 1.1 x 105 L mol-1 μA and a detection limit between 2.0 x 10-6 and 1.3 x 10-5 mol L-1. When evaluated the selectivity of the sensor with other compounds was observed high selectivity, for example, the biomimetic sensor showed only electrochemical signal for diuron when performed amperometry in potential of 0.75 V. The compounds were carbofuran, thiram, chlorpyrifos, metribuzin, 2,4-D, hexazinone, ametryn, profenofos and carbendazim. The stability and reproducibility of the sensors were realized satisfactory with calibration curves with RSD of 4%. When applied to real samples (soil samples, water from rivers, biological serum, pharmaceutical formulations), the results...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/124524
Date10 October 2014
CreatorsWong, Ademar [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Sotomayor, Maria Del Pilar Taboada [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format172 f. : il. -
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0019 seconds