Return to search

Cardiotocografia ante-parto e percepção materna dos movimentos fetais na avaliação do bem estar fetal em gestantes diabeticas

Orientador: Anibal Faundes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-22T05:05:49Z (GMT). No. of bitstreams: 1
Pereira_BelmiroGoncalves_D.pdf: 1535645 bytes, checksum: 0d0fcf1ee8c166a1310bd7bab516e569 (MD5)
Previous issue date: 1996 / Resumo: A avaliação das condições fetais em diabéticas continua sendo fator preocupante na assistência pré-natal. O diagnóstico correto das provas de vitalidade fetal ainda é problema, principalmente quando se trata de permitir que a gestação prossiga. Estudamos o "Nonstress test" (NST) de 214 gestações de diabéticas atendidas no Pré-Natal Especializado (PNE) do Centro de Atenção Integral à Saúde da Mulher (CAISM), entre junho de 1988 e maio de 1996. Estudamos também o Estímulo Acústico (EA), isoladamente, e depois associado ao NST. Classificamos estes exames como reativos (R), hiporreativos (HR) ou não reativos (NR), de acordo com a variação da freqüência cardíaca aos movimentos fetais ou ao EA. Avaliamos ainda a percepção materna dos movimentos fetais (PMMF) de 209 dessas gestações, classificados como "normais" quando maiores que sete em até uma hora e "anormais' se isso não ocorreu. Comparamos estas variáveis (independentes) com os resultados perinatais, como sinais de sofrimento fetal (SF) à prova de Pose ou intra-parto, Apgar de 10 e 50 minutos de vida menor que sete e diagnóstico neonatal de anóxia (variáveis dependentes). Calculamos os valores de sensibilidade, especificidade, valor preditivo positivo (VPP) e valor preditivo negativo (VPN). Posteriormente, controlamos tais resultados pelas variáveis hipertensão, controle metabólico e idade gestacional. As diferenças estatísticas for~m avaliadas pelo teste de X2 para comparação de testes de diagnóstico!, e considerou-se como significativa a diferença que correspondeu a p<0,05. Cerca de 18% dos NST foram NR e cerca de 50% deles se tornaram reativos após o EA. Estes exames apresentaram boa especificidade, próxima a 90% e VPN entre 90 e 100%, enquanto a sensibilidade e VPP variaram bastante, dependendo da condição que se pretendia predizer. Não foram encontradas diferenças estatísticas da- capacidade de diagnóstico para variáveis perinatais entre a PMMF e os métodos monitorizados, exceto para SF que foi melhor diagnosticado pelo NSTIEA. Não foram encontradas diferenças quando se controlou por hipertensão, controle metabólico e idade gestacional / Abstract: Fetal well-being in pregnant diabetics is a continous concern during ante-natal care. The correct diagnosis of fetal surveillance tests remain a problem, considering the perspective of allowing pregnancy to continue. Non-stress test (NST) was studied on 214 diabetic pregnancies at the High Risk Prenatal Care at the Centro de Atenção Integral à Saúde da Mulher (CAISM), between June 1988 and May 1996. Vibro-acustic Stimulation (EA) was also studied, either isolated or in association to NST. Tests were classified as reactive (R), hiporeactive (HR) or. not-reactive (NR), according to the characteristics of fetal heart frequency variability in response to fetal movements or EA. Maternal perception of fetal movements (PMMF) of 209 of these pregnancies was also studied. This test was classified as normal when seven or more movements were perceived by the mother within one hour and abnormal when less than seven fetal movements were perceived within the same period of observation. The results of these tests (independent variables) were compared with the signs of fetal distress (SF) during labor or a occitocin-induced contraction stress test, with Apgar scores bellow seven at the 1st and 5th minutes of life or with neonatal diagnosis of hipoxia (dependent variables). Sensitivity, specificity, positive predictive value (VPP) and negative predictive value (VPN) were calculated. These results were then controlled bythe variables: hypertension, metabolic control and gestacional age. Statistical" differences between diagnostic tests, were calculated by Chi-square test and considered significative for p<Ok,05. Some 18% of the NST tests were NR and 50% of them became R after EA. These tests had specificity around 90% and VPN between 90% and 100%, whereas sensitivity and VPP varied depending on the condition evaluated. No statistical differences were observed for the diagnosis of perinatal variables between the PMMF and electrically monitored methods, except for fetal distress that was better diagnosed by NST/EA. No differences were observed when hypertension, metabolic control or gestational age were used as controlled variables / Doutorado / Tocoginecologia / Doutor em Tocoginecologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/308227
Date27 November 1996
CreatorsPereira, Belmiro Gonçalves, 1955-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Faúndes, Anibal, 1931-
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Tocoginecologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format112 f., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds