Return to search

Influência do formato do rebordo alveolar na distribuição interna das tensões em prótese parcial removível dento-implantossuportada

Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-12-06Bitstream added on 2014-06-13T18:07:43Z : No. of bitstreams: 1
martinjunior_m_me_araca.pdf: 1987212 bytes, checksum: 7b293d4845e041e9d49b2c3d5d18fcce (MD5) / Universidade Estadual Paulista (UNESP) / Os dados sobre a influência da forma do rebordo alveolar na distribuição interna das tensões na associação da prótese parcial removível de extremidade livre (PPREL) com os implantes osseointegrados são inconclusivos. Assim, o objetivo deste estudo foi avaliar através do método dos elementos finitos (MEF) bi-dimensional, a influência do formato do rebordo alveolar na distribuição interna das tensões. Para isso, foram confeccionados 12 (doze) modelos no programa AutoCAD 2005 (Autodesk Inc, USA), sendo: Modelo A (MA) - hemiarcada com a representação do dente natural 33 e o rebordo edentado para distal; Modelo B (MB) - semelhante ao MA com uma PPREL convencional substituindo os dentes ausentes 34, 35, 36 e 37; Modelo C (MC) - semelhante ao MB, porém com um implante do Sistema Bränemark (3,75 x 10,0 mm) posicionado na região retromolar, sob a base da prótese, conferindo apenas suporte; Modelos A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 e C4 foram baseados nos respectivos modelos: A, B e C, com a identificação numérica seguindo a forma do rebordo alveolar no plano sagital, como descrito: descendente distal (1), côncavo (2), plano (3) e ascendente distal (4). Os modelos foram exportados para o programa de elementos finitos ANSYS 8.0 (Swanson Analysis Systems, Houston, Pa) para a análise numérica. O carregamento foi realizado com forças verticais de 50 N. Os resultados mostraram que máxima tendência ao deslocamento para os rebordos analisados ocorreu de forma semelhante entre os modelos B e C, sendo: descendente distal (B1 - 0,2484 mm e C1- 0,2513 mm), plano (B3 - 0,2415 mm e C3 0,2452 mm), côncavo (B2 - 0,2377 mm e C2 0,2392 mm) e ascendente distal (B4 - 0,2255 mm e C4 - 0,2293 mm); a máxima concentração de tensão nos modelos B apresentou a seguinte ordem: descendente distal (288,77 MPa), côncavo (199,99 Mpa), plano (197,11 MPa) e ascendente distal (185,22 MPa)... . / The data about the influence of the alveolar ridge shape in the stress distribution during the association of a free-end saddle removable partial denture (FERPD) with an osseointegrated implant are inconclusive. Thus, the objective of this study was to evaluate, by bidimensional the finite element analysis (FEA), the influence of the alveolar ridge shape in the stress distribution. For this, 12 (twelve) models were created in the program AutoCAD 2005 (Autodesk Inc, USA), representing: model A (MA) - hemiarch containg only the natural tooth 33 and edentulous space for distal; model B (MB) - similar to MA with a conventional FERPD replaying the absent teeth 34, 35, 36 and 37; model C (MC) - similar to MB, however with an implant of the Sistema Bränemark (3,75 x 10,0 mm) positioned in posterior area, in order to support FERPD base; Models A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 and C4 were based on the respective models: A, B and C, with the numeric identification following the shape in the sagital plane, as described: distal descending (1), concave (2), plan (3) and distal ascendancy (4). The models were exported for the FEA hardware (ANSYS 8.0 Swanson Analysis Systems, Houston, PA) for numeric analysis. The loading were performance with vertical forces of 50 N. The results showed maximum displacement tendency (mm) were between models B and C: distal descending (B1 - 0.2484 mm and C1 - 0.2513 mm), plan (B3 - 0.2415 mm and C3 0.2452 mm), concave (B2 - 0.2377 mm and C2 0.2392 mm) and distal ascendancy (B4 - 0.2255 mm and C4 - 0.2293 mm); the maximum stress concentration for models B were distal descending (288,77 MPa), concave (199,99 MPa), plan (197,11 MPa) and distal ascendancy (185,22 MPa); the model C present an inversion between plan and distal ascending shape: C1 with 395,93 MPa, C2 with 341,49 MPa, C4 with 266,02 MPa and C3 with 219,58 MP... (Complete abstract, click electronic address below).

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/97385
Date06 December 2005
CreatorsMartin Júnior, Manoel [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Rocha, Eduardo Passos [UNESP], Pereira, João Antônio [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format197 f. : il. + 1 CD-ROM
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0022 seconds