Return to search

Comparação entre protocolos de marcadores anatomicos e tecnicos para analise cinematica na marcha e na corrida / Comparison of technical and anatomical markers protocols for kinematical analysis in the walking and in the running

Orientador: Ricardo Machado Leite de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-08T23:00:32Z (GMT). No. of bitstreams: 1
Miana_AndreiaNogueira_M.pdf: 1861684 bytes, checksum: 665eaddcfbbcd37b0517005f4dfb680e (MD5)
Previous issue date: 2007 / Resumo: O propósito deste trabalho foi comparar dois protocolos para análise cinemática de velocistas em função das velocidades, segmentos corporais e ângulos articulares durante a marcha e a corrida. Um protocolo utiliza marcadores fixados diretamente sobre a pele e outro utiliza marcadores montados sobre estruturas rígidas fixadas no segmento corporal. Seis velocistas do sexo masculino, usando ambos os protocolos, andaram a 5 Km/h e correram a 20 Km/h, em uma esteira ergométrica. Os velocistas foram representados por um modelo tridimensional constituído por quinze segmentos corporais: cabeça, tórax, pelve, pés, pernas, coxas, braços e antebraços. Foram utilizadas oito câmeras de vídeo digital (120 Hz) para aquisição das imagens e a calibração das câmeras e reconstrução das coordenadas 3D dos marcadores foram feitas no software Dvideo®. O tratamento e análise dos dados foram feitos em ambiente Matlab??7.0. Os resultados mostraram que a variabilidade do comprimento dos segmentos e das distâncias entre os marcadores e a diferença máxima entre os ângulos obtidos por cada protocolo foram maiores com o aumento da velocidade, mostrando que os erros na análise do movimento durante a corrida foram maiores que estes durante a marcha. Não houve efeito das velocidades na correlação entre os ângulos obtidos por cada protocolo. A variabilidade da distância entre os marcadores foi maior nos membros inferiores do que nos membros superiores e a variabilidade do comprimento da perna foi maior do que esta nos outros segmentos. Os resultados também mostraram que a maior correlação foi encontrada entre os ângulos de flexão/extensão (0,99) obtidos por cada protocolo e para cada articulação, seguido dos ângulos de adução/abdução (0,78) e dos ângulos de rotação interna/externa (0,65). E os menores valores encontrados na diferença angular máxima foram entre os ângulos de flexão/extensão (6,3° ± 3,4°) obtidos por cada protocolo e para cada articulação, seguido dos ângulos de adução/abdução (13,2° ± 7,9°) e dos ângulos de rotação interna/externa (17,2° ± 8,4°). Os protocolos não apresentaram diferenças na variabilidade do comprimento dos segmentos e também na análise da cinemática angular, porém os ângulos de adução/abdução e rotação externa/interna devem ser observados com mais cautela / Abstract: The purpose of this study was to compare two protocols for kinematical analysis of sprinters according to velocities, body segments and joint angles during walking and running. The first protocol uses retroreflective markers mounted on fixtures attached to the body segment and the second uses retroreflective markers directly located on the skin surface. Six male athletes were studied during treadmill running at 5 and 20 Km/h and recorded with eight 120 Hz video cameras. A three-dimensional model constituted by fifteen segments represented the sprinters: head, thorax, pelvis, the right and left feet, shanks, thighs, scapulas, arms and forearms. The calibration of the cameras, the synchronization of the registrations and the 3D reconstruction of the coordinates of the markers were done in the Dvideo ® software. All data were analyzed using Matlab® 7.0. The results show that the variability of the length of the segments and of the distances between the markers and the maximum difference maximum between the angles obtained by each protocol were higher with the increase of the velocities, showing that the errors in the analysis of the movement during the running were larger than these ones during the gait. There was no effect of the velocities in the correlation between the angles obtained by each protocol. The variability of the distances between the markers in the lower limb were higher than this one in the upper limbs and the variability of the length of the shank was higher than this one in the other segments. The results also showed a higher correlation was found between the flexion/extension angles (0,99) obtained by each protocol and for each joint, followed by the abduction/adduction angles (0,78) and the angles of internal/external rotation (0,65). The lower values found in the maximum angular difference were between the flexion/extension angles (6,3° ± 3,4°) obtained by each protocol and for each articulation, followed by the abduction/adduction angles (13,2° ± 7,9°) and the angles of internal/external rotation (17,2° ± 8,4°). No differences were found in the variability of the length of the segments and also in the analysis of the angular kinematics, however the adduction/abduction and internal/external rotation angles should be regarded with much more caution / Mestrado / Biodinamica do Movimento Humano / Mestre em Educação Física

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/275217
Date08 March 2007
CreatorsMiana, Andreia Nogueira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Barros, Ricardo Machado Leite de, 1961-, Menzel, Hans-Joachim, Mercadante, Luciano Allegretti
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Educação Física, Programa de Pós-Graduação em Educação Física
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format109p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds