Estudo da liga de aluminio-zinco como filtração alternativa para a radiação X

Orientação: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T14:26:03Z (GMT). No. of bitstreams: 1
Haiter_Claudia_M.pdf: 3563481 bytes, checksum: 0f8631489485e0a3818bb5e6539a19e8 (MD5)
Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi avaliar os efeitos da filtração alternativa da liga alumínio/zinco em aparelhos de raios X odontológicos, em relação ao espectro de energia dos feixes de raios X, a taxa de kerma no ar, o índice de contraste nas radiografias obtidas e qualidade das imagens radiográficas. Este estudo foi realizado comparando o filtro convencional de alumínio com várias espessuras do filtro de liga alumínio/zinco, em diferentes porcentagens do elemento zinco na liga (2%, 3%, 4% e 5%). Foi utilizado um aparelho de raios X odontológico
convencional, operando com 60 kVp e 70 kVp, e filmes radiográficos pertencentes ao grupo D e E de sensibilidade. Foram realizadas radiografias de um "phantom" e de uma escala de densidade de alumínio. O uso dos filtros de liga AI/Zn resultou em um não endurecimento dos feixes. A taxa de kerma no ar diminuiu em até 18,53%, sem alteração no contraste das radiografias. A qualidade das imagens obtidas com os filtros de liga AIZn também tiveram uma boa aceitação pelos examinadores. A análise dos resultados nos levou a concluir que o filtro de liga AIZn 2%, com 1,99 mm de espessura, tensão de 60 kVp, quando usado com filme D, foi o que obteve melhor desempenho, reduzindo a taxa de kerma no ar sem variar o índice de contraste das radiografias, mantendo a qualidade da imagem aceitável para diagnóstico, sem contudo aumentar o tempo de exposição / Abstract: The aim of this research was evaluate the effects of the alternative filtration of the aluminumlzinc alloy in dental X rays machines, in relation to the spectrum of energy , the X ray dose, the contrast alterations and the image quality. This study was accomplished comparing the conventional aluminum filter with several thickness of the aluminumlzinc alloy filter, in different percentages of zinc in the alloy (2%, 3%, 4% and 5%). It was used a conventional X ray machine, operating with 60 kVp and 70 kVp, and D and E speed films, in order to obtain
images of a phantom and of a aluminum step wedge. The use of the filters Al/Zn resulted in a spectra with smaller amount of fótons, however it was not found hardening of the beam. The kerma in the air was decreased in up to 18,53%, without alteration in the contrast of the images. The quality of the images obtained with the filters Al/Zn also had a good acceptance for the examiners. The analysis of the results showed that the filter alloy Al/Zn 2%, with 1,99 mm of thickness, tension of 60 kVp, when used with film D, obtained the best performance, reducing the
kerma in the air without reducing contrast, and the image quality was considered acceptable for diagnosis. This filter also didn't needed an increase in the exposition time that would cause an consequent increase in the load of the tube / Mestrado / Mestre em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288904
Date15 December 2000
CreatorsHaiter, Claudia
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Boscolo, Frab Norberto, 1942-, Chilvarquer, Israel, Almeida, Solange Maria de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format140p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess