Return to search

An?lise mec?nica da resist?ncia da fixa??o na osteotomia sagital do ramo ap?s diferentes movimentos de avan?o mandibular: estudo in vitro

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-04-03T23:22:20Z
No. of bitstreams: 1
GleyssonMatiasDeAssis_DISSERT.pdf: 1359858 bytes, checksum: fe9b88f922668d56c2a5d194da819485 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-04-12T00:40:00Z (GMT) No. of bitstreams: 1
GleyssonMatiasDeAssis_DISSERT.pdf: 1359858 bytes, checksum: fe9b88f922668d56c2a5d194da819485 (MD5) / Made available in DSpace on 2017-04-12T00:40:00Z (GMT). No. of bitstreams: 1
GleyssonMatiasDeAssis_DISSERT.pdf: 1359858 bytes, checksum: fe9b88f922668d56c2a5d194da819485 (MD5)
Previous issue date: 2017-02-10 / O objetivo deste trabalho foi de avaliar, atrav?s de um ensaio mec?nico, a resist?ncia da fixa??o na osteotomia sagital do ramo mandibular (OSRM) em tr?s diferentes movimentos de avan?o mandibular, bem como a influ?ncia do movimento associado a rota??o hor?rio do plano mandibular, utilizando miniplacas (4 e 6 elos) e parafusos com 6 mm de comprimento, do sistema 2.0 mm (Egimplan? ). Dois tipos de avan?os foram empregados (6 e 12 mm), utilizando hemimand?bulas de poliuretano com OSRM padronizadas de f?brica, divididos em 5 grupos: G1(Teste 1) - avan?o linear de 6 mm/ 1 placa e 4 parafusos; G2 (Teste 2) - avan?o linear de 12 mm/1 placa e 4 parafusos; G3 (Teste 3)- avan?o linear de 12 mm /2 placas e 8 parafusos; G4 (Teste 4) - avan?o de 12 mm, associado a rota??o hor?ria do plano mandibular(15?) / 1 placa e 4 parafusos; G5 (Teste 5) - avan?o de 12 mm, associado a rota??o hor?rio do plano mandibular(15?)/2 placas e 8 parafusos. As hemimand?bulas foram submetidas a uma carga compressiva vertical na regi?o de primeiro molar e a for?a aplicada, em Newtons, foi registrada nos deslocamentos de 1mm, 5 mm e 10 mm, como tamb?m a for?a m?xima aplicada entre 1 e 10 mm. Utilizando um intervalo de confian?a de 95%, as m?dias de for?a foram obtidas e os grupos foram comparados entre si. Os testes estat?sticos utilizados foram o Kruskal-Wallis* para a an?lise de todos os grupos e o de Mann-Whitney** para o comparativo de dois grupos em separado. Os resultados mostraram que o grupo G3 apresentou m?dias de for?a maiores (p < 0,001*), sendo, portanto, o mais resistente entre os grupos. Quando foi utilizado apenas 1 placa para a fixa??o da hemimandibula, no avan?o de 12 mm, a realiza??o da rota??o hor?ria foi mais resistente do que no movimento linear, nos deslocamentos de 1, 5 e 10 mm (p< 0,05**), n?o resultando em diferen?a estat?stica apenas no deslocamento m?ximo (p= 0,112**). Em um grande avan?o (12mm) houve uma perda de resist?ncia importante na fixa??o, sendo necess?rio compensar essa situa??o com uso de mais fixa??o e a rota??o hor?rio nesses casos tamb?m acrescentaram resist?ncia na OSRM, apenas nos casos em que se utiliza uma ?nica placa. / The objective of this study was to evaluate by means of mechanical testing the fixation strength in sagittal split ramus osteotomy (SSRO) for three different movements of mandibular advancement, as well as the influence of movement associated with clockwise rotation of the mandibular plane, using miniplates (4 and 6 holes) and 6-mm screws of the 2.0 mm system (Engimplan?). Two types of advancement were employed (6 and 12 mm) using polyurethane hemimandibles with factory-standardized SSO, divided into five groups: G1 (test 1) ? linear advancement of 6 mm/1 plate and 4 screws; G2 (test 2) ? linear advancement of 12 mm/1 plate and 4 screws; G3 (test 3) ? linear advancement of 12 mm/2 plates and 8 screws; G4 (test 4) ? advancement of 12 mm associated with clockwise rotation of the mandibular plane (15?)/1 plate and 4 screws; G5 (test 5) ? advancement of 12 mm associated with clockwise rotation of the mandibular plane (15?)/2 plates and 8 screws. The hemimandibles were submitted to a vertical compressive load in the region of the first molar and the force applied (in Newton) was recorded for displacements of 1, 5 and 10 mm, as was the maximum force applied between 1 and 10 mm. Using a 95% confidence interval, the mean force values were obtained and compared between groups. The Kruskal-Wallis* test was used for analysis of all groups and the Mann-Whitney** test for the comparison of two groups. The results showed higher mean force values for G3 (p < 0.001*), which was therefore the treatment that provided the greatest strength. When only 1 plate was used for fixation of the hemimandible, in the advancement of 12 mm, clockwise rotation resulted in a greater fixation strength than the linear movement for displacements of 1, 5 and 10 mm (p < 0.05**), with no significant difference being observed only for the maximum displacement (p = 0.112**). Important loss of strength in fixation was observed for the large advancement (12 mm) and it was necessary to compensate this situation with the use of more fixation. Clockwise rotation added strength to the SSO only in cases in which a single plate was used.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/22637
Date10 February 2017
CreatorsAssis, Gleysson Matias de
Contributors91405963468, http://lattes.cnpq.br/9542712980723391, Silva, Alessandro Costa da, 12138523829, Gomes, Petrus Pereira, 11736693883, http://lattes.cnpq.br/1355518681045639, Germano, Adriano Rocha
PublisherPROGRAMA DE P?S-GRADUA??O EM SA?DE COLETIVA, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds