Made available in DSpace on 2014-11-10T11:09:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-05-09Bitstream added on 2014-11-10T11:57:27Z : No. of bitstreams: 1
000790320.pdf: 1643575 bytes, checksum: 51c9824f3dfb47616dd9fdeb65aa4430 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Ao considerar as diferentes formas de poluição em áreas urbanas e industriais, destaca-se o material particulado atmosférico (MP) devido ao seu potencial tóxico e diferentes composições químicas. Metais tóxicos associados ao MP são considerados nocivos à saúde e para diferentes espécies da biota. Embora na literatura os estudos referentes à determinação de metais em MP sejam pequenos, é de grande valia o conhecimento do fluxo de deposição desses elementos a fim de indicar possíveis fontes, prever efeitos devidos sua toxicidade e possibilitar no futuro, o estabelecimento de futuras Políticas Públicas quando se mostrarem necessários, uma vez que os mesmos não possuem legislação bem definidas. Em consequência disso, o presente trabalho teve como objetivo a determinação de Cd, Pb e Cu em material particulado atmosférico da cidade de Presidente Prudente, SP. A cidade de Presidente Prudente, SP possui quatro pequenos distritos industriais, tem acesso às rodovias de importância estadual e até nacional. Em termos agrícola, o cultivo da cana-de-açúcar representa área colhida de aproximadamente 50,8%. As amostras de material particulado foram coletadas em quatro áreas de grande densidade veicular e circulação de pessoas na cidade, sendo elas: Estação Meteorológica da Faculdade de Ciências e Tecnologia da UNESP, no terminal rodoviário da cidade de Presidente Prudente, na Praça 9 de Julho e UBS Vila Real, utilizando-se amostradores passivos, onde as partículas foram depositadas pela ação da gravidade em papel filtro quantitativo com porosidade de 2μm. Foram estudadas 80 amostras coletadas num período de quinze dias, período que compreendeu entre 27 de março de 2011 a 03 de abril de 2013. A quantificação dos metais foi realizada por meio da técnica voltamétrica de pulso diferencial com redissolução anódica utilizando eletrodo de mercúrio no modo gota pendente. Os parâmetros experimentais ... / When considering the different forms of pollution in urban and industrial areas, the atmospheric particulate matter (MP) stands out thanks to its toxic potential and different chemical compositions. Toxic metals associated to MP are considered noxious to the health and to different species of the biota. Even though in the literature the studies that refer to the metal determination in MP are small, it of big significance knowing the flow deposition of these elements in order to indicate possible roots, predict effects due to its high toxicity and to allow in the future, establishing future Public Politic when it is displayed necessary, since these same ones doesn’t have well defined legislations. As a consequence, the present work has as objective the determination of Cd, Pb and Cu in atmospheric particulate matter in the city of Presidente Prudente, SP. The city of Presidente Prudente, SP has four small industrial districts have access to state highways and even national importance. In agricultural terms, the cultivation of sugar cane is harvested area of approximately 50.8%. The samples of particulate matter were collected in four areas of great automobile density and people circulation in the city these being: The Weather Station of the Faculty of Sciences and Technology of UNESP, in the bus terminal of the city of Presidente Prudente, in the 9 de Julho square and UBS Vila Real. 80 collected samples were studied for a term of fifteen days, term comprehended between March 27 of 2011 and April 03 of 2013. The quantification of the metals was done through the Voltammetric technique of differential pulses with anodic stripping using mercury electrode in the pendant droplet way. The optimized experimental parameters, sample volume and pre-concentration time were of 4,0 mL and 150s, respectively. For the determined elements, the decomposition method selected was with 65% nitric acid (v/v). The results were valued in relation to the ...
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/110689 |
Date | 09 May 2014 |
Creators | Proença, Camila dos Anjos [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Teixeira, Marcos Fernando de Souza [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 76 f. : il. color., tabs. |
Source | Aleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | -1, -1 |
Page generated in 0.0027 seconds