Return to search

Relação entre a duração do estímulo e lesão de miócitos cardíacos por campos elétricos de alta intensidade = Relation between stimulus duration and injury to cardiac myocytes by high electric fields / Relation between stimulus duration and injury to cardiac myocytes by high electric fields

Orientador: Pedro Xavier de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-24T14:24:09Z (GMT). No. of bitstreams: 1
Prado_LuizaNaiaraSiqueirado_M.pdf: 1448858 bytes, checksum: 14894261e1f5acfa5c112a5bd731af13 (MD5)
Previous issue date: 2014 / Resumo: Apesar de a aplicação de campos elétricos de alta intensidade ser atualmente a única terapia disponível para interromper a fibrilação ventricular, esse processo pode causar lesões às células cardíacas, prejudicando sua contratilidade. Neste estudo, aplicamos pulsos elétricos de alta intensidade a miócitos isolados de ratos Wistar adultos. Obtivemos as curvas de letalidade por meio de análise de sobrevivência, que foram usadas para determinar a intensidade de campo necessária para matar 50% das células (EL50) e com esses valores obtivemos a curva de intensidade-duração (IxD) para letalidade para 10 durações diferentes: 0,1; 0,2; 0,5; 1; 3; 5; 10; 20; 35 e 70 ms. Também obtivemos a curva IxD para excitação celular, por meio dos valores de média ± erro padrão da média para a intensidade de campo limiar de excitação para todas as durações, e obtivemos uma relação entre letalidade e excitação em função da duração do pulso, chamada de Fator de Segurança (FS), um indicador de segurança estimulatória. Essa curva foi determinada a partir da divisão entre os pontos das curvas IxD de letalidade e excitação. Observamos que quanto me-nor a duração de pulso, maior a intensidade de campo que causa morte celular. Ao contrário do que se esperava, o maior valor de FS não correspondeu à menor duração utilizada (0,1 ms), mas sim à duração de 0,5 ms. Como o limiar de desfibrilação foi descrito como dependente da duração do pulso aplicado, nossos resultados indicam que o uso de estímulos com duração mais curta - em vez da duração tipicamente usada na clínica, de 10 ms - pode diminuir as lesões celulares, e, portanto, aumentar a efetividade da desfibrilação / Abstract: Although high intensity electric fields application is currently the only effective therapy available to terminate ventricular fibrillation, it may cause injury to cardiac cells, impairing their contractility. In this study we applied high electric field pulses with different durations to isolated rat ventricular myocytes. We obtained lethality curves by survival analysis, which were used to determine the value of applied electric field necessary to kill 50% of cells (EL50) and plotted a strength-duration (IxD) curve for lethality with 10 different durations: 0.1, 0.2, 0.5, 1, 3, 5, 10, 20, 35 and 70 ms. For the same durations we also obtained an IxD curve for excitation and established an indicator for stimulatory safeness, named Safety Factor (FS), as the ratio between the points on the IxD curve for lethality and the one for excitation. We found that the lower the pulse duration, the higher the electric field intensity required to cell death. Contrary to expecta-tions, the highest FS value does not correspond to the lowest pulse duration but to the one of 0.5 ms. As defibrillation threshold has been described as duration dependent, our results imply that the use of shorter stimulus duration - instead of the one typically used in the clinic (10 ms) - may decrease electric cell damage, therefore increasing defibrillation effectiveness / Mestrado / Engenharia Biomedica / Mestra em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259737
Date24 August 2018
CreatorsPrado, Luiza Naiara Siqueira do, 1989-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Oliveira, Pedro Xavier de, 1975-, Mota, Alexandre de Assis, Bassani, Rosana Almada
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format44 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0035 seconds