Return to search

Análise do COP anual de condicionadores de ar tipo Split fixo e inverter nas diferentes zonas bioclimáticas brasileiras

Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-08-01T14:35:36Z
No. of bitstreams: 1
Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) / Made available in DSpace on 2018-08-01T14:35:36Z (GMT). No. of bitstreams: 1
Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5)
Previous issue date: 2018-04-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta uma análise da relação entre o desempenho de equipamentos de condicionamento de ar tipo Split, fixo e inverter, para a climatização de uma edificação comercial nas diferentes zonas bioclimáticas brasileiras. As análises foram realizadas por simulação computacional, através do programa EnergyPlus. Foram simulados oito casos seguidos pelo modelo de referência. O modelo de referência adotado foi criado a partir de um levantamento fotográfico de edificações comerciais padrões com mais de quatro pavimentos. A partir deste levantamento, a tipologia que foi adotada representa um edifício de dez pavimentos com perímetro de dimensões de 27 por 7,50 metros e, pé-direito de 2,60 metros. Para analisar o comportamento energético do modelo de referência foram inseridos dados dos componentes construtivos, do padrão de ocupação, das cargas energéticas do sistema de iluminação e dos equipamentos, do condicionamento de ar, com as suas respectivas curvas de desempenho, conforme fornecedor, e de infiltração, conforme norma. Com esses dados inseridos no EnergyPlus, foi possível dimensionar a carga térmica dos equipamentos de ar condicionado e seu desempenho energético, analisados através do COP anual simulado desses equipamentos. Com a simulação foi possível destacar os fatores que influenciam no consumo de energia de um sistema de ar condicionado no que diz respeito às condições climáticas, principalemente o impacto da temperatura externo no desempenho do equipamento. Nos resultados encontrados foi possível identificar que existe uma influência bastante significativa, principalmente quando se comparam regiões de alta temperatura externa e com de baixa temperatura externa e, em um segundo momento, valores altos e baixos de umidade relativa interna do ar ambiente, sendo que, altas umidades favorecem o desempenho do equipamento avaliado. Resultados bastante significativos foram encontrados na substituição de aparelhos Split fixo por aparelhos Split inverter, nos quais se alcançou uma redução de até 44% de economia em regiões específicas do país, seu COP anual simulado apresentou um indicador mais eficiente em todas as horas simuladas. / This work presents an analysis of the relationship between the performance of split, fixed and inverter air conditioning equipment for the air conditioning of a commercial building in the different Brazilian bioclimatic zones. Analyzes were performed by computer simulation using the EnergyPlus program. Eight cases followed by the reference model were simulated. The reference model adopted was created from a photographic survey of standard commercial buildings with more than four floors. From this survey, the typology that was adopted represents a ten-storey building with a perimeter of dimensions of 27 by 7.50 meters and, at the foot of 2.60 meters. In order to analyze the energy performance of the reference model, data were included on the building components, occupancy pattern, energy loads of the lighting system and equipment, air conditioning, with their respective performance curves, as supplier, and infiltration, according to norm. With these data inserted in the EnergyPlus, it was possible to measure the thermal load of the air conditioning equipment and their energy performance, analyzed through the simulated annual COP of this equipment. With the simulation, it was possible to highlight the factors that influence the energy consumption of an air conditioning system with regard to climatic conditions, mainly the impact of external temperature on the performance of the equipment. In the results, it was possible to identify that there is a significant influence, especially when comparing high temperature and external low temperature regions, and in a second moment, high and low values of internal relative humidity of the ambient air, high performance favors the performance of the equipment evaluated. Significant results were found in the replacement of fixed split devices with split inverter devices, in which a reduction of up to 44% of savings was achieved in specific regions of the country, its annual simulated COP showed a more efficient indicator at all simulated hours.

Identiferoai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/7126
Date12 April 2018
CreatorsRech, Letícia Dotta
Contributorshttp://lattes.cnpq.br/3438508833347823, Wander, Paulo Roberto
PublisherUniversidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Mecânica, Unisinos, Brasil, Escola Politécnica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds