• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 64
  • 64
  • 64
  • 31
  • 25
  • 21
  • 18
  • 18
  • 18
  • 16
  • 15
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação in vitro das microdeformações em implantes curtos, com conexão protética cone morse e diferentes desenhos de roscas, convencionais e platôs

Sousa, Talitha de Cássia Silva [UNESP] 11 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:52:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-11Bitstream added on 2015-05-14T16:59:43Z : No. of bitstreams: 1 000822832.pdf: 2199125 bytes, checksum: f28423e1de0ce08490b79d83f25a7b2f (MD5) / O objetivo desse estudo in vitro foi avaliar por meio da extensometria, a distribuição de microdeformações ao redor e em dois níveis verticais de implantes curtos cone morse com roscas convencionais e implantes com platôs. Em cada bloco de poliuretano (n = 10), foram instalados dois implantes com cada tipo de desenho. Para o implante de roscas convencionais, o pilar protético sólido, foi parafusado com torque de 20 N.cm e para o implante com platôs, o pilar protético reto foi assentado no interior do implante com auxílio de um martelete. Quatro extensômetros foram colados tangenciando cada implante, posicionados diametralmente opostos. Também foi colado um extensômetro no terço médio e outro no terço apical. Carregamentos estáticos axiais de 30 kg durante 10 segundos foram realizados sobre os pilares protéticos, com auxílio do dispositivo de aplicação de carga (DAC). Os dados obtidos na extensometria foram submetidos à análise estatística ANOVA e Sidak’s (5%). Os resultados mostraram que o tipo de implante (p = 0,00029 < 0,05), a região (horizontal e vertical) (p = 0,0001 < 0,05), assim como o efeito interação (p = 0,02044 < 0,05) foram estatisticamente significantes. Conclui-se que as microdeformações são maiores para o implante com platôs e que as microdeformações horizontais são maiores comparadas as verticais de ambos os implantes / The aim of this in vitro study was to evaluate by means of strain gauge analysis, the stress distribution around and in two vertical levels of short morse taper threaded implants with morse taper threaded implants with conventional screws and Bicon plateaus implants through gauge test. In each polyurethane block (n=10), two implants with each type of design were installed. For the conventional screws implant, the solid abutment was screwed with a torque of 20 N.cm and for the plateau implant,the abument was seated right inside the implant with the aid of a hammer. Four strain gauges were glued tangent to each implant, positioned diametrically opposed. Two strain gauges were also adhered to the middle third and the other one in the apical third. Axial static loads of 30 kg were performed on the abutments during 10 seconds,with the aid of a load device (DAC). The data obtained in the gauge test werw submitted to statistical analysis using ANOVA and Sidak´s tests (5%).The results showed that the implants(p=0.00029 < 0.05), the region(horizontal and vertical) (p= 0.0001 <0.05), as well as the interaction effect(p=0.02044<0.05) were statistically significant. It follows that themicro-strains are greatest for the implant with plateaus and horizontal micro-strain are larger compared to both the vertical implants
12

Regeneração óssea vertical usando barreira não-porosa de politetrafluoretileno em implantes osteointegrados inseridos parcialmente na tíbia de coelhos /

Macedo, Nelson Luiz de. January 1999 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Francisco Fernando Todescan / Banca: Koto Nake / Banca: Marco Antonio Bottino / Banca: Yasmin Rodarte Carvalho / Resumo: O objetivo deste estudo foi avaliar a possibilidade de obter regeneração óssea dirigida utilizando-se uma barreira fisica não-porosa de PTFE em implantes osteointegrados, parcialmente inseridos na tíbia de coelhos, e as característícas da interface entre implantes de titânio, revestidos ou não com plasma de titânio, e o tecido ósseo regenerado. Vinte implantes Screw-Vent foram instalados nas tíbias direita e esquerda, emergindo 3,0 mm do topo da crista óssea, criando um defeito ósseo horizontal. No lado experimental, os implantes e o tecido ósseo adjacente foram cobertos com uma barreira não-porosa de PTFE. A análise histológica mostrou que todos os implantes estavam em contato direto com o tecido ósseo. As medidas histológicas mostraram um ganho ósseo médio em altura de 2,15 mm e 2,42 mm nos defeitos com barreira, e de 1,95 mm e 0,43 mm nos controles com revestimento de plasma de titânio e com tratamento ácido da superficie, respectivamente. Os resultados sugeriram que a colocação de implantes emergindo 3,0 mm do defeito ósseo pode resultar em crescimento ósseo vertical e que o osso regenerado foi capaz de osteointegrar os implantes. A utilização da barreira parece ser crítica quando se utiliza o implante de titânio com a superficie tratada por ácido / Abstract: The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted / Doutor
13

Implantes do sistema T. F. (Tissue functional) em alvéolos imediatamente após exodontia com e sem membrana de osso bovino: estudo histológico em cães

Palma, Vinícius Canavarros [UNESP] January 1998 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 1998Bitstream added on 2014-06-13T19:30:05Z : No. of bitstreams: 1 palma_vc_me_araca.pdf: 1901669 bytes, checksum: 33ec6f01ba3fb930bfa9ba761cd9b128 (MD5) / O protocolo convencional para que ocorra osseointegração sugere aguardar até 6 meses para o processo de reparo alveolar, antes da colocação de um implante. Os implantes imediatos são implantes colocados em alvéolos preparados imediatamente após a exodontia. Estes implantes apresentam vantagens, pois eliminam o período de reparação do alvéolo e um tempo cirúrgico, diminuindo o período para instalação da prótese. Reduz o custo e preserva altura e largura óssea alveolar, facilitando, desta maneira, a colocação do implante em relação ao seu comprimento, largura e angulação. Neste estudo a possibilidade de colocação de um implante de titânio em alvéolos imediatamente após a extração de pré-molares inferiores foi investigada. Dezesseis implantes (9x4mm) foram colocados em alvéolos preparados imediatamente após a exodontia em oito cães. Oito implantes foram recobertos com membrana reabsorvível e a outra metade não recebeu membrana. Um espaço esteve presente nas margens laterais de todos os implantes. Este espaço foi preenchido por coágulo e sutura oclusiva foi conseguida em todos os animais. Os animais foram sacrificados nos períodos de 40, 60, 90 e 120 dias após a implantação. Avaliações histológicas dos dois grupos mostraram que houve áreas de osseointegração. Conclui-se que o implante deve ficar o máximo em contato com o osso alveolar e que a membrana reabsorvível não promoveu a regeneração óssea guiada; ao contrário, o uso de membranas pode levar a diversas complicações. A partir dos resultados obtidos muitas questões surgem, gerando a possibilidade de vários outros estudos na tentativa de responder às limitações e dúvidas suscitadas pelo presente estudo. / The conventional osseointegration protocol calls for waiting up to 6 months for ossification of an extraction socket to heal before placing an endosseous implant. Immediate implants are implants placed into a prepared extraction socket following tooth removal. The advantages of the immediate implants include fewer surgical sessions, elimination of the waiting period for socket healing, shortened edentulous time period, reduced overall cost, as well as preservation of bone height and width. In this study the possibility of placing titanium implant directly into extraction socket immediately after extraction of mandibular premolars was investigated. Sixteen 9x4mm implants were placed into immediate extraction sockets in eight adult dogs. Eight implants were isolated with bioabsorbable membranes and eight sites served as controls. A space was present along the lateral border of all the implants. This gap was filled with clot and a primary flap closure was regarded. The animals were sacrificed 40, 60, 90 and 120 days after the implantations. Histologic evaluation of test and control specimens showed that the implants should be placed as close as possible to the alveolar crest level and the use of membranes did not imply better results; on the contrary, the use of membrane may lead to adverse complications. This study suggests that titanium implants have the potential to integrate when placed immediately after extraction of the teeth and warrants further investigation.
14

Avaliação in vitro das microdeformações em implantes curtos, com conexão protética cone morse e diferentes desenhos de roscas, convencionais e platôs /

Sousa, Talitha de Cássia Silva. January 2014 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Francisley Ávila Souza / Banca: Eduardo Bressiani / Resumo: O objetivo desse estudo in vitro foi avaliar por meio da extensometria, a distribuição de microdeformações ao redor e em dois níveis verticais de implantes curtos cone morse com roscas convencionais e implantes com platôs. Em cada bloco de poliuretano (n = 10), foram instalados dois implantes com cada tipo de desenho. Para o implante de roscas convencionais, o pilar protético sólido, foi parafusado com torque de 20 N.cm e para o implante com platôs, o pilar protético reto foi assentado no interior do implante com auxílio de um martelete. Quatro extensômetros foram colados tangenciando cada implante, posicionados diametralmente opostos. Também foi colado um extensômetro no terço médio e outro no terço apical. Carregamentos estáticos axiais de 30 kg durante 10 segundos foram realizados sobre os pilares protéticos, com auxílio do dispositivo de aplicação de carga (DAC). Os dados obtidos na extensometria foram submetidos à análise estatística ANOVA e Sidak's (5%). Os resultados mostraram que o tipo de implante (p = 0,00029 < 0,05), a região (horizontal e vertical) (p = 0,0001 < 0,05), assim como o efeito interação (p = 0,02044 < 0,05) foram estatisticamente significantes. Conclui-se que as microdeformações são maiores para o implante com platôs e que as microdeformações horizontais são maiores comparadas as verticais de ambos os implantes / Abstract: The aim of this in vitro study was to evaluate by means of strain gauge analysis, the stress distribution around and in two vertical levels of short morse taper threaded implants with morse taper threaded implants with conventional screws and Bicon plateaus implants through gauge test. In each polyurethane block (n=10), two implants with each type of design were installed. For the conventional screws implant, the solid abutment was screwed with a torque of 20 N.cm and for the plateau implant,the abument was seated right inside the implant with the aid of a hammer. Four strain gauges were glued tangent to each implant, positioned diametrically opposed. Two strain gauges were also adhered to the middle third and the other one in the apical third. Axial static loads of 30 kg were performed on the abutments during 10 seconds,with the aid of a load device (DAC). The data obtained in the gauge test werw submitted to statistical analysis using ANOVA and Sidak's tests (5%).The results showed that the implants(p=0.00029 < 0.05), the region(horizontal and vertical) (p= 0.0001 <0.05), as well as the interaction effect(p=0.02044<0.05) were statistically significant. It follows that themicro-strains are greatest for the implant with plateaus and horizontal micro-strain are larger compared to both the vertical implants / Mestre
15

Osseointegração de implantes porosos de titânio submetidos ao tratamento biomimético /

Leite, Daniel de Oliveira. January 2011 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Banca: Yasmin Rodarte Carvalho / Banca: Renata Falchete do Prado / Resumo: Atualmente, as pesquisas em Implantodontia enfatizam modificações na superfície dos implantes, visando melhorar a osseointegração. Nesse sentido, o presente estudo teve como objetivo avaliar a influência da porosidade, bem como do tratamento biomimético (TB), na osteogênese in vivo em implantes de titânio. Foram confeccionados, por meio da metalurgia do pó, implantes de titânio puro grau 2, que foram divididos em seis grupos: a) G1: denso; b) G2: 40% de porosidade; c) G3: 50% de porosidade; d) G4: G1 + TB; e) G5: G2 + TB; f) G6: G3 + TB. Inicialmente, as amostras foram caracterizadas por análise metalográfica e por espectroscopia por energia dispersiva (EDS). Em seguida, os implantes foram inseridos nas tíbias de dezesseis coelhos da raça Nova Zelândia, para avaliar a reparação óssea peri-implantar, por meio de análise histológica e histomorfométrica. Como padronização, os implantes G1, G2 e G3 foram inseridos na tíbia direita e G4, G5 e G6 na esquerda. Quatro coelhos, selecionados aleatoriamente, foram submetidos à eutanásia, 01, 02, 04 e 08 semanas após a cirurgia. Os dados da análise metalográfica foram submetidos ao teste de Kruskal-Wallis e a análise histomorfométrica foi avaliada pelos testes ANOVA e Tukey. Os resultados da metalografia confirmaram porosidade de 40 e 50%, e revelaram poros com tamanho médio de 370 μm e interconexão entre os mesmos. Na análise por EDS foi observada a presença de íons Ca e P, caracterizando o sucesso do TB. Na análise histológica observou-se neoformação óssea, inclusive para o interior dos poros, independente do tipo de implante ou do tempo. Na análise histomorfométrica, verificou-se maior neoformação óssea em G5 e G6, e menor em G1, sendo que ambas as condições mostraram diferença estaticamente significante em relação aos demais grupos. Concluiu-se que o TB associado à porosidade exerce influência positiva na neoformação óssea. / Abstract: Researches in implantodontology have been recently focusing on implant surface modifications aiming to improve osseointegration. Thus, the purpose of the present study was to evaluate in vivo the influence of titanium implants surface porosity and surface biomimetic treatment (BT) on osteogenesis. Grade 2 pure titanium implants were fabricated by means of powder metallurgy and divided into six groups: a) G1: dense; b) G2: porosity of 40%; c) G3: porosity of 50%; d) G4: G1 + BT; e) G5: G2 + BT; and f) G6: G3 + BT. The samples were initially characterized by metallographic analysis and energy-dispersive spectroscopy (EDS). The implants were then placed into the tibia of sixteen New Zealand rabbits in order to evaluate the peri-implant bone repair by means of histological and histomorphometric analyses. As standardization, implants from groups G1, G2 and G3 were inserted into right tibias; while G4, G5 and G6 into left ones. Four randomly chosen rabbits underwent euthanasia 01, 02, 04 and 8 weeks after surgery. The results from metallographic analysis were analyzed by Kruskal-Wallis test and the histomorphometric results by ANOVA and Tukey tests. Metallographic results confirmed porosity between 40 and 50%, and revealed mean pore size of 370 μm and interconnection among them. EDS analysis detected the presence of Ca and P ions, confirming BT success. Bone neoformation, including into the pores, was detected by the histological analysis regardless the type of implant or evaluated period. By the histomorphometric analysis, bone neoformation was statistically greater for G5 and G6 and statistically lesser for G1 in comparison to the other groups. It was concluded that BT associated with porosity exerts positive influence on bone neoformation. / Mestre
16

Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamente /

Cardoso, Leandro de Carvalho. January 2008 (has links)
Orientador: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Daniele Botticelli / Banca: Hugo Alexandre de Souza / Banca: Maurício Zardo / Resumo: O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II - Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III - experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / Abstract: The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups. / Doutor
17

Prótese parcial removível de extremidade livre associada a um implante osseointegrado: influência do ligamento periodontal na distribuição interna das tensões

Archangelo, Carlos Marcelo [UNESP] 06 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-06Bitstream added on 2014-06-13T20:58:51Z : No. of bitstreams: 1 archangelo_cm_me_araca.pdf: 2727002 bytes, checksum: 70ce356e1f90c64c2cd8afe4655ae354 (MD5) / Universidade Estadual Paulista (UNESP) / Em função da adoção de hipóteses simplificadoras nos estudos através do método dos elementos finitos (MEF), os dados sobre a menor solicitação das estruturas de suporte na associação da prótese parcial removível de extremidade livre (PPREL) com um implante osseointegrado são inconclusivos. Assim, foi objetivo do presente estudo avaliar, através do MEF bidimensional, a distribuição interna das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado, em função da reprodução homogênea e não-homogênea do ligamento periodontal (LP). Para isso, 6 modelos (M) foram criados no programa AutoCAD 2005 (Autodesk Inc.; USA), representando: MA - hemiarco contendo somente o dente 33 e o rebordo desdentado para distal; MB - semelhante ao A, com uma PPREL substituindo os dentes ausentes; MC - semelhante ao B, com um implante (Sistema Bränemark - 3,75 mm x 10,0 mm) na região retromolar suportando a base da prótese; MD, ME e MF semelhantes aos modelos A, B e C, respectivamente, com exceção do LP, que foi modelado de forma não-homogênea, com a representação de 4 conjuntos de fibras: fibras da crista, horizontais, oblíquas e apicais. Após isso, os modelos foram exportados para o programa de elementos finitos ANSYS 8.0, e carregados com forças estritamente verticais de 50N em cada ponta de cúspide, fracionadas em 5 pontos de 10N. Os mapas gerais de tensões evidenciaram máxima e mínima concentração de tensões de (em MPa): MA (58,976 e 0,0045); MB (77,863 e 0,0551); MC (207,195 e 0,0057); MD (110,33 e 0,0137); ME (191,36 e 0,0044) e MF (326,60 e 0,0076), com deslocamento máximo de (mm): MA (0,0631); MB (0,1263); MC (0,1142); MD (0,2709); ME (0,1960) e MF (0,2019). / The application of many hypotheses in a finite element analysis (FEA) has been critical to obtain precise results in the removable partial denture treatment associated with an osseointegrated implant. In view of that, the purpose of the present study was to evaluated, through 2-D finite element analysis, the stress distribution in the support structures of a free-end saddle removable partial denture (RPD) associated with an osseointegrated implant, in function of the homogenous and non-homogenous condition for the periodontal ligament. For this, 6 models (M) were created in the AutoCAD software (Autodesk Inc.; USA), representing: MA - hemiarch contain only the natural tooth (33) and edentulous space in the posterior region; MB - similar to MA, with an RPD replacing the absent teeth; MC - similar to MB, with an osseointegrated implant (Branemark System - 3.75 x 10.00 mm) positioned in a posterior region in order to support the RPD base; MD, ME and MF - identical to MA, MB and MC, respectively; however, in these models, the periodontal ligament was considered an non-homogenous structure by the incorporation of four fibers groups in a sagital plane: alveolar crest fibers, horizontals, oblique, and apical fibers. After this, the models were exported to the finite element program (ANSYS 8.0) and loaded with verticals forces (50N) in each cusp. The results showed maximum and minimum stress (MPa): MA (58.976 and 0.0045); MB (77.863 and 0.0551); MC (207.195 and 0.0057); MD (110.33 and 0.0137); ME (191.36 and 0.0044) and MF (326.60 and 0.0076). The maximum displacement (mm) was: MA (0.0631); MB (0.1263); MC (0.1142); MD (0.2709); ME (0.2019) and MF (0.2019). (Complete abstract click eletronic address below)
18

Influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas

Delben, Juliana Aparecida [UNESP] 23 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-23Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 delben_ja_me_araca.pdf: 1525895 bytes, checksum: 08b0efeaeab10edf292abba40231b759 (MD5) / A longevidade das próteses e implantes é dependente da adequada adaptação entre os componentes bem como da distribuição favorável de forças às estruturas de suporte. O afrouxamento do parafuso de retenção é uma falha mecânica comumente observada devido à redução da pré-carga gerada no parafuso de retenção, responsável pela manutenção da estabilidade da união parafusada e resistência às forças que tendem a separar os componentes. O objetivo do estudo foi avaliar a influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas, submetidos a sucessivos reapertos e ciclagem mecânica. Foram confeccionadas 60 coroas de acordo com os grupos de estudo (n=12): Grupo I - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metalocerâmicas, Grupo II - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metaloplásticas, Grupo III – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metalocerâmicas, Grupo IV – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metaloplásticas, Grupo IV - pilares de zircônia obtidos pelo sistema CAD/CAM (computer-aided design/computer-aided manufacturing) para obtenção de coroas cerâmicas. As coroas foram unidas a implantes de hexágono externo por meio de parafuso de retenção quadrado de ouro com torque de inserção de 35 Ncm e submetidas à ciclagem mecânica com aplicação de carregamento vertical dinâmico de 50N a uma freqüência de 2Hz. Valores de destorque foram mensurados antes da ciclagem mecânica e após cada período de 1x105 ciclos seguido de reaperto com 35 Ncm de modo a completar 1x106 ciclos. Mensurações da desadaptação vertical na interface pilar-implante foram realizadas através de estereomicroscopia inicialmente e ao final da... / The longevity of prostheses and implants depends on fit betweenn components as well as adequate forces distribution to supporting structures. Retaining screw loosening is a commom mechanical complication due to preload reduction that provides joint stability and resistance to separating forces. The aim of this study was to evaluate the influence of different abutments and veneering materials on preload maintenance of retaining screw of implant-supported crowns submitted to repeated tightening and mechanical cycling. Sixty crowns were obtained according to the groups (n=12): Group I – Gold UCLA abutment cast in gold allow with ceramic vennering, Group II – Gold UCLA abutment cast in gold alloy with resin veneering, Group III – UCLA abutment cast in titanium with ceramic veneering, Group IV – UCLA abutment cast in titanium with resin veneering, and Group V – zirconia abutment obtained by CAD/CAM (computer-aided desing/computer-aided manufacturing) system with ceramic veneering. The crowns were attached to external hexagon implants by gold retaining screws with insertion torque of 35Ncm. The replicas were submitted to mechanical cycling with vertical dinamic loading of 50N at 2Hz. Detorque measurements were performed initially and after each period of 1x105 cycles followed by retightening of retaining screw with 35Ncm until 1x106 cycles. Measurements of vertical misfit on abutment-implant interface were performed through estereomicroscopy initially and after mechanical cycling. Data were submitted to analysis of variance, Fisher’s exact test, paired t test, Student’s t-test and Pearson correlation (P<.05). All detorque measurements were lower than insertion torque of 35Ncm. There was statistically significant difference among the 5 groups (P<.05) for detorque values obtained initially and after mechanical cycling. However, there was no statistically significant difference... (Complete abstract click electronic access below)
19

Desenvolvimento e fabricação de um protótipo de implante odontológico a partir de osso bovino como material de preenchimento em cirurgias de levantamento de seio maxilar

Stares, Steferson Luiz January 2006 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Mecânica / Made available in DSpace on 2012-10-22T15:57:49Z (GMT). No. of bitstreams: 1 228760.pdf: 5650800 bytes, checksum: a28c8ed686cd495bcf66e3a07d363ff0 (MD5) / O presente estudo tem como objetivo o desenvolvimento de um implante (parafuso+porca) manufaturado por usinagem e tendo como matéria-prima osso cortical bovino mineral desproteinizado (OBMD). O implante foi desenvolvido para futuro uso clínico em substituição a enxertos ósseos nas técnicas de levantamento de seio maxilar. Avaliou-se também as possíveis alterações nas propriedades do OBMD, tanto em estado desengordurado (G1) como esterilizado (G2), através de ensaios mecânicos para medir o poder de fixação dos parafusos. Cães fêmeas da raça Bangor Beagle foram utilizados neste experimento. Por meio de um acesso cirúrgico, a tíbia foi exposta e nela foram usinadas com orientação diagonal em relação ao eixo longitudinal do osso, cinco roscas internas passantes. Os implantes esterilizados foram inseridos totalmente no osso. Após um período de observação de 120 dias, os implantes foram removidos, processados e avaliados histologicamente. Análises histológicas demonstraram evidente neo-formação de tecido ósseo à interface osso-implante. Nos ensaios mecânicos e análise estatística entre os grupos G1 e G2 investigados foram observadas diferenças significativas (p<< 0,05).
20

Análise comparativa da topografia e presença de impurezas de implantes dentais com superfície texturizada por meio de microscopia eletrônica de varredura (MEV)

Castro, Kavio Narciso de Oliveira January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-21T13:08:28Z (GMT). No. of bitstreams: 1 203835.pdf: 10797340 bytes, checksum: bfd0a2cbac605c338cdfb3cadf47f950 (MD5) / O objetivo desta análise comparativa foi observar qualitativamente, por meio de Microscopia Eletrônica de Varredura (MEV), as variações microscópicas topográficas e a presença de impurezas em cinco fabricantes de implantes osteointegráveis submetidos a diferentes processos de texturização: Conexão (Grupo 1); 3i (Grupo 2); Neodent (Grupo 3); SIN (Grupo 4); Titanium fix (Grupo 5). De acordo com os resultados foi possível concluir que, no aspecto topográfico os fabricantes SIN (G4) e 3i (G2) foram estatisticamente equivalentes, em um nível de significância de 1% e melhores que todos os demais, exibindo uma característica topográfica desejável. Os fabricantes Conexão (G1), Neodent (G3) e Titanium fix (G5) mostraram diferenças significantes entre si, em um nível de significância de 1% e padrões de texturização variáveis. No aspecto presença de impurezas os fabricantes Neodent (G3) e Conexão (G1) foram equivalentes entre si, em um nível de significância de 1% e melhores que todos os demais, mostrando superfícies mais livres de impurezas que todos os demais. Os fabricantes SIN (G4) e 3i (G2) foram equivalentes entre si, em um nível de significância de 1%, exibindo superfícies com uma certa quantidade de impurezas e melhores que o fabricante Titanium fix, que se mostrou inferior a todos os demais, exibindo superfícies com grande quantidade de impurezas.

Page generated in 0.1031 seconds