Return to search

Uso da capnografia volumetrica associada a espirometria na identificação da disfunção pulmonar na fibrose cistica / Use of volumetric capnography associated with spirometry for the identification of pulmonary dysfunction in cystic fibrosis

Orientadores: Ilma Aparecida Paschoal, Marcos Tadeu Nolasco da Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T05:09:59Z (GMT). No. of bitstreams: 1
Ribeiro_MariaAngelaGoncalvesdeOliveira_D.pdf: 4389859 bytes, checksum: d2d733c3beb145d2d27f1d75c4c068fd (MD5)
Previous issue date: 2010 / Resumo: Objetivo: Verificar parâmetros da espirometria e da capnografia volumétrica na identificação do padrão respiratório e da homogeneidade da ventilação em crianças e adolescentes com fibrose cística (FC) e compará-los com indivíduos saudáveis. Método: Estudo de corte transversal com crianças e adolescentes com e sem FC. Os pacientes foram divididos em dois grupos em função da idade: Grupo I (42 fibrocisticos entre seis e 12 anos) e Grupo II (22 fibrocisticos entre 13 e 20 anos) e seus respectivos controles foram de 20 e de 74 sujeitos saudáveis. Foram avaliados pela espirometria a capacidade vital forçada (CVF), volume expiratório no primeiro segundo (VEF1) e o índice VEF1/CVF; e na capnografia, a oximetria de pulso (SpO2), freqüência respiratória (FR), tempo inspiratório (Ti), tempo expiratório (Te) e slope 3 normalizado por volume corrente (slope 3/Ve). Resultados: comparados aos controles, os pacientes do Grupo I apresentam menor SpO2 (p< 0,001), menor Ti (p=0,047), e maiores valores de slope3/Ve (p<0,001). Vinte e quatro pacientes do Grupo I tiveram espirometria normal e apresentaram valores maiores do slope3/Vê quando comparados ao grupo controle (p=0,036). Os pacientes do Grupo II apresentaram menores valores de SpO2 (p< 0,001), menor Ti (p< 0,001), menor Te (p< 0,001), maiores valores de FR (p< 0,001) e de slope3/Ve (p< 0,001) quando comparados aos seus controles e piores valores de CVF, VEF1 e VEF1/CVF (p< 0,05) quando comparados ao Grupo I. Conclusão: Comparados aos controles, os pacientes com fibrose cística mostraram maiores valores do slope 3, indicando disfunção da periferia das vias aéreas em todos os grupos estudados. A capnografia volumétrica identificou a não homogeneidade da distribuição da ventilação nas vias aéreas periféricas dos pacientes com espirometria normal. Descritores: eliminação de CO2 por respiração; slope 3/Ve; capnografia volumétrica; espirometria; fibrose cística. / Abstract: Objective: To evaluate spirometry and capnography parameters on identification of respiratory pattern and homogeneity of ventilation in patients with CF and to compare them to healthy subjects. Method: 64 patients diagnosed with cystic fibrosis based on the finding of at least two abnormal sweat chloride concentrations determined by the quantitative pilocarpine iontophoresis sweat test performed capnography and spirometry in the morning return to the medical staff. Patients were divided into two groups according to age: Group I (42 patients aged 6 to 12 years) and Group II (22 patients between 13 to 20 years) and their controls were 20 and 74 patients respectively. Spirometrics parameters studied were Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1) and FEV1/FVC index. Capnography parameters studies were, oxygen saturation (SpO2), respiratory rate (RR), inpiratory time (IT) expiratory time (ET) and phase 3slope normalized by tidal volume (slope 3/EV). Results: compared to controls, patients in Group I had presented lower SpO2 (p< 0,001), lower Ti (p = 0.047), and higher values of slope3/Ve (p <0.001). Twentyfour patients in Group I had normal spirometry and had higher values slope3/Ve when compared to the control group (p = 0.036). Patients in Group II had significantly lower SpO2 (p< 0,001), lower IT (p< 0,001), lower ET (p< 0,001), and higher values of FR (p< 0,001) and slope3/Ve (p< 0,001), and worst values of FVC, FEV1 and FEV1/FVC (p <0.05) compared to Group I. Conclusion: Compared to controls, patients with CF showed an increased slope 3. These results indicate dysfunction of the peripheral airways in all CF patients groups. Volumetric capnography identified the heterogeneity of the ventilation distribution in the peripheral airways of patients with normal spirometry. / Doutorado / Saude da Criança e do Adolescente / Doutor em Saude da Criança e do Adolescente

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/309673
Date02 April 2010
CreatorsRibeiro, Maria Angela Gonçalves de Oliveira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Silva, Marcos Tadeu Nolasco da, 1960-, Paschoal, Ilma Aparecida, 1956-, Rozov, Tatiana, Adde, Fabiola Villac, Toro, Adyléia Aparecida Dalbo Contrera, Toro, Ivan Felizardo Contrera
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Saúde da Criança e do Adolescente
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format163 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds