• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analise de materiais em suspensão de aguas por espectrometria de fluorescencia de raios X : avaliação de metodo

Santos, Shirley Pereira 26 August 2003 (has links)
Orientador: Jacinta Enzweiler / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-08-03T18:03:15Z (GMT). No. of bitstreams: 1 Santos_ShirleyPereira_M.pdf: 1989104 bytes, checksum: d5f6519b16c26f28fe138007ac8ebf7f (MD5) Previous issue date: 2003 / Resumo: Tipicamente, análises de águas em sistemas naturais são realizadas após a filtração por membrana com diâmetro de poro de 0,45 J..lm. O material particulado em suspensão retido durante a filtração, que na maior parte dos casos é descartado sem ser analisado, é de grande interesse, pois, permite avaliar diversos parâmetros de meios aquáticos. Dentre eles, os mais importantes são a quantidade e a composição de material transportado. Uma característica do material particulado em suspensão é sua grande capacidade de retenção de espécies químicas e, por isto, o destino maior parte dos metais presentes em sistemas aquáticos está associado com o destes sedimentos. Neste trabalho desenvolveu-se um método para analisar diretamente o material particulado depositado nos filtros, utilizando-se a espectrometria de tluorescência de raios X com dispersão de comprimento de onda, e correção de efeitos matriz baseados em parâmetros fundamentais. Uma calibração dedicada foi preparada, empregando como padrões materiais de referência certificados de sedimentos e solos, depositados em filtros. Da mesma forma, avaliou-se a exatidão dos resultados, os quais demonstraram ser possível a determinação quantitativa de elementos maiores e a semi-quantitativa de elementos-traço nos materiais estudados, indicando que o método proposto é adequado quando se deseja monitorar e estudar ambientes aquáticos, pois é simples e rápido. Amostras de material particulado em suspensão de água coletada em dois rios foram analisadas. Os resultados finais dependem da composição global da amostra, isto é, do tipo e concentração dos elementos (p.ex., C, H, N) presentes no material particulado e não dosados na FRX. Se conhecidos, estes componentes podem ser informados durante os cálculos. O método também pode ser adaptado para analisar pequenas quantidades de materiais pulverizados, insolúveis em água / Abstract: Typically, analyses of waters in natural systems are carried out after filtration on membranes with diameter of pore of 0.45 pIIl. The suspended particuJate material retained during the filtration, wbich is discarded without analysis in most cases, is of great interest because it can be used to evaluate important parameters of aquatic media. lhe most important are the quantity and ~on of transported sediments. A characteristic of suspended particu1ate material is its great capacity of retention of chemical species and for tbis reason these sedimeots control the fàte of metais in aquatic systems. In tbis work, a metbod was developed to analyze the suspeoded particu1ate material deposited on fiIters, directly by wavelength X-ray tluorescence spectrometry (WD XRF). Matrix correctioos / Mestrado / Metalogenese / Mestre em Geociências
2

Estudo da liga de aluminio-zinco como filtração alternativa para a radiação X

Haiter, Claudia 15 December 2000 (has links)
Orientação: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T14:26:03Z (GMT). No. of bitstreams: 1 Haiter_Claudia_M.pdf: 3563481 bytes, checksum: 0f8631489485e0a3818bb5e6539a19e8 (MD5) Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi avaliar os efeitos da filtração alternativa da liga alumínio/zinco em aparelhos de raios X odontológicos, em relação ao espectro de energia dos feixes de raios X, a taxa de kerma no ar, o índice de contraste nas radiografias obtidas e qualidade das imagens radiográficas. Este estudo foi realizado comparando o filtro convencional de alumínio com várias espessuras do filtro de liga alumínio/zinco, em diferentes porcentagens do elemento zinco na liga (2%, 3%, 4% e 5%). Foi utilizado um aparelho de raios X odontológico convencional, operando com 60 kVp e 70 kVp, e filmes radiográficos pertencentes ao grupo D e E de sensibilidade. Foram realizadas radiografias de um "phantom" e de uma escala de densidade de alumínio. O uso dos filtros de liga AI/Zn resultou em um não endurecimento dos feixes. A taxa de kerma no ar diminuiu em até 18,53%, sem alteração no contraste das radiografias. A qualidade das imagens obtidas com os filtros de liga AIZn também tiveram uma boa aceitação pelos examinadores. A análise dos resultados nos levou a concluir que o filtro de liga AIZn 2%, com 1,99 mm de espessura, tensão de 60 kVp, quando usado com filme D, foi o que obteve melhor desempenho, reduzindo a taxa de kerma no ar sem variar o índice de contraste das radiografias, mantendo a qualidade da imagem aceitável para diagnóstico, sem contudo aumentar o tempo de exposição / Abstract: The aim of this research was evaluate the effects of the alternative filtration of the aluminumlzinc alloy in dental X rays machines, in relation to the spectrum of energy , the X ray dose, the contrast alterations and the image quality. This study was accomplished comparing the conventional aluminum filter with several thickness of the aluminumlzinc alloy filter, in different percentages of zinc in the alloy (2%, 3%, 4% and 5%). It was used a conventional X ray machine, operating with 60 kVp and 70 kVp, and D and E speed films, in order to obtain images of a phantom and of a aluminum step wedge. The use of the filters Al/Zn resulted in a spectra with smaller amount of fótons, however it was not found hardening of the beam. The kerma in the air was decreased in up to 18,53%, without alteration in the contrast of the images. The quality of the images obtained with the filters Al/Zn also had a good acceptance for the examiners. The analysis of the results showed that the filter alloy Al/Zn 2%, with 1,99 mm of thickness, tension of 60 kVp, when used with film D, obtained the best performance, reducing the kerma in the air without reducing contrast, and the image quality was considered acceptable for diagnosis. This filter also didn't needed an increase in the exposition time that would cause an consequent increase in the load of the tube / Mestrado / Mestre em Radiologia Odontológica
3

