Comportamento mecanico de restaurações multiplas implanto-retidas frente a presença de desajustes marginais / Mechanical behaviour of non passive multi unit implant restorations

Orientador: Guilherme Elias Pessanha Henriques / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T22:13:01Z (GMT). No. of bitstreams: 1
Daroz_LuizGustavoDias_D.pdf: 1960257 bytes, checksum: 5da5124c6018514dbf5ec8de5bf7228a (MD5)
Previous issue date: 2009 / Resumo: A obtenção de uma estrutura protética passivamente adaptada aos implantes e pilares de conexão tem sido sugerida como fundamental para se evitar falhas mecânicas e biológicas nas reabilitações implanto-retidas. Um melhor entendimento dos efeitos da deficiência de passividade poderia ajudar a entender a mecânica destas falhas. O objetivo desta tese foi estudar os efeitos da presença de desajustes marginais sobre o comportamento mecânico de restaurações múltiplas implanto-retidas. Uma série de estudos foi desenvolvida para avaliar como a presença, a magnitude e a localização dos desajustes marginais afetam a estabilidade das conexões parafusadas e a transferência de cargas para os pilares de conexão. O tipo de estrutura implanto-retida foi o mesmo em todos os estudos realizados, consistindo de uma estrutura metálica fundida em titânio comercialmente puro e parafusada sobre três pilares de conexão do tipo MicroUnit (Conexão Sistemas de Prótese). Diferentes níveis de desajuste marginal (15mm, 100mm, 150mm e 300mm) foram simulados, sendo estes localizados em diferentes pilares (pilar central ou pilar distal) no modelo em estudo, propiciando amplo padrão de comparações entre diversas condições de passividade. Ensaios de determinação da força de torque necessária para o afrouxamento dos parafusos de retenção, bem como ensaios extensiométricos para a determinação da magnitude e direção das forças incidentes no sistema implanto-retido, foram utilizados. Os resultados mostraram que a presença de desajustes marginais diminui a estabilidade dos parafusos de retenção e aumenta as cargas incididas no sistema implanto-retidos, contudo sem uma clara relação doseefeito. A localização dos desajustes influencia na magnitude e direção das cargas incididas no sistema, contudo, para a maior parte das situações testadas, o pilar central parecer ser o que recebe a maior intensidade de carga independente da localização do desajuste. Frente às condições onde os desajustes foram simulados, a intensidade das cargas de flexão foi muito pequena independe do nível do desajuste marginal. Isso pode indicar que a simulação de desajustes marginais, mesmo sendo ferramenta efetiva em termos de comparação, poderia propiciar um comportamento mecânico distinto que em uma situação clínica real. / Abstract: A passive fit between the implant prosthetic framework and its supporting abutments has been required to avoid mechanical and biological complications. A more profound knowledge about the effects of a non passive framework over its supporting abutments would help to better understand the mechanics behind these failures. The objective of this thesis was to study the mechanical behavior of implant supported restorations under different misfit situations. A series of studies was design to evaluate how framework misfits would affect the stability of the retaining screws and the stresses transferred to the implant abutments. In every study in this thesis, the implant-supported model consisted of a screw-retained multi-unit framework set over three tapered abutments MicroUnit type (Conexão Sistema de Prótese). Different misfit magnitudes - 15mm, 100mm, 150mm, and 300mm - and different misfit locations - on the central abutment or distal abutment - of implant framework to its supporting abutments were simulated to create several misfit conditions, allowing multiple comparisons. Screws loosening torque tests, as well as, strain gauge analysis, were used respectively to evaluate the screw stability and the stress generation over the implant abutments. The results showed that the misfit between the implant framework and its supporting abutments can reduce the retaining screw stability and increase the amount of stress induced to the system, but a clear dose-response effect between misfit magnitude and stress generation could not be observed. The location of the misfit can affect the stress magnitude and the stress pattern. However, the central abutment seemed to be the one that received the most intense stress despite misfit location and magnitude. The bending stresses were very low despite the misfit magnitude. This could indicate that the simulation of a vertical misfit between the implant framework and its supporting abutments may provide a different stress generation pattern than in a clinical situation. / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289182
Date02 September 2009
CreatorsDaroz, Luiz Gustavo Dias
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Henriques, Guilherme Elias Pessanha, 1968-, Junior, Francisco de Assis Mollo, Mesquita, Marcelo Ferraz, Nóbilo, Mauro Antonio de Arruda
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format76 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds