Desenvolvimento de parafuso de interferência bioabsorvível para cirurgia de joelho em PLDL (poli ácido lático) e compósito PLDL + βTCP (beta trifosfato de cálcio) / Development of bioabsorbable interference screw for knee surgery in PLDL (poly L,DL-lactic acid) and composite PLDL / βTCP (Beta tricalcium phosphate)

Made available in DSpace on 2015-06-17T19:34:39Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-01-12. Added 1 bitstream(s) on 2015-06-18T12:48:27Z : No. of bitstreams: 1
000825246.pdf: 3464292 bytes, checksum: 907652ea25dcfa1a9a30ba9ee22fa099 (MD5) / O parafuso de interferência é o dispositivo de fixação mais usados em cirurgias de reconstrução ligamentar de joelho. O uso dos polímeros bioabsorvíveis está sendo cada vez mais utilizados nesta aplicação, devido suas vantagens relacionadas à excelente biocompatibilidade, bioabsorção, integração do enxerto/osso e também facilidade na revisão cirúrgica. O presente estudo tem por objetivo tem por objetivo o desenvolvimento de um parafuso de interferência bioabsorvível fabricado através do processo de injeção em dois polímeros bioabsorvíveis: PLDL (Poli L-D-ácido lático) e um compósito de PLDL+30% TCP (β Trifosfato de Cálcio). Para o desenvolvimento do projeto do produto foi usado um programa de análise estrutural por elementos finitos, de forma a obter a melhor geometria do encaixe de ferramenta. Através dos estudos de simulação por elementos finitos foi possível selecionar a geometria com maior resistência mecânica levando em conta o esforço de torção e além disso foi possível analisar a influência de furos transversais nas tensões mecânicas geradas pelos esforços de torção. Após a definição da melhor geometria, foram fabricadas amostras dos parafusos com os dois polímeros selecionados, os quais foram esterilizados por ETO (Óxido de etileno). Foram realizados testes mecânicos de torque inserção e torque de ruptura. A resistência mecânica do parafuso foi avaliada através da comparação entre os valores do torque de inserção comparando-se com o torque máximo de ruptura. Para contribuir o estudo foi executado teste de degradação in vitro, durante um período de 180 dias, onde foi avaliada a perda de massa dos implantes, resistência mecânica e queda do peso molecular dos implantes. Logo foi possível avaliar o compartamento mecânico dos implantes em degradação comparando-os com os requerimentos da aplicação. Pode-se observar que a degradação molecular do implante ao longo dos... / The interference screw is the fixation device most selected for Knee ligament reconstruction surgeries. The use of Bioabsorbable polymers in interference screws for this application is increasing due it has advantages like excellent biocompatibility, bioabsorption, good integration between graft / bone and also facility in the surgical revision. The aims of the present study were to develop a bioabsorbable interference screw manufactured by the injection moulding process with two distinct polymeric materials: PLDL, Poly(L,DL-Latic acid) and a composite PLDL + 30% TCP (β Tricalcium phosphate). A program for structural analysis by finite elements was used in the development of the screw design, in the intend to make the best geometry fit for the tool. Trough the study by finite elements simulation it was possible to chose the geometry with higher mechanical resistance taking in the account the torsion effort and analyse the influence of transversals holes in the mechanical tensions made by the torque efforts. After the definition of the best geometry, samples of the screw were manufactured with the two selected polymers, sterilized with ETO (ethylene oxide). Were performed mechanical tests, insertion test and torque to break. The mechanical strenght of the screw was evaluated through the comparison between the values of insertion torque and maximum rupture. In addition, a in vitro, degradation test was performed over a period of 180 year days. It was observed, the weight loss, mechanical strength of the implants was evaluated, and molecular weight drops of the implants. Therefore it was possible to evaluate the mechanical behavior in degradation and compare with the application requirements. It can be observed that the raise of the molecular degradation of the implant along the months had as result a loss of the mechanical resistance of the screw, ina slowly and gradual way for the PLDL material, yet the composite material (PLDL+TCP)...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/124038
Date12 January 2015
CreatorsSantos, Alex Eugênio dos [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Sanchez, Luiz Eduardo de Ângelo [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format101 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0029 seconds