• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 64
  • 64
  • 64
  • 31
  • 25
  • 21
  • 18
  • 18
  • 18
  • 16
  • 15
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas /

Delben, Juliana Aparecida. January 2009 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Ivete Aparecida de Mattias Sartori / Resumo: A longevidade das próteses e implantes é dependente da adequada adaptação entre os componentes bem como da distribuição favorável de forças às estruturas de suporte. O afrouxamento do parafuso de retenção é uma falha mecânica comumente observada devido à redução da pré-carga gerada no parafuso de retenção, responsável pela manutenção da estabilidade da união parafusada e resistência às forças que tendem a separar os componentes. O objetivo do estudo foi avaliar a influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas, submetidos a sucessivos reapertos e ciclagem mecânica. Foram confeccionadas 60 coroas de acordo com os grupos de estudo (n=12): Grupo I - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metalocerâmicas, Grupo II - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metaloplásticas, Grupo III - pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metalocerâmicas, Grupo IV - pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metaloplásticas, Grupo IV - pilares de zircônia obtidos pelo sistema CAD/CAM (computer-aided design/computer-aided manufacturing) para obtenção de coroas cerâmicas. As coroas foram unidas a implantes de hexágono externo por meio de parafuso de retenção quadrado de ouro com torque de inserção de 35 Ncm e submetidas à ciclagem mecânica com aplicação de carregamento vertical dinâmico de 50N a uma freqüência de 2Hz. Valores de destorque foram mensurados antes da ciclagem mecânica e após cada período de 1x105 ciclos seguido de reaperto com 35 Ncm de modo a completar 1x106 ciclos. Mensurações da desadaptação vertical na interface pilar-implante foram realizadas através de estereomicroscopia inicialmente e ao final da... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The longevity of prostheses and implants depends on fit betweenn components as well as adequate forces distribution to supporting structures. Retaining screw loosening is a commom mechanical complication due to preload reduction that provides joint stability and resistance to separating forces. The aim of this study was to evaluate the influence of different abutments and veneering materials on preload maintenance of retaining screw of implant-supported crowns submitted to repeated tightening and mechanical cycling. Sixty crowns were obtained according to the groups (n=12): Group I - Gold UCLA abutment cast in gold allow with ceramic vennering, Group II - Gold UCLA abutment cast in gold alloy with resin veneering, Group III - UCLA abutment cast in titanium with ceramic veneering, Group IV - UCLA abutment cast in titanium with resin veneering, and Group V - zirconia abutment obtained by CAD/CAM (computer-aided desing/computer-aided manufacturing) system with ceramic veneering. The crowns were attached to external hexagon implants by gold retaining screws with insertion torque of 35Ncm. The replicas were submitted to mechanical cycling with vertical dinamic loading of 50N at 2Hz. Detorque measurements were performed initially and after each period of 1x105 cycles followed by retightening of retaining screw with 35Ncm until 1x106 cycles. Measurements of vertical misfit on abutment-implant interface were performed through estereomicroscopy initially and after mechanical cycling. Data were submitted to analysis of variance, Fisher's exact test, paired t test, Student's t-test and Pearson correlation (P<.05). All detorque measurements were lower than insertion torque of 35Ncm. There was statistically significant difference among the 5 groups (P<.05) for detorque values obtained initially and after mechanical cycling. However, there was no statistically significant difference... (Complete abstract click electronic access below) / Mestre
42

Avaliação do processo de reparo periimplantar utilizando matriz óssea heterógena desmineralizada ou osso autógeno : análise histológica e histométrica em tíbias de coelhos /

