• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 5
  • 5
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões: estudo pelo método dos elementos finitos tridimensionais

Almeida, Daniel Augusto de Faria [UNESP] 21 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-21Bitstream added on 2014-06-13T19:58:21Z : No. of bitstreams: 1 almeida_daf_me_araca.pdf: 686399 bytes, checksum: 50ad249856d1640af8c25dd2dcb4adb5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento e uso de intermediários angulados, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, o propósito do presente estudo foi analisar a influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados seis modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco ósseo e a presença de um implante (4,0x10 mm) com diferentes angulações (0º, 17º e 30º) e tipos de conexão (Hexágono externo e cone morse), com coroa metalo-cerâmica. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (quatro para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho... / The biomechanical behavior of an osseointegrated dental implant plays an important role in the longevity. The anatomical limitations sometimes require the placement of implants with angles outside the considered ideal for prosthetic rehabilitation, with higher stress concentration and resorption in cortical bone around the implant. Thus, in some situations, the professional should planning careful the treatment and use the abutment, analyzing the prosthetic connection which best fits the clinical situation. Therefore, the purpose of this study was to analyze the influence of the implant angulation with different types of prosthetic connection on the stress distribution, by three-dimensional finite element method. Six three-dimensional models were made with the aid of the graphical modeling and SolidWorks 2010 Rhinoceros 4.0 and InVesalius.Each model was composed of a bone blockwith an implant (4.0 x 10 mm) with different angulations (0, 17 and 30) and connection types (Hexagon external and Morse taper) with metal-ceramic crown. After generation of the geometries, the models were imported into the pre-and post-processing finite element FEMAP 10.2, where we generated finite element meshes, boundary and loading conditions. The load was applied axial 200N and 100N obliquely to the occlusal surface of crowns. This total load was divided between the cusps (four for the axial load and two oblique lingual to the load). Then, the analysis was generated in and exported 10.2 FEMAP software for calculation in finite element program NeiNastran version 9.2, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and maximum principal stress. The maps for... (Complete abstract click electronic access below)
2

Influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas

Delben, Juliana Aparecida [UNESP] 23 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-23Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 delben_ja_me_araca.pdf: 1525895 bytes, checksum: 08b0efeaeab10edf292abba40231b759 (MD5) / A longevidade das próteses e implantes é dependente da adequada adaptação entre os componentes bem como da distribuição favorável de forças às estruturas de suporte. O afrouxamento do parafuso de retenção é uma falha mecânica comumente observada devido à redução da pré-carga gerada no parafuso de retenção, responsável pela manutenção da estabilidade da união parafusada e resistência às forças que tendem a separar os componentes. O objetivo do estudo foi avaliar a influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas, submetidos a sucessivos reapertos e ciclagem mecânica. Foram confeccionadas 60 coroas de acordo com os grupos de estudo (n=12): Grupo I - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metalocerâmicas, Grupo II - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metaloplásticas, Grupo III – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metalocerâmicas, Grupo IV – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metaloplásticas, Grupo IV - pilares de zircônia obtidos pelo sistema CAD/CAM (computer-aided design/computer-aided manufacturing) para obtenção de coroas cerâmicas. As coroas foram unidas a implantes de hexágono externo por meio de parafuso de retenção quadrado de ouro com torque de inserção de 35 Ncm e submetidas à ciclagem mecânica com aplicação de carregamento vertical dinâmico de 50N a uma freqüência de 2Hz. Valores de destorque foram mensurados antes da ciclagem mecânica e após cada período de 1x105 ciclos seguido de reaperto com 35 Ncm de modo a completar 1x106 ciclos. Mensurações da desadaptação vertical na interface pilar-implante foram realizadas através de estereomicroscopia inicialmente e ao final da... / The longevity of prostheses and implants depends on fit betweenn components as well as adequate forces distribution to supporting structures. Retaining screw loosening is a commom mechanical complication due to preload reduction that provides joint stability and resistance to separating forces. The aim of this study was to evaluate the influence of different abutments and veneering materials on preload maintenance of retaining screw of implant-supported crowns submitted to repeated tightening and mechanical cycling. Sixty crowns were obtained according to the groups (n=12): Group I – Gold UCLA abutment cast in gold allow with ceramic vennering, Group II – Gold UCLA abutment cast in gold alloy with resin veneering, Group III – UCLA abutment cast in titanium with ceramic veneering, Group IV – UCLA abutment cast in titanium with resin veneering, and Group V – zirconia abutment obtained by CAD/CAM (computer-aided desing/computer-aided manufacturing) system with ceramic veneering. The crowns were attached to external hexagon implants by gold retaining screws with insertion torque of 35Ncm. The replicas were submitted to mechanical cycling with vertical dinamic loading of 50N at 2Hz. Detorque measurements were performed initially and after each period of 1x105 cycles followed by retightening of retaining screw with 35Ncm until 1x106 cycles. Measurements of vertical misfit on abutment-implant interface were performed through estereomicroscopy initially and after mechanical cycling. Data were submitted to analysis of variance, Fisher’s exact test, paired t test, Student’s t-test and Pearson correlation (P<.05). All detorque measurements were lower than insertion torque of 35Ncm. There was statistically significant difference among the 5 groups (P<.05) for detorque values obtained initially and after mechanical cycling. However, there was no statistically significant difference... (Complete abstract click electronic access below)
3

Influência do tipo de conexão pilar/implante na manutenção da pré-carga de parafusos de retenção e na desadaptação vertical da coroa protética antes e após ciclagem mecânica

Aguiar, Juliana Ribeiro Pala Jorge de [UNESP] 02 May 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-02Bitstream added on 2014-06-13T19:24:17Z : No. of bitstreams: 1 aguiar_jrpj_dr_araca.pdf: 843042 bytes, checksum: f640ef7de226d005134afbe1456c4ddf (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone... / Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear... (Complete abstract click electronic access below)
4

Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea: estudo pelo método dos elementos finitos tridimensionais

Antenucci, Rosse Mary Falcón [UNESP] 02 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-02Bitstream added on 2014-06-13T19:24:18Z : No. of bitstreams: 1 antenucci_rmf_dr_araca.pdf: 994627 bytes, checksum: 0fe6227d507931e16135dd308b4ca65c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... / A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below)
5

Avaliação da distribuição de tensões em próteses do tipo protocolo mandibular para carregamento imediato por meio do MEF-3D

Ferreira, Mayara Barbosa [UNESP] 30 August 2013 (has links) (PDF)
Made available in DSpace on 2014-08-27T14:36:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-30Bitstream added on 2014-08-27T15:57:10Z : No. of bitstreams: 1 000749476.pdf: 2329747 bytes, checksum: 03a2fd6929cc767c1fa0d33bd2730969 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Proposição: Esse estudo comparou a distribuição das tensões em 3 diferentes tipos de próteses fixas implanto-suportadas mandibulares para carregamento imediato com o protocolo convencional de dois estágios cirúrgicos, no que diz respeito à distribuição de tensões, por meio do Método de Elementos Finitos tridimensional não linear. Materiais e Métodos: Quatro modelos de mandíbula humana edêntula suporte de prótese fixa implanto-suportada com quatro implantes foram construídos. Os modelos foram divididos em 4 grupos: Grupo A (controle) – os implantes foram rigidamente esplintados por meio de infraestrutura metálica, e submetidos ao protocolo de carregamento convencional de dois estágios cirúrgicos; no Grupo B – os implantes não foram rigidamente esplintados (esplintagem por meio de resina acrílica), e submetidos ao protocolo de carregamento imediato; no Grupo C – os implantes foram rigidamente esplintados por meio de infraestrutura metálica e submetidos ao protocolo de carregamento imediato; no Grupo D – os implantes não foram rigidamente esplintados (esplintagem por meio de resina acrílica), sendo que foi inserido na região do cantilever uma barra-distal pré-fabricada, e foram submetidos ao protocolo de carregamento imediato.Para simular a condição de carregamento imediato dos implantes (Grupos B, C e D), elementos de contato não linear e friccional foram usados. O coeficiente de fricção de 0,3 ? foi utilizado entre o osso e o implante. No modelo A foi considerado um contato colado na interface osso-implante. Os modelos foram suportados pelos músculos da mastigação e pela articulação temporomandibular. Uma carga de 100 N no sentido oblíquo... / Purpose: This study compared the stress distribution between 3 different mandibular full-arch implant-supported fixed dentures submitted to immediate loading and conventional full-arch implant-supported fixed denture through three-dimensional finite element analysis. Materials and Methods: Four models of edentulous human mandible were fabricated with 4 implants for restoration with full-arch implant-supported fixed denture. The models were divided into 4 groups: Group A (control) – implants were splinted with metallic framework and submitted to conventional loading protocol after 2 surgical steps, Group B – implants were splinted with acrylic resin and submitted to immediate loading, Group C – implants were splinted with metallic framework and submitted to immediate loading, and Group D – implants were splinted with acrylic resin and submitted to immediate loading with a prefabricated distal bar positioned in the cantilever region. Non-linear and frictional contact elements were used to simulate immediate loading (Groups B, C and D). The coefficient of friction ?=0.3 was established between bone and implant. Direct contact at bone implant interface was assumed in the model A. All models were supported by masticatory muscles and the temporomandibular joint. Oblique load of 100N was applied on mandibular first molar. The values of von Mises (?vM) and maximum (?max) and minimum (?min) principal stresses (in MPa) were obtained. Results: Group A presented the lowest stress values (?vM=147, ?max=102 e ?min=-131 MPa) while group D showed the highest values (?vM=904, ?max=685 e ?min=-1481 MPa). In bone tissue, the groups submitted... / FAPESP: 10/09857-3 / FAPESP: 11/15172-6
6

Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón. January 2011 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Pedro Yoshito Noritomi / Banca: Paulo Sérgio Perri de Carvalho / Banca: Fellippo Ramos Verri / Banca: Marcelo Ferraz Mesquita / Banca: Pedro Tortamano Neto / Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below) / Doutor
7

Avaliação da influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões : estudo pelo método dos elementos finitos tridimensionais /

Almeida, Daniel Augusto de Faria. January 2011 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Banca: Estevão Tomomitsu Kimpara / Banca: Marcelo Coelho Goiato / Resumo: O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento e uso de intermediários angulados, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, o propósito do presente estudo foi analisar a influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados seis modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco ósseo e a presença de um implante (4,0x10 mm) com diferentes angulações (0º, 17º e 30º) e tipos de conexão (Hexágono externo e cone morse), com coroa metalo-cerâmica. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (quatro para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The biomechanical behavior of an osseointegrated dental implant plays an important role in the longevity. The anatomical limitations sometimes require the placement of implants with angles outside the considered ideal for prosthetic rehabilitation, with higher stress concentration and resorption in cortical bone around the implant. Thus, in some situations, the professional should planning careful the treatment and use the abutment, analyzing the prosthetic connection which best fits the clinical situation. Therefore, the purpose of this study was to analyze the influence of the implant angulation with different types of prosthetic connection on the stress distribution, by three-dimensional finite element method. Six three-dimensional models were made with the aid of the graphical modeling and SolidWorks 2010 Rhinoceros 4.0 and InVesalius.Each model was composed of a bone blockwith an implant (4.0 x 10 mm) with different angulations (0, 17 and 30) and connection types (Hexagon external and Morse taper) with metal-ceramic crown. After generation of the geometries, the models were imported into the pre-and post-processing finite element FEMAP 10.2, where we generated finite element meshes, boundary and loading conditions. The load was applied axial 200N and 100N obliquely to the occlusal surface of crowns. This total load was divided between the cusps (four for the axial load and two oblique lingual to the load). Then, the analysis was generated in and exported 10.2 FEMAP software for calculation in finite element program NeiNastran version 9.2, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and maximum principal stress. The maps for... (Complete abstract click electronic access below) / Mestre
8

Masticatory function in partially edentulous patients after rehabilitation with removable and fixed prosthesis over osseointegrated implants = Função mastigatória de pacientes parcialmente edêntulos após reabilitação com próteses removíveis e fixas sobre implantes osseointegrados / Função mastigatória de pacientes parcialmente edêntulos após reabilitação com próteses removíveis e fixas sobre implantes osseointegrados

Gonçalves, Thais Marques Simek Vega, 1980- 23 October 2013 (has links)
Orientador: Renata Cunha Matheus Rodrigues-Garcia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T21:43:34Z (GMT). No. of bitstreams: 1 Goncalves_ThaisMarquesSimekVega_D.pdf: 2684657 bytes, checksum: b1b361a499cc2e74dc84aa2b63d2ae75 (MD5) Previous issue date: 2013 / Resumo: Estudos revelam melhora na mastigação após o uso de próteses sobre implantes osseointegrados. Entretanto, poucos são aqueles que avaliam a mastigação de pacientes parcialmente edêntulos, comparando a função mastigatória após a reabilitação por meio de diferentes próteses parciais, o qual foi o objetivo deste ensaio clínico pareado. Para tanto, foram selecionados 12 voluntários (8 gênero feminino, idade média 62.6 ± 7.8 anos), apresentando edentulismo total superior e parcial inferior (classe I de Kennedy), os quais receberam, de forma sequencial, próteses parciais removíveis (PPR), PPR com encaixe implanto-retido (PPRI) e prótese parcial fixa sobre implantes (PPFI). Todos os tratamentos foram realizados na mandíbula e utilizados por 2 meses antes da avaliação mastigatória, enquanto a maxila recebeu uma nova prótese total que foi utilizada durante todo o estudo. A mastigação foi avaliada por meio da mensuração da performance mastigatória (PM), índice de trituração dos alimentos (ITA), força máxima de mordida (FMM), espessura dos músculos masseter e temporal, movimento mastigatório, limiar de deglutição (LD), habilidade mastigatória, estado nutricional, qualidade de vida (QV) e satisfação do paciente. Foi realizada a análise exploratória dos dados e aplicada análise de variância para medidas repetidas seguido de teste de Tukey-Kramer para as comparações múltiplas entre os tratamentos. Todas as análises foram realizadas utilizando SAS software (release 9.1, 2003; SAS Institute Inc., Cary, USA) (p ? 0.05). A PM melhorou consideravelmente após o uso de PPRI e PPFI com aumento de 85% e 87%, respectivamente. Resultados similares foram observados em relação ao ITA e à FMM com aumento (p ? 0.0001) de 91% e 62% no ITA de 79% e 62% na FMM após o uso de PPRI e PPFI, respectivamente. Independente do tipo de prótese, o uso de PPRI e PPFI aumentou a espessura do masseter durante a contração voluntária máxima (p ? 0.0001) e alterou o movimento mastigatório, reduzindo o tempo total do ciclo, bem como a duração das fases de abertura e fechamento (p ? 0.05). A habilidade mastigatória melhorou após o uso da PPRI e PPFI, independente do alimento avaliado. O LD foi alterado pelo tratamento reabilitador, com redução no número de ciclos e tamanho da partícula triturada, sendo os menores valores observados com o uso da PPFI. Houve aumento no consumo de fibras (p = 0.007), cálcio (p = 0.001) e ferro (p = 0.02) após o uso de PPFI, além da redução no consumo de alimentos com altos níveis de colesterol (p = 0.02). A satisfação aumentou (p ? 0.05) e o impacto da saúde oral na QV reduziu, tanto no score geral (p = 0.04) quanto no domínio de dor física (p = 0.02) após o uso da PPFI. A reabilitação de pacientes parcialmente edêntulos com PPRI e PPFI melhorou significativamente a função mastigatória e a magnitude do efeito relacionou-se ao tipo de prótese / Abstract: Studies revealed the masticatory improvement after the use of prosthesis over dental implants. However, few are those who evaluated the chewing of partially edentulous patients, comparing the masticatory function after treatment with different partial dentures, which was the aim of this paired clinical trial. Therefore, 12 volunteers (8 females, mean age 62.6 ± 7.8 years) presenting total edentulism in maxilla and partial edentulism in the mandible (Kennedy class I) were selected and received, in a sequential way, a conventional removable partial dentures (RPD), implant-retained partial dentures (IRPD) and implant fixed partial denture (IFPD). All treatment were assembled in the mandible and used for 2 months, while the edentulous maxilla received a new complete denture which was used throughout the study. Mastication was assessed by measuring masticatory performance (MP), food comminution index (FCI), maximum bite force (MBF), masseter and temporal muscle thickness, chewing movements, swallowing threshold (ST), masticatory ability, nutritional status, quality of life (QOL) and patient satisfaction. Data were analyzed and repeated measures analysis of variance was applied followed by Tukey-Kramer multiple for comparisons between treatments. All analyzes were performed using SAS software (release 9.1, 2003, SAS Institute Inc., Cary, USA) (p ? 0.05). MP greatly improved after IRPD and IFPD use with an increase of 85% and 87% respectively. Similar results were observed in respect to FCI and MBF with an increase (p ? 0.0001) of 91% and 62% in FCI and of 79% and 62% in MBF after the IRPD and IFPD use, respectively. Regardless the prosthesis type, the use of IRPD and IFPD increased the masseter thickness during maximum voluntary clenching (p ? 0.0001) and altered the chewing movements, reducing the total cycle time, as well as the duration of opening and closing phases (p ? 0.05). MA improved after IRPD and IFPD use, irrespectively of the food rated. ST was affected by prosthetic treatment, showing a reduction in the number of chewing cycles and in the size of the comminuted particle, with the lowest values observed after IFPD use. There was a raise in fiber (p = 0.007), calcium (p = 0.001) and iron (p = 0.02) intake after the IFPD use and a reduction in the intake of food with high cholesterol levels (p = 0.02). Patients satisfaction also increased (p ? 0.05) and the impact of oral health on QOL decreased in overall score (p = 0.04) and in the physical pain domain (p = 0.02) after the IFPD use. The rehabilitation of partially edentulous patients with IRPD and IFPD significantly improved masticatory function and the magnitude of the effect was related to the prosthesis type / Doutorado / Protese Dental / Doutora em Clínica Odontológica
9

Influência do orifício de acesso ao parafuso do intermediário do implante na resistência de infraestruturas de zircônia estabilizadas por ítrio e dissilicato de lítio / Influence the access hole to screw the implant in the intermediate resitance of infrastructure zirconia stabilized by yttrium and lithium disilicate

William Bogard de Souza e Silva 01 June 2014 (has links)
Hipótese do trabalho: Avaliar a presença de um orifício de acesso ao parafuso do intermediário do implante em infra-estruturas cimentadas sobre o pilar de titânio. Objetivo: O presente estudo visou comparar resistência a compressão de infra-estruturas em zircônia estabilizada por ítrio e em dissilicato de lítio cimentadas sobre pilar em titânio, com e sem acesso ao parafuso. Método: Foram confeccionados quarenta corpos-de-prova compostos por análogos de implantes hexágono externo de plataforma 4,1mm, intermediários de titânio pré-fabricado para próteses cimentadas e infra-estruturas para coroas totais. Os corpos-de-prova foram divididos em quatro grupos experimentais, sendo vinte, em cerâmica de zircônia estabilizada por ítrio(G1 e G2) e vinte em cerâmica de dissilicato de lítio(G3 e G4), todas confeccionadas com a mesma anatomia, ambas para próteses cimentadas sobre implante. Das vinte infra-estruturas de cada tipo de cerâmica, dez foram infra-estruturas convencionais para coroas cimentadas, constituindo o grupo controle e dez apresentavam um orifício de acesso ao parafuso, transpassando a cerâmica, constituindo o grupo experimental. As cimentações foram efetuadas com agente de fixação RelyX U200, de acordo com as especificações do fabricante, e o grupo experimental (com acesso ao parafuso) teve o orifício de acesso ao canal restaurado com resina composta foto ativada Z350 Filtek Supreme XT. Os corpos-de-prova foram submetidos a teste de compressão com velocidade de 0,5mm/minuto em máquina de ensaio universal. Resultados: Não foram encontradas diferenças estatísticas significativas entre infra-estruturas de cerâmicas convencionais e as infra-estruturas confeccionadas com orifício de acesso oclusal(G2 1.675 N/cm., G3 1.931 N/cm e G4 1.447 N/cm), exceto as infra-estruturas convencionais de zircônia estabilizada por ítrio que se apresentou superior aos demais(G1 3.372 N/cm). Com base nos resultados todas as modalidades de infra-estruturas testadas são viáveis para o uso clínico. / Hypothesis of work: To evaluate the presence of an access hole to screw the intermediate cemented implant in infrastructure over the titanium abutment. Objective: This study aimed to compare the compressive strength of infrastructure in yttrium stabilized zirconia and lithium disilicate cemented to abutment in titanium, with and without access to the screw. Method: Forty bodies-specimens consisting of similar external hex implants platform 4.1mm, intermediate titanium prefabricated for cemented prostheses and infrastructures for crowns were fabricated. The bodies-specimens were divided into four experimental groups, twenty, ceramic yttrium stabilized zirconia (G1 and G2) and twenty in ceramic lithium disilicate (G3 and G4), all made with the same anatomy, both for cemented prostheses on implants. Infrastructure of twenty of each type of tile ten were conventional infrastructure for cemented crowns, constituting the control group and ten had an access hole to the screw, trespassing ceramics, constituting the experimental group. The cementation were performed with RelyX U200 fixing agent, according to the manufacturers specifications, and the experimental group (with access to the screw) had the access hole channel restored with composite resin Z350 photo activated Filtek Supreme XT. The bodies-specimens were subjected to compression test speed of 0.5 mm / min in a universal testing machine. Results: No statistically significant differences between conventional ceramic infrastructure and infrastructure made with port access were found occlusal (G2 1675 N / cm, G3 1931 N / cm and G4 1447 N / cm.) Except conventional infrastructure stabilized zirconia yttrium who introduced himself superior to the others (G1 3300 N / cm). Based on the results of all modalities tested infrastructure are feasible for clinical use.

Page generated in 0.0951 seconds