Espectrometria de raios-X aliada a quimiometria na determinação de parametros de petroleo / X-ray spectrometry allied to chemometrics in the determization of petroleum parameters

Henriques, Claudete Bernardo 08 May 2008 (has links)
Orientadores: Rubens Maciel Filho, Maria Izabel M. S. Bueno / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-11T19:29:50Z (GMT). No. of bitstreams: 1 Henriques_ClaudeteBernardo_M.pdf: 3645834 bytes, checksum: 16d6c77b7c64c77aaf38edbfb3f50d60 (MD5) Previous issue date: 2008 / Resumo: No mundo inteiro, a demanda por petróleo tem aumentado ao mesmo tempo em que as reservas de petróleos leves têm diminuído drasticamente. Neste cenário, a alternativa de exploração de óleos pesados, principalmente oriundos de águas profundas localizadas em regiões costeiras, tem se intensificado. Esta alternativa altera em muito os procedimentos padrão de refinarias, como também tem exigido uma rápida e confiável forma de caracterização destas amostras, que têm como características principais baixos valores de grau API, alta viscosidade, altos teores de asfaltenos e resinas, assim como a presença de compostos oxigenados, nitrogenados, organometálicos e impurezas oleofóbicas. Para preencher parte desta lacuna, esta dissertação apresenta um novo método analítico, adequado para análises de rotina, baseado na correlação de Espectrometria de Raios-X e alguns dos parâmetros mencionados acima, como determinação do teor de asfaltenos, de metais, de grau API, assim como a classificação dos petróleos em leves e pesados. As correlações são obtidas através de modelamento quimiométrico dos espectros com dados obtidos através de métodos padrão IP 143-1984(89) e/ou ASTM D6560-00 para o teor de asfaltenos, ASTM D 5708-05 e ISO 14597-97(E) para o teor de níquel, vanádio e ferro por ICP (do inglês, inductively coupled plasma) e XRS (do inglês, X-ray Spectrometry), respectivamente. Estes métodos padrão são inadequados para análise de rotina, já que se apresentam, em alguns casos, como laboriosos, demandando tempo, uso exaustivo de reagentes, gerando, portanto, resíduos quase sempre tóxicos. O uso do espalhamento raios X como sinal analítico para a determinação do teor de asfaltenos é fundamental para abrir uma nova perspectiva em se empregar a XRS (do inglês, X-ray Spectrometry) para análise desta propriedade, apresentado resultados que superaram os até então obtidos para correlação com o método de referência IP 143-1984 (89). Os modelos foram obtidos pelas ferramentas PCA (do inglês, Principal Component Analysis) e PLS (do inglês, Partial Least Square Regression), obtendo-se correlações acima de 0,9 entre os valores previstos e medidos pelos métodos padrão. Assim, esta dissertação é pioneira, já que visa incentivar o desenvolvimento de novos trabalhos correlatos / Abstract: In the whole world, the petroleum demand is increasing whereas light oils reserves are deeply decreasing. In this scenery the exploration of off-shore heavy oils in coastal deep waters is urgent. This alternative deeply alters the standard procedures in petroleum refineries and requires fast and reliable sample characterization methods. The samples present as main features low API degrees, high viscosity, high asphaltene and resin contents, the presence of oxygenated, nitronenated and organometallic compouns, as well as oleophobic impurities. To fill a part of this blank, this work shows the development of a new analytical method, nicely applicable to routine, based on the correlation of X-ray Spectrometry (XRS) and some of the parameters mentioned above, as the determination of asphaltene and metal contents, of API degree, as well as the classification of samples as light or heavy petroleums. The correlations are reached through chemometric modelling between the spectra and data obtained by standard methods IP 143-1984(89) and/or ASTM D6560-00 for asphaltene content, ASTM D 5708-05 and ISO 14597-97(E) for nickel, vanadium and iron determinations by ICP (Inductively Coupled Plasma) and XRS (X-ray Spectrometry), respectively. All the standard methods are inadequate for routine analysis, since they are laborious, extremelly reagent- and time-consuming, generating toxic residuals. The use of X-ray scattering as analytical signal to determine asphaltene content is fundamental to open a new perspective in X-ray Spectrometry, showing better performance than reference method (IP 143-1984(89)). The models were obtained by applying chemometric tools, as PCA (Principal Component Analysis) and PLS (Partial Least Square Regression), with correlation coefficients above 0.99 between measured and previewed values. So, this work is pioneer, opening new possibilities for future simultaneous applications in petroleum and co-products characterizations / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química

Page generated in 0.0801 seconds