Previous issue date: 2013-12-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Devido a sua localiza??o no continente, a cidade de Natal (Rio Grande do Norte, Brasil) recebe ventos constantes, o que a torna mundialmente conhecida como a cidade que tem uma boa qualidade do ar. No entanto, faltam estudos que comprovem este t?tulo. Mesmo Natal n?o sendo uma cidade industrializada, est? em pleno desenvolvimento s?cio-econ?mico, e isto implica em um crescimento do poder aquisitivo da popula??o, como tamb?m no conseq?ente aumento da frota de ve?culos automotores. Com isso, ? poss?vel se prever uma evolu??o nas emiss?es veiculares, acarretando na crescente preocupa??o com a polui??o atmosf?rica, sabendo que esta pode causar danos ? sa?de humana e ao meio ambiente. O presente trabalho teve como objetivo avaliar qualidade do ar atmosf?rico de regi?o urbana da cidade de Natal, capital do estado do Rio Grande do Norte (latitude 5?49?29?? sul e longitude 35?13?34?? oeste), visando determina??o da concentra??o dos metais Mn, Ni, Cu, As, Cd e Pb no Material Particulado (PM10 e PM2,5) do ar atmosf?rico na ?rea urbana da cidade do natal. O per?odo de amostragem para o estudo compreendeu a aquisi??o de dados de Janeiro a Dezembro de 2012. Os filtros contendo material particulado foram selecionados de seis em sem dias e digeridos. As amostras digeridas foram analisadas por Espectrometria de Massa com Plasma Indutivamente Acoplado (ICP-MS). Para a concentra??o do material particulado as m?dias mensais variaram de 8,92 a 19,80 ?g/m3 para o PM10 e de 2,84 a 7,89 ?g/m3 para o MP2,5. Sendo assim, para o per?odo do estudo, a concentra??o de MP10, n?o ultrapassou em nenhum momento os valores definidos pela legisla??o vigente (CONAMA 03/90), que estabelece como padr?o de qualidade do ar a concentra??o para MP10, o valor de 150 ?g/m3, para um per?odo de 24 h e para longos per?odos a m?dia aritm?tica anual de 50 ?g/m3. E as concentra??es de MP2,5 estiveram em acordo como o padr?o estabelecido pela EPA (12 ?g/m?). As m?dias das concentra??es dos metais para o MP10, variaram de 0,12 a 6,20 ng.m-3 e para o MP2,5 de 0,18 a 5,81 ng.m-3 sendo que as maiores m?dias encontradas foram para os elementos Pb, Mn e Cu. Os elementos V, Cr, Ni, As e Cd apresentaram m?dias mais baixas. No entanto, em nenhum caso as concentra??es dos metais ultrapassaram os valores regulamentados internacionalmente pela Ag?ncia de Prote??o Ambiental dos Estados Unidos - EPA, Organiza??o Mundial da Sa?de - WHO e Uni?o Europ?ia. / This study aimed to assess ambient air quality in a urban area of Natal, capital of Rio Grande
do Norte (latitude 5?49'29 '' S and longitude 35?13'34'' W), aiming to determine the metals
concentration in particulate matter (PM10 and PM2,5) of atmospheric air in the urban area o the
Natal city. The sampling period for the study consisted of data acquisition from January to
December 2012. Samples were collected on glass fiber filters by means of two large volumes
samplers, one for PM2,5 (AGV PM 2,5) and another for PM10 (PM10 AGV). Monthly averages
ranged from 8.92 to 19.80 ?g.m-3
, where the annual average was 16,21 ?g.m-3
for PM10 and
PM2,5 monthly averages ranged from 2,84 to 7,89 ?g.m
-3
, with an annual average of 5,61
?g.m-3
. The results of PM2,5 and PM10 concentrations were related meteorological variables
and for information on the effects of these variables on the concentration of PM, an
exploratory analysis of the data using Principal Component Analysis (PCA) was performed.
The results of the PCA showed that with increasing barometric pressure, the direction of the
winds, the rainfall and relative humidity decreases the concentration of PM and the variable
weekday little influence compared the meteorological variables. Filters containing particulate
matter were selected in six days and subjected to microwave digestion. After digestion
samples were analyzed by with Inductively Coupled Plasma Mass Spectrometry (ICP-MS).
The concentrations for heavy metals Vanadium, Chromium, Manganese, Nickel, Copper,
Arsenic and lead were determined. The highest concentrations of metals were for Pb and Cu,
whose average PM10 values were, respectively, 5,34 and 2,34 ng.m-3
and PM2,5 4,68 and 2,95
ng.m-3
. Concentrations for metals V, Cr, Mn, Ni, and Cd were respectively 0,13, 0,39, 0,48,
0,45 and 0,03 ng.m-3
for PM10 fraction and PM2,5 fraction, 0,05, 0,10, 0,10, 0,34 and 0,01
ng.m-3. The concentration for As was null for the two fractions
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/19470 |
Date | 17 December 2013 |
Creators | Albuquerque, Mariana Helena de Oliveira |
Contributors | 42314070453, http://lattes.cnpq.br/1595902438130772, Moraes, Edgar Perin, 13563054827, http://lattes.cnpq.br/0705932816454884, Castro, Francisco Laerte de, 77862589491, http://lattes.cnpq.br/2913544384537886, Fernandes, Glauber Jos? Turolla, Fernandes J?nior, Valter Jos? |
Publisher | Universidade Federal do Rio Grande do Norte, PROGRAMA DE P?S-GRADUA??O EM QU?MICA, UFRN, Brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds