Return to search

Simulação do campo acústico de transdutores ultrassônicos de alta frequência do tipo array anular com e sem espaçamento entre anéis / Simulation of acoustic field of high frequency annular array transducers with and without kerf

Orientador: Vera Lúcia da Silveira Nantes Button / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-22T22:55:05Z (GMT). No. of bitstreams: 1
Nascimento_ValeriaMonteirodo_D.pdf: 6068450 bytes, checksum: 537e820daa45af6d8d50ccee4ad135e5 (MD5)
Previous issue date: 2013 / Resumo: Para observar o efeito no campo acústico dos diversos parâmetros de configuração do projeto de um transdutor ultrassônico, foram simuladas várias configurações de transdutor de alta frequência (5 a 50 MHz), tipo array anular, com kerf e kerfless, de cerâmica PZT-5H e de filme de PVDF. Transdutores com configurações de três, quatro, cinco e seis anéis, em que os anéis possuíam a mesma largura foram simulados com elemento ativo de cerâmica. E transdutores com cinco, seis, sete, oito e dez anéis de mesma área, com separação física entre os elementos (kerf) e sem separação física entre os elementos (kerfless) foram simulados com elementos piezoelétricos de cerâmica PZT-5H e filme de PVDF. Também foram testados materiais de diferentes impedâncias acústicas nas camadas de retaguarda (epóxi, epóxi e Araldite, ferro, tungstênio, alumina e madeira), foram usadas diversas funções de excitação dos elementos piezoelétricos (Blackman, Wavelet, Gauss, Seno, Step) em frequências variadas, além de se acionar os diversos elementos anelares isoladamente, em grupos e com atraso temporal. O objetivo das simulações realizadas foi determinar a melhor configuração de um transdutor array anular, quanto ao número de anéis, espaçamento entre eles e necessidade ou não de separação física entre os elementos, levando-se em conta a complexidade de construção e as características do campo acústico gerado. Para isso, os parâmetros observados no campo acústico foram à amplitude do pico, a amplitude média de pressão, a profundidade do campo, a colimação do feixe principal e a presença de lóbulos laterais. Outros parâmetros observados foram à tensão e a carga nos elementos. Os resultados obtidos nas simulações dos transdutores arrays circulares, feitas com o programa PZFlex®, foram processados no Matlab® para visualização do campo acústico e extração de parâmetros. As funções de transferência do sinal de excitação e da resposta à estimulação foram calculadas com os dados obtidos. O transdutor kerfless foi simulado no PZFlex® e seus resultados processados no Matlab®, para comparar com os resultados do transdutor com kerf de mesma configuração. Os resultados das simulações mostraram que o campo acústico neste tipo de transdutor, array anular, tem a região de campo distante começando bem próximo à face do transdutor. A camada de retaguarda de epóxi e Araldite® apresentaram valores mais elevados de amplitude do campo acústico. A função de excitação foi Wavelet na frequência de 30 MHz devido às restrições da relação diâmetro / espessura da cerâmica PZT-5H. O transdutor kerfless apresentou um campo acústico com as mesmas características do transdutor com kerf, com a vantagem de sua construção ser mais simples / Abstract: In order to observe the effect of ultrasound transducers parameters configurations in an acoustic field, simulations were made in some different configuration of an annular array ultrasound transducer in high frequency (5 to 50 MHz), kerf and kerfless, with active element of PZT - 5H ceramic or PVDF. The transducers configurations simulated were three, four, five and six annulus, with the same width, and the active element was PZT-5H. And transducers with five, six, seven, eight and ten annulus, with the same area, with and without physical separation between the elements had been simulated with active element of PZT-5H ceramics or PVDF. The materials of backing layer (epoxy, epoxy and Araldite, iron, tungsten, alumina and wood dust) with different impedance were also be tested, and a variety of excited functions (Blackman, Wavelet, Gauss, Sine, Step), in different frequencies, and also with time delay in active elements. The objective of this simulation was to find out the better configuration of an annular array ultrasound transducer in high frequency, the number of annulus, spacing between them, the area, the transducer is kerf or kerfless, considering the build complexity and the characteristics of acoustic field. To do this, the peak amplitude, the depth and the average amplitude of the acoustic field was measured. The charge and the voltage in the elements were also observed. The results obtained in simulations in PZFlex® software were run in Matlab® to visualize the acoustic field and to extract parameter. The ultrasound kerfless transducer was simulated in PZFlex® and the data obtained runs in Matlab®, the results were compared with the results of a transducer with kerf in the same configuration. The simulation results showed that the acoustic field of this kind of transducer has Fraunhofer zone began near the transducer's face. The backing layer with epoxy and Araldite® showed high amplitude of acoustic field. The frequency 30 MHz was choice due to diameter/thickness relations. The excitation function was wavelet, as this present high values response in acoustic field. Kerfless transducer showed acoustic field characteristics the same as the kerf transducers, with the advantage of a simple construction / Doutorado / Engenharia Biomedica / Doutora em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/261168
Date05 October 2013
CreatorsNascimento, Valéria Monteiro do, 1974-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Button, Vera Lúcia da Silveira Nantes, 1959-, Maia, Joaquim Miguel, Costa, Eduardo Tavares, Muhlen, Sérgio Santos, Carneiro, Antônio Adilton
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format206 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.018 seconds