• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 64
  • 64
  • 64
  • 31
  • 25
  • 21
  • 18
  • 18
  • 18
  • 16
  • 15
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da frequência de ressonância de implantes zigomáticos submetidos a função imediata/precoce

Magalhães Junior, Edival Barreto de January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-15T22:54:23Z (GMT). No. of bitstreams: 1 228112.pdf: 1275787 bytes, checksum: 79e019045ca71eb1c0e747afd40fbfdb (MD5) / O objetivo do estudo foi analisar a evolução da freqüência de ressonância de implantes zigomáticos submetidos a função imediata/precoce (teste) num período de 06 meses, em pacientes com maxila severamente absorvida e, compará-los com a estabilidade dos implantes zigomáticos que tiveram função tardia (controle), e ainda, compará-los com implantes convencionais instalados na região anterior da maxila. Foram avaliados 09 pacientes e mensurados um total de 50 implantes, sendo 18 zigomáticos e 32 convencionais. Os registros foram realizados no momento da instalação do implante (0 dia), em 90 dias e 180 dias para o grupo teste, e, 0 e 180 dias para o controle. No grupo teste, os valores médios da análise da freqüência de ressonância dos implantes zigomáticos na instalação foi de 61,3 ± 18,91 ISQ (quoeficiente de estabilidade do implante), 90 dias após foi de 62,56 ± 9,38 ISQ e em 180 dias, a média foi de 69,44 ± 6,12 ISQ. Não houve diferença estatística comparando 0 e 90, e 0 e 180, porém houve diferença estatisticamente significante para 90 a 180 dias. Foram perdidos 01 implante zigomático e 3 convencionais. No grupo controle, a média ISQ foi de 59,88 no dia da instalação e 61,25 180 dias após. Os valores de freqüência de ressonância dos implantes zigomáticos submetidos a carga imediata/precoce apresentaram uma elevação contínua durante todo o período estudado, e registraram valores médios superiores aos tardios, tanto na instalação quanto 180 dias após. Na comparação entre os tipos de implantes localizados na região posterior (zigomático) e anterior (convencional) da maxila, não houve diferença estatisticamente significante. O estudo apresentou uma taxa de sobrevivência para os implantes zigomáticos teste e controle após 180 dias, de 90% e 100%, respectivamente. The purpose of this clinical study was to evaluate during 06 months, in patients with severe resorbed maxilla, the stability of immediate/early loading zygomatic implants (test) by means of resonance frequence analysis (RFA), compare the stability against delayed loaded zygomatic implants (control) and conventional implants in the anterior maxilla. RFA was used for direct measurement of implant stability of 18 zygomatic and 32 conventional implants in 09 patients. Each implant was tested for primary stability at the time of implant placement, after 90 days and 180 days following surgery. Control group was only assessed at placemet and 180 days. In the test group, the mean values of RFA was 61,3 ± 18,91, 62,56 ± 9,38 and 69,2 ± 6,12 implant stability quotient(ISQ), respectively at the placement, at 90 days, and 180 days. there was no statistically significant difference when was compared 0 to 90 , and 0 to 180, however, from 90 to 180 there was difference. One zygomatic implant and 03 conventional implants failed. In the control group, the mean ISQ values were 59,88 at placement and 61, 25 at 180 days. Resonance frequency analysis method showed a continuous increase of zygomatic immediate/early loading ISQ values during the study and the test group mean ISQ values were higher than the control group both at placement and 180 days after. When comparing implant position (length), i.e., zygomatic against conventional implants, there was no difference in the resonance frequency analysis. The clinical zygomatic implant survival rate during this study for the test and control group was 90% and 100%.
2

Distribuição das tensões nos implantes osseointegrados em função da largura da mesa oclusal

Garanhani, Roberto Ramos January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T17:50:06Z (GMT). No. of bitstreams: 0 / A manutenção dos implantes osseointegrados e suas reabilitações protéticas é uma preocupação constante para a longevidade deste tipo de tratamento. Através deste estudo, revisou-se como as forças atuam sobre uma coroa protética unitária implanto-suportada, sua distribuição através do implante ao osso adjacente, diferenças em relação ao dente natural e os efeitos da diminuição da largura oclusal no controle das tensões na interface osso-implante. A literatura sugere que esta alteração no desenho oclusal diminui as tensões recebidas pelo implante e tecido ósseo adjacente.
3

Estudo retrospectivo multicentro com enxerto ósseo alógeno fresco congelado na reconstrução dos maxilares com a finalidade de implantes dentais

Navarro Júnior, Wilson January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T06:42:01Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:22:05Z : No. of bitstreams: 1 188374.pdf: 2294828 bytes, checksum: d57f2984230f3e15db8ce5e3fde983e2 (MD5) / Com o objetivo de avaliar os resultados de enxertos com osso alógeno fresco congelado do BTME do Hospital de Clínicas da UFPR, na reabilitação dos maxilares com implantes osseointegrados, foi feito um levantamento clínico retrospectivo multicêntro em 99 procedimentos de enxerto no seio maxilar e enxertos ósseos aposicionais, com 267 implantes colocados nos últimos 5 anos. Com a participação de 17 cirurgiões dentistas representantes de 6 centros de ensino de pós-graduação em lato sensu de Curitiba Paraná. Os resultados evidenciaram que o índice de sucesso alcançado com os enxertos foi de 90,9%. Com um percentual de sucesso dos implantes de 93,6%.
4

Análise da rugosidade de superfície obtida pela usinagem de implantes

Togashi, Adriane Yaeko January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Curso de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-18T12:46:06Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T21:05:53Z : No. of bitstreams: 1 179586.pdf: 4365974 bytes, checksum: 1d284379b84aabf1ab5fa4654db99d59 (MD5) / Com o propósito de produzir rugosidade de superfície em implantes odontológicos utilizou-se usinagem através de torneamento cilíndrico. Alterou-se um dos parâmetros de corte, o avanço da ferramenta (f), obtendo, desta forma, quatro grupos: grupo 1 - implante com f=0.05mm; grupo 2 - implante com f=0.1mm; grupo 3 - implante com f=0.13mm e grupo 4 - implante com f=0.15mm. A medição da rugosidade produzida pelo torneamento do implante foi obtida utilizando rugosímetro de contato mecânico. Alterações no avanço da ferramenta modificaram a rugosidade de superfície significantemente em todos os grupos (p < 0,0001). Os valores médios Ra (parâmetro de rugosidade) foram: grupo 1 - 0.588mm (s=0.210); grupo 2 - 1.400mm (s=0.131); grupo 3 - 2.288mm (s=0.008) e grupo 4 - 3.263mm (s=0.141). Acredita-se hoje, baseado na literatura que a rugosidade adequada encontra-se em torno de 1 e 2mm, valores estes obtidos nos grupos 2 e 3 deste estudo.
5

Avaliação volumétrica por meio da tomografia computadorizada de feixe cônico, dos leitos ósseos potencialmente doadores na região de ramo e mento /

Matai, Caio Vinícius Bardi. January 2012 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Francisco Haiter Neto / Banca: Pedro Tortamano Neto / Banca: Samira Esteves Afonso Camargo / Banca: Rafaela Rangel Rosa / Resumo: As tomografias computadorizadas (TCs) tridimensionais (3D) solucionaram em grande parte as inconveniências da sobreposição de estruturas anatômicas comuns aos exames radiográficos convencionais (2D). O propósito neste trabalho foi avaliar por meio da Tomografia computadorizada de feixe cônico (TCFC) qual região oferece maior volume ósseo, se a região de mento ou a região de ramo da mandíbula. Foram selecionados 100 exames de TCFC, de indivíduos com idade de 18 a 89 anos do sexo masculino (50) e do feminino (50) com necessidade de realizar cirurgia para enxertia óssea autógena. Os exames foram avaliados por dois radiologistas treinados, para quantificar o volume ósseo das regiões potencialmente doadoras, que foram avaliadas por diferentes orientações para delimitação do volume potencial do leito doador, utilizando um software para avaliação. Sendo posteriormente avaliados pela análise estatística t de Student, teste de Tukey, correlacionando as diferenças estatísticamente significantes (p < 0,05) entre a avaliação das região mensuradas, por métodos diferentes. Verificou-se o maior potencial doador encontrado na região mentual, chegando a atingir o volume médio de 1,59cm3 contra 1,07cm3 a região de ramo. Concluímos que a região mentual, entre os dentes caninos inferiores, proporciona maior volume ósseo e assim como na revisão da literatura, encontramos maior volume ósseo para a região mentual quando comparada as outras regiões doadoras intraorais, avaliadas neste trabalho. E que a seleção do leito doador de enxerto ósseo autógeno intraoral deve ser principalmente julgada de acordo com o conhecimento anatômico da região eletiva e o domínio técnico/prático cirúrgico do Cirurgião / Abstract: Computed tomography (CT) three-dimensional largely solved the inconvenience of overlapping anatomical accidents common to conventional radiographic. The purpose of this study was to evaluate by cone beam computed tomography (CBCT) the region that offers larger bone volume, the ramus or chin region. Were selected according to the criteria of inclusion and non inclusion, 100 CBCT scans of individuals aged 18-89 years old males (50) and female (50) with need for surgery for autogenous grafting, belonging to a particular clinical CT. The studies were evaluated by two trained radiologists in the program OsiriX ® 4.1.2V to quantify bone volume of potential donor regions, which were evaluated by different guidelines, defining the potential volume of the donor site. Further evaluated by statistical analysis Student's t and Tukey's test, that comproove statistically significant differences (p < 0,05) between the evaluations of the same region by different methods. With the largest potential donor found in the chin region, reaching an volume average of 1,59 cm3 against 1,07 cm3 the ramus region / Doutor
6

Avaliação volumétrica por meio da tomografia computadorizada de feixe cônico, dos leitos ósseos potencialmente doadores na região de ramo e mento

Matai, Caio Vinícius Bardi [UNESP] 27 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-27Bitstream added on 2014-06-13T20:41:00Z : No. of bitstreams: 1 matai_cvb_dr_sjc.pdf: 864830 bytes, checksum: 252433555b8c9e4e86410c5c753a2004 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As tomografias computadorizadas (TCs) tridimensionais (3D) solucionaram em grande parte as inconveniências da sobreposição de estruturas anatômicas comuns aos exames radiográficos convencionais (2D). O propósito neste trabalho foi avaliar por meio da Tomografia computadorizada de feixe cônico (TCFC) qual região oferece maior volume ósseo, se a região de mento ou a região de ramo da mandíbula. Foram selecionados 100 exames de TCFC, de indivíduos com idade de 18 a 89 anos do sexo masculino (50) e do feminino (50) com necessidade de realizar cirurgia para enxertia óssea autógena. Os exames foram avaliados por dois radiologistas treinados, para quantificar o volume ósseo das regiões potencialmente doadoras, que foram avaliadas por diferentes orientações para delimitação do volume potencial do leito doador, utilizando um software para avaliação. Sendo posteriormente avaliados pela análise estatística t de Student, teste de Tukey, correlacionando as diferenças estatísticamente significantes (p < 0,05) entre a avaliação das região mensuradas, por métodos diferentes. Verificou-se o maior potencial doador encontrado na região mentual, chegando a atingir o volume médio de 1,59cm3 contra 1,07cm3 a região de ramo. Concluímos que a região mentual, entre os dentes caninos inferiores, proporciona maior volume ósseo e assim como na revisão da literatura, encontramos maior volume ósseo para a região mentual quando comparada as outras regiões doadoras intraorais, avaliadas neste trabalho. E que a seleção do leito doador de enxerto ósseo autógeno intraoral deve ser principalmente julgada de acordo com o conhecimento anatômico da região eletiva e o domínio técnico/prático cirúrgico do Cirurgião / Computed tomography (CT) three-dimensional largely solved the inconvenience of overlapping anatomical accidents common to conventional radiographic. The purpose of this study was to evaluate by cone beam computed tomography (CBCT) the region that offers larger bone volume, the ramus or chin region. Were selected according to the criteria of inclusion and non inclusion, 100 CBCT scans of individuals aged 18-89 years old males (50) and female (50) with need for surgery for autogenous grafting, belonging to a particular clinical CT. The studies were evaluated by two trained radiologists in the program OsiriX ® 4.1.2V to quantify bone volume of potential donor regions, which were evaluated by different guidelines, defining the potential volume of the donor site. Further evaluated by statistical analysis Student's t and Tukey's test, that comproove statistically significant differences (p < 0,05) between the evaluations of the same region by different methods. With the largest potential donor found in the chin region, reaching an volume average of 1,59 cm3 against 1,07 cm3 the ramus region
7

Implantes do sistema T. F. (Tissue functional) em alvéolos imediatamente após exodontia com e sem membrana de osso bovino : estudo histológico em cães /

Palma, Vinícius Canavarros. January 1998 (has links)
Orientador: Antonio César Perri de Carvalho / Resumo: O protocolo convencional para que ocorra osseointegração sugere aguardar até 6 meses para o processo de reparo alveolar, antes da colocação de um implante. Os implantes imediatos são implantes colocados em alvéolos preparados imediatamente após a exodontia. Estes implantes apresentam vantagens, pois eliminam o período de reparação do alvéolo e um tempo cirúrgico, diminuindo o período para instalação da prótese. Reduz o custo e preserva altura e largura óssea alveolar, facilitando, desta maneira, a colocação do implante em relação ao seu comprimento, largura e angulação. Neste estudo a possibilidade de colocação de um implante de titânio em alvéolos imediatamente após a extração de pré-molares inferiores foi investigada. Dezesseis implantes (9x4mm) foram colocados em alvéolos preparados imediatamente após a exodontia em oito cães. Oito implantes foram recobertos com membrana reabsorvível e a outra metade não recebeu membrana. Um espaço esteve presente nas margens laterais de todos os implantes. Este espaço foi preenchido por coágulo e sutura oclusiva foi conseguida em todos os animais. Os animais foram sacrificados nos períodos de 40, 60, 90 e 120 dias após a implantação. Avaliações histológicas dos dois grupos mostraram que houve áreas de osseointegração. Conclui-se que o implante deve ficar o máximo em contato com o osso alveolar e que a membrana reabsorvível não promoveu a regeneração óssea guiada; ao contrário, o uso de membranas pode levar a diversas complicações. A partir dos resultados obtidos muitas questões surgem, gerando a possibilidade de vários outros estudos na tentativa de responder às limitações e dúvidas suscitadas pelo presente estudo. / Abstract: The conventional osseointegration protocol calls for waiting up to 6 months for ossification of an extraction socket to heal before placing an endosseous implant. Immediate implants are implants placed into a prepared extraction socket following tooth removal. The advantages of the immediate implants include fewer surgical sessions, elimination of the waiting period for socket healing, shortened edentulous time period, reduced overall cost, as well as preservation of bone height and width. In this study the possibility of placing titanium implant directly into extraction socket immediately after extraction of mandibular premolars was investigated. Sixteen 9x4mm implants were placed into immediate extraction sockets in eight adult dogs. Eight implants were isolated with bioabsorbable membranes and eight sites served as controls. A space was present along the lateral border of all the implants. This gap was filled with clot and a primary flap closure was regarded. The animals were sacrificed 40, 60, 90 and 120 days after the implantations. Histologic evaluation of test and control specimens showed that the implants should be placed as close as possible to the alveolar crest level and the use of membranes did not imply better results; on the contrary, the use of membrane may lead to adverse complications. This study suggests that titanium implants have the potential to integrate when placed immediately after extraction of the teeth and warrants further investigation. / Mestre
8

Analise do comportamento do osso e medula hemopoetica em relação a implantes de titanio e hidroxiapatita: estudo experimental em femur de rato

Veeck, Elaine Bauer January 1994 (has links)
Tese (doutorado) -Pontificia Universidade Catolica do Rio Grande do Sul, Faculdade de Odontologia, 1994 / Made available in DSpace on 2013-07-15T21:14:22Z (GMT). No. of bitstreams: 0
9

Plasma rico em plaquetas

Macedo, Adriana Parisotto January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-21T09:15:32Z (GMT). No. of bitstreams: 1 209158.pdf: 715656 bytes, checksum: 208190e8e62ae24ad119ab5fe35f8f2a (MD5) / A regeneração óssea do osso alveolar é freqüentemente necessária para possibilitar a colocação de implantes em uma posição ideal de estética e função. As técnicas cirúrgicas de reconstrução têm como objetivo primordial uma melhora na qualidade e quantidade óssea para que o rebordo retorne as funções de suporte, tal como antes da perda do dente natural. Entre as técnicas que são utilizadas podemos citar : enxertos ósseos autógenos, alógenos xenógenos, materiais aloplásticos, regeneração tecidual guiada e distração osteogênica.
10

Análise dimensional de modelos de trabalho para a construção de próteses implanto-suportadas, obtidas através de diferentes materiais de vazamento

Volpato, Cláudia Ângela Maziero January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T06:24:45Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T23:40:03Z : No. of bitstreams: 1 179379.pdf: 1611665 bytes, checksum: 2d7b1489504bd3f3e5560bf73d013e16 (MD5) / Com o propósito de avaliar o comportamento dimensional de modelos de trabalho, utilizou-se 40 corpos de prova obtidos com gesso tipo IV, gesso tipo V, gesso reforçado por resina e resina poliuretânica. Três implantes foram posicionados paralelamente e de forma triangular na base metálica de um modelo-mestre, e as moldagens foram executadas com o auxílio de moldeiras e silicona. As distâncias AB, BC e AC (obtidas entre o centro dos implantes) foram medidas por uma máquina de medição por coordenadas. Os modelos obtidos com a resina poliuretânica apresentaram-se contraídos em AB e AC (-0,72% e -0,49%). Expansão foi encontrada nos modelos de gesso tipo V (AB: 0,002% e AC 0,29%). Os modelos de gesso tipo IV e reforçado por resina apresentaram comportamento dimensional estatisticamente similar ao modelo-mestre. Os dados da distância BC não se mostraram estatisticamente significantes.

Page generated in 0.0944 seconds