Return to search

Efeitos da filtragem de leucócitos sobre a resposta inflamatória e a função pulmonar de pacientes submetidos à revascularização miocárdica com circulação extracorpórea / Effects of leukocyte filtering on the inflammatory response and pulmonary function in patients undergoing coronary artery bypass grafting with cardiopulmonary bypass

INTRODUÇÃO E OBJETIVOS: A Circulação extracorpórea (CEC) é associada a ativação leucocitária, resposta inflamatória e disfunção pulmonar. Objetivou-se avaliar os efeitos da filtragem leucocitária sobre a resposta inflamatória e a função pulmonar em indivíduos submetidos à revascularização do miocárdio (RM) com CEC. MÉTODO: Após aprovação pelo Comitê de Ética Institucional e obtenção do consentimento informado dos indivíduos, foi realizado estudo prospectivo randomizado, para comparar indivíduos adultos submetidos à RM com CEC, utilizando-se filtragem leucocitária (n=09) ou filtro standard (n=11) durante a CEC. Tomografia computadorizada (CT) de tórax, espirometria, análise da oxigenação e hemograma foram realizados antes da cirurgia. A anestesia foi induzida por via venosa com etomidato (0,3 mg.kg-1), sufentanil (0,3 ug.kg-1), pancurônio (0,08 mg.kg-1) e mantida com isoflurano (0,5 - 1,0 CAM) e sufentanil (0,5 ug.kg-1.h-1). A ventilação mecânica utilizou volume corrente de 8 mL.kg-1, com FiO2 de 0,6 e PEEP de 5 cm H2O, exceto durante a CEC. No grupo Filtragem, durante a CEC, foi inserido um filtro de leucócitos na linha arterial do circuito (LG-6, Pall Biomedical Products) e, no grupo Controle, foi utilizado o filtro Standard. Contagem leucocitária foi realizada após a indução, aos 5, 25 e 50 min de CEC, ao final da cirurgia, com 12 e 24 h PO. Dados hemodinâmicos, PaO2/FiO2, fração de Shunt, interleucinas, elastase e mieloperoxidase foram colhidos antes e após a CEC, no final da cirurgia, com 6,12 e 24 h PO. Trinta minutos depois da indução, e trinta após a CEC, três amostras sequenciais de ar exalado foram colhidas para análise de óxido nítrico (NO), por quimiluminescência. Espirometria e CT de tórax foram realizadas no primeiro dia pós-operatório. Os dados foram analisados por meio de ANOVA de duplo fator para medidas repetidas. RESULTADOS: O tempo de CEC foi similar entre os grupos controle e filtragem (86,78 ± 19,58 versus 104,64 ± 27,76 min, p=0,161). O grupo Filtragem mostrou menor contagem leucocitária que o grupo Controle até 50 min de CEC (3384 ± 2025 versus 6478 ± 3582 U.mm-3 U.mm-3, p=0,036), menor fração de shunt até 6 h PO (10 ± 2% versus 16 ± 5%, p=0,040) e menores níveis de IL-10 até o final da cirurgia (1571 ± 1137 pg.mL-1 versus 3108 ± 1694 pg.mL-1, p=0,031). Não houve diferença estatisticamente significativa entre os grupos em relação ao restante dos parâmetros avaliados (p > 0,05). CONCLUSÕES: A filtragem leucocitária durante a CEC, quando comparada à utilização de filtro convencional, promove diminuição da contagem de neutrófilos até 50 minutos de CEC, menor liberação de IL-10 até o final da cirurgia e menor alteração da fração de shunt intrapulmonar até 6 h PO, protegendo os pulmões apenas temporariamente contra a injúria aguda relacionada / BACKGROUND AND OBJECTIVE: The Cardiopulmonary bypass (CPB) is related to leukocyte activation, inflammatory response and lung dysfunction. The aim of this study was to evaluate the effects of CPB-leukocyte filtration on the inflammatory response and lung function after coronary artery bypass grafting (CABG). METHODS: After approval by the institutional ethics committee and informed consent, a prospective randomized study was performed to compare CABG-patients undergoing CPB-leukocyte filtration (n=9) or standard CPB (n=11). Espirometry, chest computed tomography (CT), oxygenation analysis and leukocyte count were performed before surgery. Anesthesia induction was performed intravenously with etomidate (0,3 mg.kg-1), sufentanil (0,3 ug.kg-1), pancuronium bromide (0,08 mg.kg-1) e sustained with isoflurano (0,5 - 1,0 CAM) and sufentanil (0,5 ug.kg-1.h-1). The tidal volume used during mechanical ventilation was 8 mL.kg-1, the FiO2 0.6 and PEEP 5 cm H2O, except during CPB. In Filtered group, during CPB, was inserted a leukocyte filter in the arterial line of CPB circuit (LG-6, Pall Biomedical Products) and, in Control group, the Standard arterial line filter was utilized. Hemodynamic data, PaO2/FiO2, shunt fraction, interleukins, elastase and myeloperoxidase were evaluated before and after CPB, at the end of surgery, and 6, 12 and 24 h PO. Thirty minutes after induction, and Thirty after CPB, three sequential exhaled air samples were collected to perform analysis of nitric oxide (NO), by chemiluminescence technique. Espirometry and chest CT were performed on first PO. Data were analyzed using two-factor ANOVA for repeated measurements. RESULTS: Length of CPB was similar in the filtered and control groups (86.78 ± 19.58 versus 104.64 ± 27.76 min, p = 0.161). The filtered group showed lower neutrophil counts than the control group up to 50 minutes of CPB (3384 ± 2025 versus 6478 ± 3582 U/mm-3, p = 0.036), lower shunt fraction up to 6 hours after surgery (10 ± 2% versus 16 ± 5%, p = 0.040), and lower levels of IL-10 at the end of surgery (1571 ± 1137 pg.ml-1 versus 3108 ± 1694 pg.ml-1, p = 0.031). There were no significant differences between the groups with respect to rest of the parameters evaluated (p >u0,05). CONCLUSIONS: The leukocyte filtration during CPB, when compared to the use of conventional filter, promotes lower neutrophil counts up to 50 minutes of CPB, lower levels of IL-10 at the end of surgery and lower shunt fraction up to 6 hours after surgery, protecting the lungs only temporarily against the acute injury related Trial registration: Clinicaltrials.gov identifier: NCT01469676

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-25112014-152216
Date09 September 2014
CreatorsCelio Gomes de Amorim
ContributorsMaria Jose Carvalho Carmona, Luiz Fernando dos Reis Falcão, David Ferez, Elnara Márcia Negri, Denise Aya Otsuki
PublisherUniversidade de São Paulo, Anestesiologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0126 seconds