Return to search

Estudo eletromiografico das partes anterior media e posterior do musculo temporal na cinetica mandibular / Electromyographic study of anterior, medium and posterior parts in mandibular cinetic

Orientador: Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T05:46:35Z (GMT). No. of bitstreams: 1
Nagae_MirianHideko_D.pdf: 2106421 bytes, checksum: 2ee2d856ed2843157f40629bebd6ed09 (MD5)
Previous issue date: 2007 / Resumo: Este estudo teve por finalidade investigar por meio da eletromiografia de superfície a atividade elétrica, unilateral direita das partes anterior, média e posterior do músculo temporal, na situação postural de repouso mandibular, durante a contração voluntária máxima (CVM) e nos movimentos de abaixamento leve e máximo mandibular, propulsão, retropulsão, protrusão, retrusão, lateralidade homolateral direita e lateralidade contralateral. Foram investigados 21 sujeitos, gênero masculino, Classe I de Angle, com faixa etária entre 18 e 40 anos, tricotomizados, sem história de Disfunção Temporomandibular, bruxismo e/ou apertamento dental. O equipamento utilizado foi o eletromiógrafo Myosystem I da DataHominis Tecnologia Ltda, 12 canais, 12 bites de resolução, CMRR de 112dB @ 60Hz com módulo de conexão para eletrodos passivos, ajuste para ganho entre 1 a 16.000 vezes, filtro Butterworth, passa alta de 15Hz e passa baixa de 1KHz, placa conversora A/D, modelo PCI-DAS 1200, Myosystem da Prosecon Ltda. O eletrodo de referência foi fixado junto ao osso externo do voluntário e para a captação dos sinais foi utilizado eletrodo de superfície passivo, descartável, bipolar da NoraxonÒ USA Inc, modelo 272, formato circular, diâmetro de 1cm, de Ag/AgCl, com distância intereletrodo pré-fixado de 1cm, acoplados a um pré-amplificador da Lynx Tecnologia, formando um circuito correspondente a um transdutor diferencial. Para processamento e análise dos sinais foi utilizado o software Myosystem-BR1 da DataHominis Tecnologia Ltda (versão 2.9). Os sinais foram captados com os voluntários sentados, com o plano de Frankfürt paralelo ao solo, olhos abertos e fixos no horizonte. A freqüência de amostragem para a captação do sinal foi de 2000Hz e a duração de cada situação analisada foi de 5 segundos. Para análise do sinal eletromiográfico foi calculado o valor do Root Means Square (RMS). Na situação postural de repouso os valores obtidos não foram considerados estatisticamente significativos para a atividade elétrica das partes anterior, média e posterior do músculo temporal, de acordo com os testes de Shapiro-Wilk (1965), coeficiente de assimetria e teste do sinal. A função de correlação entre as partes anterior, média e posterior do músculo temporal foi considerada estatisticamente significativa na posição postural de repouso, para as partes média e posterior (63%); na contração voluntária máxima, para as partes anterior e posterior(74%); no abaixamento leve mandibular, para as partes média e posterior (63%); no abaixamento máximo mandibular, para as partes anterior e média (68%), partes média e posterior (67%) e partes anterior e posterior (61%); na propulsão mandibular, para as partes anterior e média (67%); na protrusão mandibular, para as partes anterior e média (67%) e partes média e posterior (60%); na retrusão mandibular, para as partes média e posterior (62%), anterior e média (61%) e anterior e posterior (60%); na lateralidade mandibular homolateral direita, para as partes média e posterior (76%); na lateralidade mandibular contralateral, para as partes média e posterior (70%) e somente para retropulsão mandibular não houve correlação estatisticamente significativa para nenhuma das partes / Abstract: This study aimed at investigating through surface myography the electrical activity of front, middle, and back parts of temporal muscle, situation of resting jaw, during maximal voluntary contraction (MVC), and in the movements of slight and maximal mandibular drop, propulsion, retropulsion, protusion, retrusion, right homolateral laterality, and contralateral laterality. There were 21 subjects investigated, male gender, Angle Class I, age group ranging from 18 to 40 years old, tricotomized, showing no history of Temporomandibular, bruxism, and/or dental clenching. The equipment used was Myosystem I electromyographer by DataHominis Tecnologia Ltda, with 12 channels, resolution of 12 bytes, CMRR of 112dB @ 60Hz with connection module for passive electrodes, adjustment para ganho between 1 to16.000 times, Butterworth filter, 15Hz high pass, and 1KHz low pass; A/D converting plaque, model PCI-DAS 1200 , Myosystem by Prosecon Ltda. Reference electrode was fixed next to the volunteer¿s external bone, and to pick up the signal a passive surface electrode was used, dischargeable, bipolar by NoraxonÒ USA Inc, model 272, circular shaped, 1cm in diameter, of Ag/AgCl, with distance between the electrodes pre-fixed in 1cm, coupled together to a pre-amplifier by Lynx Tecnologia, forming a circuit corresponding to a differential transducer. To process and analyze signals it was used the Myosystem-BR1 software by DataHominis Tecnologia Ltda (version 2.9). The signals were picked up with volunteers sitting, with the Frankfurt plan parallel to the floor, open eyes and horizon gazing. The sampling frequency to pick up the signal was of 2000Hz, and the duration of each event was of 5 seconds. For the electromyography signal analysis it was calculated the Root Means Square (RMS) value. At the resting posture position the values obtained were not considered statistically significant for the electrical activity of the front, middle, and back parts of the temporal muscle, according to Shapiro-Wilk tests (1965), asymmetry coefficient, and signal test. The correlation function between front, middle, and back parts of temporal muscle was considered statistically significant at the resting posture situation, to the middle and back parts (63%); at the maximal voluntary contraction , to the front and back parts (74%); at the slight mandibular drop, to the middle and back parts (63%); at the maximal mandibular drop, to the front and middle parts (68%), back and middle parts (67%),and front and back parts (61%); at the mandibular propulsion, to the front and middle parts (67%); at the mandibular protusion, to the front and middle parts (67%), and back and middle parts (60%); at the mandibular retrusion, to the middle and back parts (62%), front and middle (61%), and front and back (60%); at the right mandibular homolateral laterality, to the middle and back parts (76%); at the mandibular contralateral laterality, to the middle and back parts (70%), and only to the mandibular retropulsion there was no correlation statistically significant to any of the parts / Doutorado / Anatomia / Doutor em Biologia Buco-Dental

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288798
Date18 February 2007
CreatorsNagae, Mirian Hideko, 1965-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bérzin, Fausto, 1940-, Coury, Helenice Jane Cote Gil, Grossmann, Eduardo, Lima, Maria Cecilia Marconi Pinheiro, Sartini Filho, Raul
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Biologia Buco-Dental
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format109p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds