Desempenho dos métodos de instalação de transdutores piezelétricos em sistemas de monitoramento de integridade estrutural baseados na impedância eletromecânica / Performance of installation methods in piezoelectrics transducers in structural integrity monitoring systems based on electromechanical impedance

Submitted by RICARDO ZANNI MENDES DA SILVEIRA null (ricazanni@gmail.com) on 2017-06-07T16:11:41Z
No. of bitstreams: 1
Dissertação_Mestrado_Eng_Eletrica_Ricardo_Zanni_2017.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-07T16:26:32Z (GMT) No. of bitstreams: 1
silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Made available in DSpace on 2017-06-07T16:26:32Z (GMT). No. of bitstreams: 1
silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5)
Previous issue date: 2017-05-26 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Transdutores piezelétricos são amplamente utilizados em muitos métodos não destrutivos para a detecção de danos estruturais em aplicações de monitoramento de integridade estrutural ou SHM (Structural Health Monitoring). Dentre os vários métodos não destrutivos, a técnica da impedância eletromecânica (E/M) é conhecida por utilizar cerâmicas piezelétricas pequenas e finas que desempenham simultaneamente as funções de atuador e sensor. O método convencional de instalação dessas cerâmicas piezelétricas na estrutura é utilizando um adesivo de alta rigidez como cola a base de epóxi ou cianoacrilato. No entanto, alguns estudos propõem métodos alternativos de instalação do transdutor, visando a sua reutilização ou que permitam o monitoramento em condições adversas sob as quais a instalação direta do sensor não seria possível. Assim, esta dissertação de mestrado apresenta uma análise experimental comparativa entre os principais métodos de acoplamento entre o transdutor piezelétrico e a estrutura monitorada em sistemas de SHM baseados na técnica da impedância eletromecânica (E/M). Os acoplamentos dos transdutores piezelétricos foram realizados pelos métodos da instalação direta, também conhecida como instalação convencional, por acoplamento magnético e lâminas de alumínio. O transdutor utilizado para os métodos de acoplamento foi o diafragma piezelétrico, comumente conhecido como buzzer. Testes com os três métodos de instalação foram realizados em estruturas de alumínio e o dano estrutural foi induzido por meio de adição de massa metálica (porca de aço), fixada diretamente na estrutura com cola a base de cianoacrilato. A análise comparativa entre os métodos de instalação foi realizada utilizando índices de danos obtidos das assinaturas de impedância elétrica dos diafragmas piezelétricos, além da função de resposta em frequência (FRF) e da densidade espectral de potência obtida pelo método da quebra do grafite. Os resultados experimentais apontam características importantes para os métodos de instalação, os quais têm influência significativa sobre a resposta em frequência e sensibilidade para a detecção de danos estruturais. / Piezoelectric transducers are widely used in many non-destructive methods for detecting structural damage in Structural Health Monitoring (SHM) applications. Among the various techniques for detecting structural damage, the electromechanical impedance (EMI) technique is known to use fine and small piezoelectric ceramics that simultaneously perform the actuator and sensor functions. The conventional method of installing these piezoelectric ceramics in the structure is by using a high stiffness adhesive such as epoxy or cyanoacrylate based glue. However, some studies propose alternative methods of installing the transducer for reuse or to allow monitoring under adverse conditions under which direct sensor installation would not be possible. Thus, this master's thesis presents a comparative experimental analysis between the main coupling methods between the piezoelectric transducer and the monitored structure in SHM systems based on the electromechanical impedance technique. The piezoelectric transducer couplings were made by direct installation methods, also known as conventional installation, by magnetic coupling and aluminum foils. The transducer used for the coupling methods was the piezoelectric diaphragm, commonly known as buzzer. Tests with these methods were carried out on aluminum structures and the structural damage was induced using metallic masses (steel nuts), fixed directly to the structure with cyanoacrylate-based glue. The comparison of the results analysis between the coupling methods was performed using the indices of damages obtained from electrical impedance signatures of the piezoelectric diaphragm, the frequency response function (FRF) and the power spectral density (PSD) obtained by pencil lead break (PLB) test. The experimental results indicate important characteristics for each installation method and that the mounting method has a significant influence on the frequency response and sensitivity for the detection of structural damage. / FAPESP: 2015/02500-6

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/150859
Date26 May 2017
CreatorsSilveira, Ricardo Zanni Mendes da [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Baptista, Fabricio Guimarães [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation600

Page generated in 0.0024 seconds