• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Martins, Renato 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
2

Avaliação da citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de TI- 6AL-4V após imersão em saliva artificial fluoretada por 30, 90 ou 180 dias

Lemes, Sandra Stival dos Santos 25 February 2008 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:32:51Z No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:33:13Z (GMT) No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-02-12T19:33:13Z (GMT). No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2008-02-25 / The alloys used in the orthodontic therapy are subject to the corrosion process in the oral environment. Orthodontic mini-implants Ti-6Al-4V are an excellent source for intraoral anchorage; however, their corrosion resistance in the presence of fluoride is currently unknown. The purpose of this in vitro study was to evaluate the cytotoxic effects of the corrosion extracts of mini-implants Ti-6Al-4V from three different manufacturers when exposed to 200 g/L of sodium fluoride containing artificial saliva for 30, 90 or 180 days. The cytotoxic effects of their corrosion products on L929 cell culture was evaluated by MTT (3- [4,5-dimethylthiazol-2-yl]2,5-diphenyltetrazolium bromide) assay, for cell metabolism and proliferation. The extracts were not cytotoxic and the cytotoxicity assay demonstrated a similar behavior for the samples immersed in artificial saliva in the three evaluated periods. The qualitative analysis, through SEM did not show characteristics of corrosion. The results indicated that the mini-implants tested presented a high corrosion resistance and biocompatibility. / As ligas metálicas utilizadas na terapia ortodôntica estão sujeitas ao processo de corrosão na cavidade bucal. Mini-implantes de Ti-6Al-4V utilizados em ortodontia tornou-se um ótimo recurso de ancoragem intrabucal, contudo, sua resistência à corrosão na presença de flúor é pouco conhecida. O objetivo deste trabalho in vitro foi avaliar a citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de Ti-6Al-4V de três diferentes marcas comerciais, quando expostos em saliva artificial fluoretada contendo 200 µg/L de fluoreto de sódio, por 30, 90 ou 180 dias. A citotoxicidade dos extratos foi avaliada, em cultura de células L929, por meio da análise do ensaio do MTT (3-{4,5-dimetiltiazol-2il} -2,5-difenil brometo de tetrazólio). Os extratos não foram citotóxicos e o ensaio de citotoxicidade revelou não haver diferenças entre as amostras, demonstrando um comportamento semelhante para os extratos provenientes dos mini-implantes imersos em saliva nos três períodos avaliados. A análise qualitativa, por meio do MEV não revelou áreas com características de corrosão propriamente dita. Os resultados demonstraram que os mini-implantes testados apresentam alta resistência à corrosão e sugerem que são biocompatíveis.
3

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Renato Martins 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
4

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos /

Tabata, Lucas Fernando. January 2005 (has links)
Resumo: No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / Abstract: on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antônio Capello Sousa / Banca: Eduardo Passos Rocha / Banca: Ricardo Faria Ribeiro / Banca: Wirley Gonçalves Assunção / Mestre
5

Sobrevida e perda marginal óssea de implantes de diâmetro estreito de liga titânio-zircônia e titânio puro / Survival rate of titanium-zirconium narrow diameter dental implants and commercially pure titanium narrow diameter dental implants

Iegami, Carolina Mayumi 15 August 2018 (has links)
Apesar da existência de diversos estudos que validem o uso de implantes de diâmetro estreito, a maioria é baseada em ligas de titânio puro. Há pouca evidência clínica em relação ao sucesso do implantes de diâmetro estreito de titânio-zircônia (TiZr NDIs), no que diz respeito à taxa de sobrevida (SR) e perda óssea marginal (MLB). O objetivo desta revisão sistemática foi analisar sistematicamente SR, assim como MBL de TiZr NDIs quando comparados a implantes de diâmetro estreito de titânio comercialmente puro (cpTi NDIs). A busca foi conduzida nas bases Medline/Pubmed, Cochrane, Scopus e Embase (do ano 2000 a novembro de 2016). Foram incluídos estudos clínicos do tipo coorte e randomizados. Dos 3453 artigos inicialmente identificados, foram incluídos seis estudos clínicos. Não houve diferença estatisticamente significante em taxa de sobrevida quando comparados os grupos TiZr NDIs e cpTi NDIs, em um ano de acompanhamento (p=0,5), além disso, também não houve diferença na comparação entre região de implantação (anterior ou posterior) no grupo TiZr NDIs. Não houve diferença entre os grupos anterior e posterior em relação à taxa de sobrevida em um ano: -0,01 (95% CI, -0,05 a 0,03) e perda óssea marginal: -0,01 mm (95% CI: -0,14 a 0,12). Pode-se concluir que TiZr NDIs apresentam taxas de sucesso e reabsorção óssea peri-implantar similares às de cpTi NDis. / Despite the existence of several studies validating the use of narrow diameter implants, most of them are based on pure Ti alloys. There is few clinical evidence of the success of TiZr narrow diameter implants (TiZr NDIs) regarding survival rate and marginal bone loss. The aim of this review was to systematically assess survival rate, as well as marginal bone loss of TiZr NDIs compared to commercially pure titanium narrow diameter implants (cpTi NDIs). Material and Methods: The search was conducted in Medline/PubMed, Cochrane, Scopus and Embase databases (year 2000 to November 2016). Cohort studies and randomized trials were included. Results: Six clinical studies from the 3453 articles initially identified met the inclusion criteria. There were no statistically significant differences in survival rate when TiZr NDIs and cpTi NDIs were compared in the 1-year follow up (p=0.5), or when comparing TiZr NDIs placed in posterior and anterior regions. There was no difference between groups regarding 1-year SR: -0.01 (95% CI, -0.05 to 0.03) and MLB: -0.01 mm (95% CI: -0.14 to 0.12). Conclusion: It can be concluded that TiZr NDIs present similar success rates and peri-implant bone resorption to cpTi NDIs.
6

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos

Tabata, Lucas Fernando [UNESP] 05 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-05Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 tabata_lf_me_araca.pdf: 8309973 bytes, checksum: 5d726f976a2382ac0dc6e3d5eff78d89 (MD5) / Universidade Estadual Paulista (UNESP) / No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below)
7

Influência do formato do rebordo alveolar na distribuição interna das tensões em prótese parcial removível dento-implantossuportada

Martin Júnior, Manoel [UNESP] 06 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-06Bitstream added on 2014-06-13T18:07:43Z : No. of bitstreams: 1 martinjunior_m_me_araca.pdf: 1987212 bytes, checksum: 7b293d4845e041e9d49b2c3d5d18fcce (MD5) / Universidade Estadual Paulista (UNESP) / Os dados sobre a influência da forma do rebordo alveolar na distribuição interna das tensões na associação da prótese parcial removível de extremidade livre (PPREL) com os implantes osseointegrados são inconclusivos. Assim, o objetivo deste estudo foi avaliar através do método dos elementos finitos (MEF) bi-dimensional, a influência do formato do rebordo alveolar na distribuição interna das tensões. Para isso, foram confeccionados 12 (doze) modelos no programa AutoCAD 2005 (Autodesk Inc, USA), sendo: Modelo A (MA) - hemiarcada com a representação do dente natural 33 e o rebordo edentado para distal; Modelo B (MB) - semelhante ao MA com uma PPREL convencional substituindo os dentes ausentes 34, 35, 36 e 37; Modelo C (MC) - semelhante ao MB, porém com um implante do Sistema Bränemark (3,75 x 10,0 mm) posicionado na região retromolar, sob a base da prótese, conferindo apenas suporte; Modelos A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 e C4 foram baseados nos respectivos modelos: A, B e C, com a identificação numérica seguindo a forma do rebordo alveolar no plano sagital, como descrito: descendente distal (1), côncavo (2), plano (3) e ascendente distal (4). Os modelos foram exportados para o programa de elementos finitos ANSYS 8.0 (Swanson Analysis Systems, Houston, Pa) para a análise numérica. O carregamento foi realizado com forças verticais de 50 N. Os resultados mostraram que máxima tendência ao deslocamento para os rebordos analisados ocorreu de forma semelhante entre os modelos B e C, sendo: descendente distal (B1 - 0,2484 mm e C1- 0,2513 mm), plano (B3 - 0,2415 mm e C3 0,2452 mm), côncavo (B2 - 0,2377 mm e C2 0,2392 mm) e ascendente distal (B4 - 0,2255 mm e C4 - 0,2293 mm); a máxima concentração de tensão nos modelos B apresentou a seguinte ordem: descendente distal (288,77 MPa), côncavo (199,99 Mpa), plano (197,11 MPa) e ascendente distal (185,22 MPa)... . / The data about the influence of the alveolar ridge shape in the stress distribution during the association of a free-end saddle removable partial denture (FERPD) with an osseointegrated implant are inconclusive. Thus, the objective of this study was to evaluate, by bidimensional the finite element analysis (FEA), the influence of the alveolar ridge shape in the stress distribution. For this, 12 (twelve) models were created in the program AutoCAD 2005 (Autodesk Inc, USA), representing: model A (MA) - hemiarch containg only the natural tooth 33 and edentulous space for distal; model B (MB) - similar to MA with a conventional FERPD replaying the absent teeth 34, 35, 36 and 37; model C (MC) - similar to MB, however with an implant of the Sistema Bränemark (3,75 x 10,0 mm) positioned in posterior area, in order to support FERPD base; Models A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 and C4 were based on the respective models: A, B and C, with the numeric identification following the shape in the sagital plane, as described: distal descending (1), concave (2), plan (3) and distal ascendancy (4). The models were exported for the FEA hardware (ANSYS 8.0 Swanson Analysis Systems, Houston, PA) for numeric analysis. The loading were performance with vertical forces of 50 N. The results showed maximum displacement tendency (mm) were between models B and C: distal descending (B1 - 0.2484 mm and C1 - 0.2513 mm), plan (B3 - 0.2415 mm and C3 0.2452 mm), concave (B2 - 0.2377 mm and C2 0.2392 mm) and distal ascendancy (B4 - 0.2255 mm and C4 - 0.2293 mm); the maximum stress concentration for models B were distal descending (288,77 MPa), concave (199,99 MPa), plan (197,11 MPa) and distal ascendancy (185,22 MPa); the model C present an inversion between plan and distal ascending shape: C1 with 395,93 MPa, C2 with 341,49 MPa, C4 with 266,02 MPa and C3 with 219,58 MP... (Complete abstract, click electronic address below).
8

Influência do formato do rebordo alveolar na distribuição interna das tensões em prótese parcial removível dento-implantossuportada /

Martin Júnior, Manoel. January 2005 (has links)
Resumo: Os dados sobre a influência da forma do rebordo alveolar na distribuição interna das tensões na associação da prótese parcial removível de extremidade livre (PPREL) com os implantes osseointegrados são inconclusivos. Assim, o objetivo deste estudo foi avaliar através do método dos elementos finitos (MEF) bi-dimensional, a influência do formato do rebordo alveolar na distribuição interna das tensões. Para isso, foram confeccionados 12 (doze) modelos no programa AutoCAD 2005 (Autodesk Inc, USA), sendo: Modelo A (MA) - hemiarcada com a representação do dente natural 33 e o rebordo edentado para distal; Modelo B (MB) - semelhante ao MA com uma PPREL convencional substituindo os dentes ausentes 34, 35, 36 e 37; Modelo C (MC) - semelhante ao MB, porém com um implante do Sistema Bränemark (3,75 x 10,0 mm) posicionado na região retromolar, sob a base da prótese, conferindo apenas suporte; Modelos A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 e C4 foram baseados nos respectivos modelos: A, B e C, com a identificação numérica seguindo a forma do rebordo alveolar no plano sagital, como descrito: descendente distal (1), côncavo (2), plano (3) e ascendente distal (4). Os modelos foram exportados para o programa de elementos finitos ANSYS 8.0 (Swanson Analysis Systems, Houston, Pa) para a análise numérica. O carregamento foi realizado com forças verticais de 50 N. Os resultados mostraram que máxima tendência ao deslocamento para os rebordos analisados ocorreu de forma semelhante entre os modelos B e C, sendo: descendente distal (B1 - 0,2484 mm e C1- 0,2513 mm), plano (B3 - 0,2415 mm e C3 0,2452 mm), côncavo (B2 - 0,2377 mm e C2 0,2392 mm) e ascendente distal (B4 - 0,2255 mm e C4 - 0,2293 mm); a máxima concentração de tensão nos modelos B apresentou a seguinte ordem: descendente distal (288,77 MPa), côncavo (199,99 Mpa), plano (197,11 MPa) e ascendente distal (185,22 MPa)... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The data about the influence of the alveolar ridge shape in the stress distribution during the association of a free-end saddle removable partial denture (FERPD) with an osseointegrated implant are inconclusive. Thus, the objective of this study was to evaluate, by bidimensional the finite element analysis (FEA), the influence of the alveolar ridge shape in the stress distribution. For this, 12 (twelve) models were created in the program AutoCAD 2005 (Autodesk Inc, USA), representing: model A (MA) - hemiarch containg only the natural tooth 33 and edentulous space for distal; model B (MB) - similar to MA with a conventional FERPD replaying the absent teeth 34, 35, 36 and 37; model C (MC) - similar to MB, however with an implant of the Sistema Bränemark (3,75 x 10,0 mm) positioned in posterior area, in order to support FERPD base; Models A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 and C4 were based on the respective models: A, B and C, with the numeric identification following the shape in the sagital plane, as described: distal descending (1), concave (2), plan (3) and distal ascendancy (4). The models were exported for the FEA hardware (ANSYS 8.0 Swanson Analysis Systems, Houston, PA) for numeric analysis. The loading were performance with vertical forces of 50 N. The results showed maximum displacement tendency (mm) were between models B and C: distal descending (B1 - 0.2484 mm and C1 - 0.2513 mm), plan (B3 - 0.2415 mm and C3 0.2452 mm), concave (B2 - 0.2377 mm and C2 0.2392 mm) and distal ascendancy (B4 - 0.2255 mm and C4 - 0.2293 mm); the maximum stress concentration for models B were distal descending (288,77 MPa), concave (199,99 MPa), plan (197,11 MPa) and distal ascendancy (185,22 MPa); the model C present an inversion between plan and distal ascending shape: C1 with 395,93 MPa, C2 with 341,49 MPa, C4 with 266,02 MPa and C3 with 219,58 MP... (Complete abstract, click electronic address below). / Orientador: Eduardo Passos Rocha / Coorientador: João Antônio Pereira / Banca: Eduardo Piza Pellizzer / Banca: Renata Cunha Matheus Rodrigues Garcia / Mestre

Page generated in 0.1675 seconds