Return to search

Validação do instrumento para mensuração do impacto da doença no cotidiano de pacientes valvopatas

Orientador: Maria Cecilia Bueno Jayme Gallani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-04T09:44:49Z (GMT). No. of bitstreams: 1
Padilha_KatiaMelissa_M.pdf: 6172357 bytes, checksum: b3712bccfb1c3bfe26b9df7e8aee7cf6 (MD5)
Previous issue date: 2005 / Resumo: Este trabalho teve como objetivo verificar as propriedades psicométricas do IDCV- Instrumento para mensuração do Impacto da Doença no Cotidiano do Valvopata no que se refere a: - validade de conteúdo; validade de constructo, por meio da análise fatorial e da validade divergente correlacionando-o com o IQV - Índice de Qualidade de Vida de Ferrans e Powers; -validade de critério correlacionando-o com a Medida Geral de Impacto da Doença e com o IEQ - Questionário para Avaliação do Impacto de Doenças Crônicas; e - consistência interna. A população deste estudo foi constituída por 120 pacientes valvopatas, atendidos no Ambulatório de Cardiologia do HCIUNICAMP. Os resultados obtidos foram submetidos às análises: descritiva; análise fatorial, correlação de Pearson e alfa de Cronbach. A análise fatorial gerou quatro fatores que explicaram em 58% a variância nas respostas: 1. Impacto físico da doença (sintomas); 2.Impacto da doença nas atividades cotidianas; 3.Impacto social e emocional da doença e 4. Adaptação à doença. Houve correlação que variou de fraca a moderada magnitude entre o escore total do IDCV e de seus fatores (3 e 4) e o IQV, comprovando sua validade divergente. Verificou-se correlação de forte magnitude entre o escore total do IDCV e o IEQ, de fraca a moderada magnitude entre os fatores 1, 2 e 3 do IDCV e o IEQ e entre o escore total do IDCV e de seus fatores 2 e 3 e a Medida Geral de Impacto da Doença, comprovando sua validade de critério. Foi constatado coeficiente alfa de Cronbach = 0,74, o que evidência a consistência interna do instrumento. Os resultados do presente estudo confirmam a validade de constructo e de critério, e apontam para consistência interna do IDCV. Estudos futuros são necessários para confirmar sua confiabilidade e fornecer maiores subsídios para a melhor compreensão do significado das dimensões do impacto mensuradas pelo IDCV, bem como para avaliar a responsividade do instrumento a intervenções de saúde. Apesar das características do estudo que impedem a generalização dos resultados e ampla recomendação do uso do IDCV, pode-se afirmar que este instrumento representa um passo inicial importante nos esforços para a maior compreensão sobre a vivência com a valvopatia e a eficácia das intervenções de saúde implementadas neste contexto / Abstract: The aim of this work was to verify the psychometric properties of the IDCV -Instrument for Measuring the Impact of Illness in the Daily Life of the valve heart in terms of: -content validity construct validity, by means ofthe factorial analysis and analysis of the divergent validity correlating it with the Life Quality Index (IQV) and - criterion validity, correlating it with the General Measure of Impact of Illness and with the Illness Effects Questionnaire (IEQ) - reliability.The subjectsthis studywere 120 patients with valve heart disease, who were attended at in the Cardiology Clinic at HC/UNICAMP. Data were submitted to the following analyses: descriptive, factorial analysis, Pearson's correlation coefficient and Cronbach' s Alpha coefficient. The factorial analysis generated four factors that explained in 58% the answers variance: 1. Physical impact of the illness (symptoms); 2.Impact of illness in the daily activities; 3.Social and emotional impact of illness and 4. Adaptation to illness. Correlation ranged from weak to moderate magnitude between the IDCV total score, and its factors (3 and 4), and between IDCV and the IQV, pointing to divergent validity. Strong magnitude correlation was verified between the IDCV total score and the IEQ; weak to moderate magnitude was verified between factors 1, 2 and 3 of the IDCV and the IEQ, and among the IDCV total score (its factors 2 and 3) and General Measure of Impact of Illness to, pointing to criterion validity. It was observed a Cronbach's Alpha of 0,74, which points to the internal consistency of instrument. The results of the current study confirm the construct and criterion validity, and points to internal consistency of the IDCV. Future studies are necessary to confirm its reliability and to provide more informations for a better understanding of the meaning of the dimensions in the impact measured by the IDCV, as well as to evaluate the response ofthe instrument to health interventions. Although this study presents characteristics that do not allow the generalization of the results and a strong recommendation for using the IDCV, it can be affirmed that this instrument represents an important first step in the efforts for an understanding of the experience with the vale heart disease and the effectiveness of the health interventions implemented in this context / Mestrado / Enfermagem e Trabalho / Mestre em Enfermagem

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/310822
Date24 February 2005
CreatorsPadilha, Kátia Melissa, 1978-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Gallani, Maria Cecilia Bueno Jayme, 1966-, Kimura, Miako, Alexandre, Neusa Maria Costa
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Enfermagem
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format155p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds