Return to search

Estudo de biodisponibilidade de 2 formulações de ciclosporina em sangue de voluntarios sadios por radioimunoensaio e imunofluorescencia

Orientador: Gilberto de Nucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T03:29:56Z (GMT). No. of bitstreams: 1
Mendes_GustavoDuarte_M.pdf: 15864596 bytes, checksum: 09970d46e36b10883e44d62f84b26e12 (MD5)
Previous issue date: 2003 / Resumo: O objetivo deste estudo foi comparar a biodisponibilidade de duas formulações (Sigmasporin Microoral® da Novaquímica Divisão Nature's Plus, Brasil, formulação teste e Sandimmun Neoral® da Novartis Biociências S.A, Brasil,
como formulação referência) de cápsula de ciclosporina em 24 voluntários sadios do sexo masculino. O estudo foi conduzido aberto, aleatorizado, dois períodos com intervalo de uma semana entre as doses. Amostras de sangue total foram
obtidas em intervalos de até 12 horas após administração de cada cápsula de ciclosporina. As concentrações sanguíneos de ciclosporina foram quantificadas por Imunoensaio de Fluorescência Polarizada (FPIA) produzidos por Abbott e por
radioimunoesnaio (RIA) produzidos por DiaSorin. Utilizando estes testes obtivemos as curvas de concentrações sanguíneos de ciclosporina e os parâmetros farmacocinéticos (ASC último, ASCinf, Cmax). A média geométrica e os intervalos de confiança de 90% para Microoral®/Neoral® foram94.5% (90.8-98.4%) para ASC último,93.8 % (89.7-98.1%) para ASC inf e 98.1% (94.5-101.8%) para Cmax no FPIA e foram 96.1% (91.9-100.6%) para ASC último,95.2 % (90.2-100.5%) para
ASC inf, and 99.4% (96.4-102.4%) para Cmax no RIA. Considerando que os intervalos de 90% para as razões geométricas de Cmax, ASC último e ASC inf estão dentro dos intervalos estabelecidos pela Food and Drug Administration (80-125%), conclui-se que a formulação de cápsula de 100 mg de ciclosporina elaborada pelos laboratórios Nature's Plus Farmacêutica Ltda/Sigma Pharma é bioequivalente à cápsula de 100 mg de ciclosporina (Sandimmun Neoral® elaborada pelos Laboratórios Novartis Biociências S.A, tanto para a taxa como para extensão da absorção / Abstract: Objective: the aim of study was to compare the bioavailability of two cyclosprine capsule formulations (100 mg; SigmasporinMicrooral® from NovaquímicaDivisão Nature's Plus Farmaceutica Ltd., Brazil, as test formulation and Sandimmun Neoral® from Novartis Biociências S.A., Brazil, as reference formulation) in 24 healthy male volunteers. Methods: The study was conducted in an open, randomized, two-period crossover fashion with an one-week washout interval
between doses. Blood samples were obtained over a 12-hour interval after each cyclosporine oral administration (2 capsules of 100 mg of each formulation). Cyclosporine blood concentrations were quantified by a Fluorescence Polarization
Immunoassay (FPIA) System provided by Abbott Axsym® System and by Cyclo- Trac® SP - Whole Blood Radioimmuoassay (RIA) kit provided by DiaSorin®.Using these assays we obtained the time curves of cyclosporin blood concentration and
the following pharmacokinetic parameters were also evaluated: AUClast, AUCinf, Cmax. Results: geometric mean and 90% confidence intervals (CI) of Microoral® /Neoral@percent ratio were 94.5% (90.8-98.4%) for AUC last, 93.8%
(89.7-98.1%) for AUCinf,and 98.1% (94.5-101.8%) for Cmax asdetermined by using FPIA and were 96.1% (91.9-100.6%) for AUClast,95.2 % (90.2-100.5%) for AUCinf, and 99.4% (96.4-102.4%) for Cmaxas determined by using RIA. Conclusion: since
the 90% CI for Cmax,AUClastand AUCinf ratio were within the 80-125% interval proposed by US-FDA, it is concluded that Sigmasporin Microoral@100 mg capsule formulation is bioequivalent to Sandimmun Neoral®100 mg capsule formulation for
both the rate and the extent of absorption / Mestrado / Farmacologia / Mestre em Farmacologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/309499
Date08 April 2003
CreatorsMendes, Gustavo Duarte
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, De Nucci, Gilberto, 1958-, Nucci, Gilberto de, 1958-, Figueiredo, Jose Francisco, Marcondes, Sisi
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Farmacologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format151p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds