The temperature dependent electrical characteristics of silicon carbide power transistors – 4H-SiC metal semiconductor field-effect transistors (MESFETs) and 4H-SiC bipolar junction transistors (BJTs) have been investigated through simulation and experimental approaches. Junction temperatures and temperature distributions in devices under large power densities have been estimated. The DC and RF performance of 4H-SiC RF Power MESFETs have been studied through two-dimensional electro-thermal simulations using commercial software MEDICI and ISE. The simulated characteristics of the transistors were compared with the measurement results. Performance degradation of transistors under self-heating and high operating temperatures have been analyzed in terms of gate and drain characteristics, power density, high frequency current gain and power gain. 3D thermal simulations have been performed for single and multi-finger MESFETs and the simulated junction temperatures and temperature profiles were compared with the results from electro-thermal simulations. The reduction in drain current caused by self-heating was found to be more prominent for transistors with more fingers and it imposes a limitation on both the output power and the power density (in W/mm) of multi-fingered large area devices. Thermal issues for design of high power multi-fingered SiC MESFETs were also investigated. A couple of useful ways to reduce the self-heating effects were discussed. Trap-induced performance instabilities of the devices were analyzed by carrying out DC, transient, and pulse measurements at room and elevated temperatures. Electrical characteristics of 4H-SiC BJTs have been measured. A reduction in current gain at elevated temperatures was observed. Based on the collector current-voltage diagram measured at three different ambient temperatures the junction temperature was extracted using the assumption that the current gain only depends on the temperature. Temperature measurements have been carried out for SiC BJTs. Thermal images of a device under operation were recorded using an infrared camera. 3D thermal simulations were conducted using FEMLAB. Both the simulations and the measurement showed a significant temperature increase in the vicinity of the device when operated at high power densities, thus causing the decrease of the DC current gain. The junction temperatures obtained from the thermal imaging, simulation and extraction agree well.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:kth-86 |
Date | January 2004 |
Creators | Liu, Wei |
Publisher | KTH, Mikroelektronik och informationsteknik, IMIT, Kista : Mikroelektronik och informationsteknik |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Doctoral thesis, comprehensive summary, info:eu-repo/semantics/doctoralThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Relation | Trita-EKT, 1650-8599 ; 2004:7 |
Page generated in 0.0022 seconds