<p>An extensive investigation of front-door protection devices i.e. limiters has been made. The thesis work contains both HPM- and UWB-measurements done on various limiters, in order to characterize them. The measurements show that all limiters are not suitable as protection against HPM- and UWB-pulses. The limiters that were found to provide the best protection are limiters based on diode technologies. PIN- and Schottky-diodes generally shows very good performance and they fulfill many parameters that have been set by FOI. To obtain a full protection it is presumably necessary to use two or more limiters in combination, which complement each other.</p> / <p>En omfattande studie av framvägskopplingsskydd, dvs. limiters har gjorts. Examensarbetet innehåller resultat från både HPM- och UWB- mätningar som har gjorts på olika limitrar för att karaktärisera deras prestanda. Av resultaten från mätningarna kan man se att alla limitrar inte passar som skydd mot HPM- och UWB-pulser. De limitrar som tillhandahöll det bästa skyddet var baserade på olika diodtekniker. PIN- och Schottky-dioder visade sig överlag ha väldigt goda prestanda och de uppfyller många av de parametrar som bestämts av FOI. För att få ett heltäckande skydd är det förmodligen nödvändigt att man använder två eller flera limitrar i kombination, som kompletterar varandra.</p>