Dissertação (mestrado profissional) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação Multidisciplinar em Saúde, Florianópolis, 2016. / Made available in DSpace on 2017-01-24T03:20:26Z (GMT). No. of bitstreams: 1
343439.pdf: 2257007 bytes, checksum: e5c5aec55baa278fd0be518baa05787d (MD5)
Previous issue date: 2016 / Este estudo teve como objetivo a validação de um instrumento visando a padronização do cuidado de enfermagem no manuseio de cateter venoso totalmente implantado (CVTI) em um Hospital Universitário Federal. Trata-se de uma pesquisa de desenvolvimento metodológico com abordagem quantitativa e teve como embasamento metodológico o modelo de Hoskins (1989) adaptado para validação de um instrumento de cuidado. A pesquisa foi desenvolvida em duas etapas. A primeira etapa foi realizada em experiência acadêmica anterior e consistiu na construção de um instrumento de cuidado com enfermeiros que lidavam diariamente com o dispositivo (RAMOS, 2014). No presente estudo foi desenvolvida a segunda etapa e foi realizada em duas fases: na primeira fase foi realizada a validação por especialistas do instrumento através de um formulário eletrônico, onde foi verificado o perfil dos expertos e a validação de conteúdo do instrumento de cuidado; e na segunda fase foi realizada a validação clínica através de observação direta estruturada da realização das três técnicas pelos mesmos enfermeiros que participaram anteriormente da construção do instrumento de cuidado. Os resultados foram explanados através da estatística descritiva e evidenciam a complexidade que envolve a assistência ao CVTI, além de apontar a importância da validação de instrumentos para qualificar o cuidado de enfermagem. Conclui-se que os resultados possam contribuir para o cuidado aos pacientes oncológicos que possuem o dispositivo, além de ampliar o conhecimento dos profissionais enfermeiros, visando maior segurança no manuseio do cateter, prevenindo assim o surgimento de complicações.<br> / Abstract : This study aimed to validate an instrument aimed at the standardization of nursing care in the totally implantable venous catheters at a Federal University Hospital. This is a methodological development research with a quantitative approach and had as the methodological basis the Hoskins model (1989) adapted to validate a care instrument. The research was conducted in two stages. The first stage was held in the previous academic experience and consisted in a building care instrument with nurses who dealt daily with the device (RAMOS, 2014). In this study we developed the second stage and was conducted in two phases: the first phase was carried out by the validation tool experts through an electronic form, which found the profile of experts and the care of instrument content validation; and in the second phase clinical validation was conducted through structured direct observation of the realization of the three techniques by the same nurses who previously participated in the construction of care instrument. The results were explained by descriptive statistics and show the complexity that involves assistance CVTI, while pointing out the importance of validation tools to qualify nursing care. We have conclude that the results can contribute to the care of cancer patients who have the device, in addition to expanding the knowledge of nursing professionals seeking greater safety in handling the catheter, thus preventing the onset of complications.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/172582 |
Date | January 2016 |
Creators | Ramos, Bianca Jacqueline |
Contributors | Universidade Federal de Santa Catarina, Bertoncello, Kátia Cilene Godinho |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 155 p.| il., tabs. |
Source | reponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0075 seconds