Desenvolvimento de método cromatográfico para determinação de ingredientes ativos de formulações fotoprotetoras e uso da fluorescência de raios-x para a determinação do fator de proteção solar / Development of chromatographic method for the determination of active ingredients in suscreen formulations and use of X-ray fluorescence to determine the sun protection factor

Orientador: Susanne Rath / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-17T08:45:18Z (GMT). No. of bitstreams: 1
Peruchi_LiviaManiero_M.pdf: 2606610 bytes, checksum: 4b1e6756287ec6b3404f0fe6512fb307 (MD5)
Previous issue date: 2010 / Resumo: Este trabalho teve como objetivo desenvolver e validar um método por cromatografia líquida de alta eficiência para a determinação de oito compostos ativos amplamente utilizados em protetores solares: benzofenona-3, octocrileno, metil benzilideno canfora, octil dimetil PABA, metoxicinamato de etilexila, butil metoxidibenzoilmetano, homosalato (usado nas suas duas formas isoméricas) e salicilato de etilexila. A separação dos compostos foi realizada em uma coluna cromatográfica ACE C18 (250 mm x 4.6 mm, 5 mm), na temperatura de 20 °C e fase movel composta por metanol:agua 88:12 v/v com eluição isocrática. A vazão foi de 1 mL min e a quantificação foi feita por padronização externa no comprimento de onda máximo de cada composto. O tempo da corrida cromatográfica foi de 18 minutos. O preparo de amostra consistiu basicamente de diluição e filtração anterior quantificação. Os parâmetros considerados na validação do método foram: faixa linear, linearidade, sensibilidade, precisão intra e inter-ensaio e exatidão. O método foi aplicado em treze amostras de diferentes fabricantes disponíveis comercialmente. O número de compostos ativos variaram entre 1 e 5 em uma mesma amostra. As concentrações dos compostos estão na faixa de 0,9-10% (m/m) e estão de acordo com o limite máximo permitido pela ANVISA. Este trabalho teve tambem como objetivo avaliar a potencialidade do uso de fluorescência de raios-X para determinar o FPS (fator de proteção solar) de protetores solares utilizando métodos quimiométricos. Para isso foram selecionadas varias amostras de um mesmo fabricante com diferentes FPS. Os espectros de raios-X obtidos foram tratados com a ferramenta quimiométrica PCA (Principal Component Analysis) para a análise exploratória dos dados e então construiu-se um modelo de calibração por PLS (Partial Least Squares). / Abstract: This work describes the development and validation of a HPLC-DAD method for determination of eight sunscreen agents: benzophenone-3, octocrylene, octyl methoxycinnamate, octyl salicylate, homosalate (used in two isomeric forms), butyl metoxydibenzoylmethane, 4-metylbenzylidene camphor and octyl dimetyl PABA in sunscreen formulations. The separation of the eight compounds were achieved using a ACE C18 column (250 mm x 4.6 mm, 5 mm), column temperature 20 °C, and a mobile phase of 88:12 (v/v) methanol-water with isocratic elution. The flow rate was 1 mL/min and quantitation was performed by external calibration at the maximum wavelength of each compound. Total run time was 18 minutes. The sample preparation was simple and consisted basically of dilution and filtration before quantitation. The critical points of the method are the column temperature, composition of the C18 stationary phase and the composition of the mobile phase. The validation parameters comprised: linear range, linearity, selectivity, intra-day and inter-day precision, and accuracy, and were in accordance with the aim of the method. Thirteen samples of sunscreen emulsions (SPF 30) of different manufacturer were analyzed. The number of the sunscreen agents varied between one and five in a same sample. The concentrations of all compounds were in the range of 0.9 to 10% (m/m) and were in accordance with the current Brazilian legislation. This work has also evaluated the potential of use of X-ray fluorescence to determine the SPF (sun protection factor) of sunscreens using chemometric methods. For this purpose, several samples from the same manufacturer (same components) with different FPS were selected. The X-ray spectra obtained were treated with a chemiometric tool PCA (Principal Component Analysis) for exploratory data analysis and then built a calibration model by PLS (Partial Least Squares). / Mestrado / Mestre em Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/249422
Date08 February 2010
CreatorsPeruchi, Livia Maniero, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Rath, Susanne, 1962-, Sakakibara, Isarita Martins, Jardim, Isabel Cristina Sales Fontes
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Química, Programa de Pós-Graduação em Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format107 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds