Return to search

Estacas submetidas a esforços horizontais em solos colapsiveis do interior de São Paulo, nas condições natural, melhorada e inundada / Horizontally loaded piles in collapsible soils of the interior of the state of São Paulo, under the conditions of natural humidity, improved soil and pre-flooded soil

Orientador: David de Carvalho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-09T05:45:20Z (GMT). No. of bitstreams: 1
MirandaJunior_Gentil_D.pdf: 36304791 bytes, checksum: 88909d0a8735e0e6ebf6251c718ba4cb (MD5)
Previous issue date: 2006 / Resumo: O problema de estacas carregadas horizontalmente no topo é freqüente em obras de construção civil e há uma reduzida bibliografia sobre os parâmetros a serem adotados em projetos. Uma situação mais crítica é a de estacas carregadas horizontalmente em solos de alta porosidade, não saturados e colapsíveis. Os objetivos deste trabalho são: (1) proporcionar subsídios para o projeto de fundações com carregamento horizontal, chamando a atenção para o danoso efeito de uma inundação de um solo colapsível; (2) fornecer valores do coeficiente de reação horizontal ('n IND. h') para uma argila silto arenosa de alta porosidade, solo de diabásio, comum na região de Campinas, para condições de umidade natural, solo pré-inundado, solo melhorado com solocimento e solo-cimento pré-inundado; (3) compararos valores obtidos com valores de 'n IND. h' para solos freqüentemente encontrados no interior do Estado de São Paulo e em outras regiões do Brasil; (4) propor uma melhoria das condições do sistema solo-estaca através da troca do solo ao redor do topo da estaca por solo-cimento compactado. Para a análise deste problema, foram realizadas vinte e uma provas de cargas horizontais no Campo Experimental de Fundações da Unicamp, em catorze estacas de quatro tipos, nas quatro condições de solo citadas acima. E foram analisadas outras provas de carga realizadas em Campos Experimentais do Estado de São Paulo, todos localizados em regiões com solos superficiais com características desfavoráveis ao carregamento horizontal. Comparam-se valores do coeficiente de reação horizontal do solo ('n IND. h') para diferentes
condições do solo, destacando-se a importância de se obter parâmetros do solo regionalmente. Os principais resultados encontrados foram, além dos valores de coeficiente de reação horizontal para o solo de basalto do local e a compilação de valores para solos de alta porosidade de outras regiões - encontrando-se valores diferentes dos propostos na bibliografia -, a acentuada redução do 'n IND. h' (valoresem tomo de 40 vezes menores) ocasionada pela préinundação
do solo, o acentuado aumento do 'n IND. h'(valores em média 5 vezes maiores) com a melhora do solo através do solo-cimento compactado,e a redução do 'n IND. h' com a pré-inundação do solo-cimento (valores em média 7 vezes menores). Nota-se que a redução devido à préinundação do solo-cimento é bem inferior a da pré-inundaçãodo solo na umidade natural. Conclui-se que, num projeto onde há a atuação de esforços horizontais e presença de solo colapsível, é necessário contar com a possibilidade de uma inundação do solo, tomar medidas preventivas contra a mesma e utilizar parâmetros do solo adequados. Ou adotar soluções de melhoria do solo, como a utilização do solo-cimento compactado ao redor da cabeça da estaca, que também podem ser adotadas em casos de baixa resistência do solo superficial (seja o solo colapsível ou não) / Abstract: The problem with piles loaded horizontally at the top is frequently met in civil construction projects and there is a reduced bibliography on the parameters to be adopted in designoA more critical situation is that of horizontally loaded piles in high porosity, non saturated and collapsible soils. The objectives of this paper are: (1) produce subsidies for the design of foundations with horizontalloads, calling attention to the damaging effect of flooding on a collapsible soil; (2) supply values for the horizontal reaction coefficient ('n IND. h') for the soil of the Experimental Field at Unicamp, for the conditions of natural humidity, pre-flooded soil, soil improved with soil-cement and pre-flooded soil-cement; (3) compare values of nh for the soils frequently found in the interior of the State of São Paulo and in other regions in Brazil; (4) propose an improvement in the conditions of the soil-pile system soils by changing the soil around the top of the pile for compacted soil-cement. To analyze this problem, twenty one horizontal loading tests were made in the Experimental Foundation Field at Feagri-Unicamp, on fourteen piles of four types, under the four soil conditions mentioned above. Other loading tests made in Experimental Fields in the State of São Paulo were analyzed, alI of them located in regions with surface soils with unfavorable characteristics for horizontal loading. The coefficients of horizontal soil reaction ('n IND. h') for different soil conditions are compared, emphasizing the importance of obtaining regional soil parameters. The principal results found were, besides the values for the coefficient of horizontal reaction for the basalt soil at the location and the compilation of values for high porosity soils of other regions - encountering different values from °those proposed in literature - an accentuated reduction of nh (values around 40 times less) caused by the pre-flooding of the
soil, the accentuated increase in 'n IND. h' values (as a mean, 5 times greater) with the soil improvement by compacted soil-cement and the reduction in 'n IND. h' with pre-flooding of the soilcement (mean values 7 times smaller). It is seen that the reduction due to pre-flooding of the soil-cement is much less than that for pre-flooding the soil at natural humidity. One concludes that in a project where horizontal forces act and in collapsible soil, one must count with the possibility of soil flooding, taking preventive measures against this and using adequate soil parameters or, adopt solutions for soil improvement, as by using compacted soil-cement around the pile head, a procedure which can also be adopted in cases of low surface soil resistance (collapsible soil or not) / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/257060
Date12 November 2006
CreatorsMiranda Junior, Gentil
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Carvalho, David de, 1955-, Carvalho, David de, 1931-, Ranzini, Stelvio Milton Teixeira, Ferreira, Claudio Vidrih, Souza, Adriano, Miguel, Miriam Gonçalves
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Agrícola, Programa de Pós-Graduação em Engenharia Agrícola
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format303f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds