Return to search

Analise de sensibilidade de parametros eletricos de linhas de transmissão no dominio da frequencia / Sensitivity analysis of electrical transmission line parameters in frequency domain

Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e Computação / Made available in DSpace on 2018-08-08T12:51:45Z (GMT). No. of bitstreams: 1
Pinheiro_MichelGonA§alves_M.pdf: 1094075 bytes, checksum: 1c9863b695ee82d8312c89c87f94085b (MD5)
Previous issue date: 2005 / Resumo: Este trabalho apresenta uma extensa análise de sensibilidade dos parâmetros elétricos longitudinais e transversais de uma linha de transmissão trifásica em função da freqüência. Uma linha real de 440 kV foi utilizada como base para as análises. Considerando determinadas hipóteses simplificadoras, foram calculados os parâmetros elétricos da linha: resistência, indutância e capacitância no domínio da freqüência. Esses parâmetros foram apresentados em termos das parcelas das matrizes primitivas, das matrizes reduzidas e componentes modais. Na análise de sensibilidade variaram-se as seguintes características da linha: diâmetros dos cabos pára-raios, diâmetros dos condutores fase, altura dos condutores, distância horizontal entre as fases, espaçamento vertical dos sub-condutores dos feixes das fases externas. Para cada variação observou-se o comportamento dos parâmetros elétricos em função da freqüência, em termos das parcelas das matrizes primitivas e em termos dos modos. Também foi observado o fator de aterramento e foram estimados os aumentos de potência natural em função das variações realizadas. As linhas com elevada potência natural (LPNE) foram avaliadas no âmbito da análise efetivada / Abstract: In this work a large sensitivity analysis of longitudinal and transversal electrical parameters of a three-phase transmission line in frequency domain was performed. An actual 440 kV transmission line was used as reference in the analysis. Considering some simplified hypothesis, electrical parameters, as resistance, inductance and capacitance, were evaluated in frequency domain. Those parameters were presented in terms of parcels of primitive matrices and reduced matrices in phase modal domain. An extensive sensitivity analysis was performed and the following line caracteristics were varied: ground wires diameter, phase conductors diameter, height of conductors, horizontal distance among phases and vertical spacing within external phases bending. For each line caracteristic, the performance of electrical parameters in frequency domain, in terms of primitive and modal matrices was observed. Also, it was observed the ground factor and it was estimated the increases on natural power. Using of High Natural Power Lines was studied and related to variations of line geometry / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259608
Date17 November 2005
CreatorsPinheiro, Michel Gonçalves
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tavares, Maria Cristina Dias, 1962-, Portela, Carlos Manuel de Jesus Cruz de Medeiros, Garcia, Ariovaldo
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format123p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0144 seconds