Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2011. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2012-04-25T12:29:20Z
No. of bitstreams: 1
2011_AureaOtoniDeOliveiraCanha.PDF: 555585 bytes, checksum: 37783361a929c28707451b4a1330166c (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2012-04-25T12:29:33Z (GMT) No. of bitstreams: 1
2011_AureaOtoniDeOliveiraCanha.PDF: 555585 bytes, checksum: 37783361a929c28707451b4a1330166c (MD5) / Made available in DSpace on 2012-04-25T12:29:33Z (GMT). No. of bitstreams: 1
2011_AureaOtoniDeOliveiraCanha.PDF: 555585 bytes, checksum: 37783361a929c28707451b4a1330166c (MD5) / Introdução: A utilização dos analisadores de frequências indica a pressão sonora
para cada frequência presente no ruído. Esse procedimento associado à avaliação
dos limiares audiométricos em altas frequências pode auxiliar na prevenção dos
danos auditivos. Objetivo: Verificar a associação entre o espectro de ruído e a
configuração audiométrica em trabalhadores e analisar a utilidade clínica do uso de
audiometria de alta frequência. Método: Estudo clínico-epidemiológico, do tipo analíticotransversal,
realizado no Distrito Federal, no período de 2008-2009. Realizaram-se
avaliação ambiental do ruído em empresas de diferentes ramos de atividade econômica
e avaliação audiológica (convencional e de alta frequência) em 347 trabalhadores,
precedidas de anamnese ocupacional. Resultados: A análise espectral revelou
picos nas frequências de 8kHz no ramo metalúrgico, 4kHz em marmoraria e 2kHz
em madeireira. A presença de entalhe sugestivo de perda auditiva induzida por ruído
(PAIR) entre os trabalhadores foi de 55,3% na avaliação audiométrica convencional
e de 78,0%, na de altas frequências, A média dos limiares auditivos aumentou com o
aumento da frequência. Na análise pos hoc, verificou-se que as frequências de
14kHz (p=0,011) e 16kHz (p=0,015) apresentaram diferenças significativas entre os
ramos de atividade, sendo a metalúrgica a de maior prevalência. Conclusão: A relação
entre o nível equivalente de pressão sonora (Leq), em 8kHz e 16kHz, e o tipo de
configuração audiométrica identificado pode ser evidenciada principalmente no ramo
metalúrgico, que apresentou espectro numa frequência alta (8kHz), sugerindo que
as características físicas do ruído podem ser o principal fator de risco na presença de
entalhes auditivos. A realização da audiometria de alta frequência foi determinante para
a identificação desses comprometimentos. Por isso, a avaliação auditiva sistemática
do trabalhador nas frequências de 9-20kHz e a avaliação ambiental identificando o
espectro de ruído podem contribuir na identificação precoce de danos auditivos. ______________________________________________________________________________ ABSTRACT / Introduction: The use of frequency analyzers indicates the sound pressure for each
noise frequency. This procedure associated to the evaluation of audible thresholds in
high frequencies may support preventing hearing damage. Objective: To verify the
association between noise spectrum and the audiometric configuration in workers and to
analyze the clinical utility of high-frequency audiometry. Method: Clinico-epidemiological
study, from the cross-sectional analytical type, performed in the Federal District (Brazil),
in 2008 and 2009. Environmental evaluation of noise was made in companies from
different economical activity branches and audiological evaluations (conventional and
high-frequency) were made in 347 workers, preceded by occupational anamnesis.
Results: The spectrum analysis revealed peak at 8Hz in the metallurgic industry,
peak at 4Hz in marble industry and at 2Hz in the wood industry. The notch suggestive
of noise-induced hearing loss (NIHL) among workers was 55.3% in the conventional
audiometric evaluation, and 78.0% in the high-frequency audiometric evaluation. The
average of audible thresholds raised at the highest evaluated frequencies. In the
pos hoc analysis, it was verified that the 14 kHz (p=0.011) and 16 kHz (p=0.015)
frequencies presented significant differences among the activity branches, being the
metallurgic industry with highest prevalence. Conclusion: The relation between the
equivalent sound pressure level (Leq), at 8kHz and 16kHz, and the identified type
of audiometric configuration can be evidenced mainly in the metallurgic branch,
that presented spectrum at a high frequency (8kHz), suggesting that the physical
characteristics of noise may be the main risk factor with the presence of hearing
notch. The performance of high-frequency audiometry was decisive to identify these
exposures. Therefore, the systematic auditory evaluation in workers at 9-20kHz
frequencies and environmental evaluation identifying noise spectrum can contribute
to identify precocious hearing damage.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/10327 |
Date | 01 July 2011 |
Creators | Canha, Áurea Otoni de Oliveira |
Contributors | Branco, Anadergh Barbosa de Abreu |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds