Return to search

Sensores eletroquímicos para o fármaco cisplatina como ferramenta biotecnológica no monitoramento clínico, metabólico e ambiental

Made available in DSpace on 2016-08-12T18:48:48Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-09-10. Added 1 bitstream(s) on 2016-08-12T18:51:06Z : No. of bitstreams: 1
000857407_20170910.pdf: 828849 bytes, checksum: 3d1d6ca67089dd4d215ef86e6e490933 (MD5) Bitstreams deleted on 2017-09-11T13:55:54Z: 000857407_20170910.pdf,. Added 1 bitstream(s) on 2017-09-11T13:56:49Z : No. of bitstreams: 1
000857407.pdf: 2331591 bytes, checksum: 1fa5b1caae874d52e97bccd59a46ce2f (MD5) / Neste trabalho é apresentado o desenvolvimento de dois sensores eletroquímicos modificados para determinação sensível e seletiva de cisplatina, um dos fármacos mais frequentemente utilizados no tratamento oncológico de diversos tipos de patologias tumorais cancerosas. O primeiro sensor foi desenvolvido a base de pasta de carbono modificado com a enzima glutationa-s-transferase (GST). O biossensor é baseado na resposta inibitória da atividade enzimática da enzima GST devido à adição do fármaco cisplatina. Glutationa reduzida (GSH) e 1-cloro-2,4-dinitrobenzeno foram utilizados como substratos para a enzima GST, os quais foram adicionados na concentração de 1,0 x 10-3 mol L-1 na cela de medida. As técnicas utilizadas para a caracterização do sistema foram espectroscopia de infravermelho, voltametria cíclica e impedância eletroquímica. Os resultados quantitativos daquelas interações foram obtidos usando VOQ, observando-se uma resposta linear entre 50 e 140 μmol L-1 de cisplatina e limite de detecção de 8,8 μmol L-1 de cisplatina. O biossensor apresentou uma boa repetibilidade intra-dia com um desvio padrão relativo de 4,2% avaliando quatro curvas analíticas. O uso da pasta de carbono ofereceu a possibilidade de uma simples, rápida e eficiente renovação da camada de superfície do eletrodo, o que permitiu a utilização da mesma pasta em várias medidas durante um longo período de tempo. Adicionalmente, foi desenvolvido um sensor não enzimático no monitoramento da cisplatina usando eletrodos impressos de carbono (SPCE, screen-printed carbon electrodes) modificados com nanotubos de carbono de multiplas paredes funcionalizados com grupos carboxila (MWCNT-COOH.SPCE) da DROPSENS® (SDS 110CNT). Com o propósito de avaliar a influência dos nanotubos de carbono na resposta do sensor de cisplatina foi utilisada a técnica de voltametria cíclica. O uso do surfactante dodecilsulfato... / This thesis presents the development of two electrochemical sensors for the sensitive and selective detection of cisplatin, one of the drugs most frequently used in the oncologic treatment of several cancer tumor pathologies. The first was a biosensor based on carbon paste modified with the enzyme glutathione-s-transferase (GST). The biosensing was based on the inhibitory response of the enzymatic activity of GST due to the addition of the drug cisplatin. Reduced glutathione (GSH) and 1-chloro-2,4-dinitrobenzene were used as substrates for the GST enzyme, and were added at the concentration of 1.0 x 10-3 mol L-1 in the measuring cell. The techniques used for the characterization of the system were infrared spectroscopy, cyclic voltammetry and electrochemical impedance. The quantitative results of those interactions, obtained by square wave voltammetry (SWV) and differential pulse with adsorptive stripping voltammetry were very similar, and very promising for the analysis of cisplatin. The biosensor showed, using SWV, a linear response between 50 and 140 μmol L-1 of cisplatin. The detection limit was 8.8 μmol L-1 of cisplatin. In the intra-day repeatability studies, the relative standard deviation was 4.2%, from the analysis of four analytical curves, showing the repetitiveness of the electrochemical response of the proposed sensor. The use of the carbon paste offered the possibility of the simple, quick and efficient renewal of the surface layer of the electrode, which allowed the use of the same paste for several measurements during a long period of time. Additionally, a non-enzymatic sensor was developed for the monitoring of cisplatin using screen-printed carbon electrodes (SPCE, screen-printed carbon electrodes), functionalized with multi-walled carbon nanotubes and factory modified with carboxyl groups (MWCNT-COOH) acquired from DROPSENS® (SDS 110CNT). The electrochemical characterization...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/143010
Date10 September 2015
CreatorsMaterón Vásquez, Elsa María [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Sotomayor, María del Pilas Taboada [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format129 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0031 seconds