This project deals with voltage source converters with energy storage capability. The main objective is to study the possible benefits of energy storage to a power system with a VSC as the interface between them. First of all, a converter control system is proposed for a two level VSC. In the conventional converter control, the control system usually takes the voltage measured at the point where the converter is connected and calculates the reference voltage for the converter; with a modulation system the converter then produces the required 'average voltage'. In this project, a novel flux modulation scheme, combined with the deadbeat current control strategy, is proposed. The current controller is capable of controlling both positive and negative sequence current components. With flux modulation, the control system measures the bus flux and commands the converter to generate the required flux. Based on the proposed control strategies, several application studies have been carried out. The first application study investigates the effect of energy storage on the power quality at the point of common coupling when a system is subject to load disturbances. The voltage at PCC in a weak network is very sensitive to load changes. A sudden change in active load will cause both a phase jump and a magnitude fluctuation in the bus voltage, whereas reactive load changes mainly affect the voltage magnitude. With the addition of energy storage to a StatCom, it is possible to compensate for the active power change as well as providing reactive power support. In this thesis, some effective active power compensation schemes are proposed. Simulations and experiments have been performed to verify the compensation schemes. The results show that a StatCom with energy storage can significantly reduce phase jumps and magnitude deviations of the bus voltage. pact of the energy storage on the performance of weak systems under fault conditions has been investigated. The investigation was done by studying an example system. The system model was established based on a real system, in which some induction motors driving pumps along a pipeline are fed from a radial transmission line. Studies show that for a weak system with induction motor loads, a StatCom with certain energy storage capacity will effectively improve the system recovery after faults. Although this incurs extra cost for the increasing dc voltage rating and size of the dc side capacitor, the overall rating of the converter can be reduced by utilization of the proposed active power compensation scheme. The last case study investigates the possible use of a StatCom with energy storage to improve the power quality at the point of common coupling where a cyclic load is connected. Studies show that by providing both fast reactive and fast active power support to the network, not only the voltage magnitude can be well controlled, but also the voltage phase jump can be reduced significantly. / QC 20101124
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:kth-4191 |
Date | January 2006 |
Creators | Xie, Hailian |
Publisher | KTH, Skolan för elektro- och systemteknik (EES), Stockholm : KTH |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Licentiate thesis, monograph, info:eu-repo/semantics/masterThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Relation | Trita-EE, 1653-5146 ; 2006:057 |
Page generated in 0.0028 seconds