Salim, Martha Alayde Alcantara. January 2009 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Paulo Sérgio Perri de Carvalho / Banca: José Renato Costa / Banca: Roberto Prado / Banca: Sergio Luiz Melo Gonçalves / Resumo: Este estudo teve como objetivo avaliar o reparo ósseo em defeitos periimplatares experimentais utilizando enxerto autógeno e implante de matriz óssea bovina desmineralizada em tíbias de coelhos. Foram instalados 30 implantes de titânio diâmetro de 3,75 mm plataforma regular (4,1 mm) e altura de 10 mm, no qual cada animal recebeu dois implantes na face lateral da porção mediana da tíbia. Ao redor dos implantes foi confeccionado defeito ósseo de 6,0 mm de diâmetro através da trefina e enxertado no local osso autógeno ou matriz óssea heterógena desmineralizada. As lâminas obtidas foram submetidas à análise histológica e histométrica com contagem das áreas de osso neoformado, matriz óssea bovina, medula e enxerto de osso autógeno. Como resultado observou-se diferença significativa entre a formação de novo osso no período de 15 dias quando comparado o grupo de implante de matriz óssea bovina desmineralizada e enxerto autógeno, demonstrando maior formação óssea neste último; e diferença significativa entre a permanência do tecido implantado em relação ao enxerto autógeno, demonstrado pela permanência da matriz no período de 60 dias. Avaliando os dados obtidos nesta pesquisa concluímos que o processo de reparo periimplantar ocorreu com maior neoformação óssea no grupo tratado por enxerto de osso autógeno e a matriz óssea bovina desmineralizada se comportou como um condutor ósseo de lenta absorção sem demonstrar reação inflamatória aguda ou crônica. / Abstract: This study aimed to evaluate the bone healing in experimental periimplatar defects using autogenous graft and implantation of bovine demineralized bone matrix in the tibia of rabbits. Were installed 30 titanium implants of 3.75 mm diameter regular platform (4.1 mm) and height of 10 mm, in which each animal received two implants in the median portion of the tibial. Around the implants was made bone defect of 6.0 mm in diameter through the trephine and grafted in place autogenous bone or demineralized bone matrix heterogenous. The slides obtained were subjected to histological and histometric count with areas of newly formed bone, bovine bone matrix, bone marrow and bone graft. Results revealed a significant difference between the formation of new bone within 15 days when compared to the group of implant bovine demineralized bone matrix and autogenous graft, showing a higher bone formation in the latter, and a significant difference between the permanence of the implanted tissue in compared to autograft, demonstrated by the permanence of the matrix within 60 days. Evaluating the data obtained in this study concluded that the repair process was better in periimplant bone formation than in the group treated with autogenous bone graft and demineralized bovine bone matrix acted as a conductor low absorption without showing acute inflammatory reaction or chronic. / Doutor
43

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes : fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem) /

Costa, Elza Maria Valadares da. January 2001 (has links)
Orientador: Maximiliano Piero Neisser / Banca: Mauro Antonio de Arruda Nóbilo / Banca: Marco Antonio Bottino / Resumo : Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Abstract: Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with "chromium steel", five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.) / Mestre
44

Análise da influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna das tensões, através do método de elementos finitos bidimensional

Barão, Valentim Adelino Ricardo [UNESP] 18 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-18Bitstream added on 2014-06-13T20:18:40Z : No. of bitstreams: 1 barao_var_me_araca.pdf: 2925422 bytes, checksum: 91ac65727dd1aa72a0e59c81f8a2faa1 (MD5) / Os implantes osseointegrados quando submetidos a cargas funcionais transmitem as tensões geradas diretamente ao osso. Dessa forma, muitas falhas na osseointegração estão ligadas ao excesso de carga sobre o implante. No caso de próteses implanto-retidas e muco-suportadas, outro importante fator que pode contribuir para uma maior ou menor incidência de tensões ao nível do implante reside na diferença de resiliência entre a fibromucosa e o implante. No tratamento com overdentures, este mecanismo de transmissão e distribuição não está bem documentado. Dessa forma, o objetivo desse estudo foi analisar, através do Método de Elementos Finitos bidimensional, a influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna de tensões. Foram construídos em computador, através do programa Auto CAD, modelos matemáticos representativos de cortes frontais da mandíbula, sendo modelo A (controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula suporte de overdenture com dois attachments esféricos do tipo o’ring em dois implantes independentes e modelo D, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico associados a dois attachments esféricos distais do tipo o’ring. Em todos os modelos, a fibromucosa assumiu três características de espessura (1, 3 e 5mm) nas resiliências dura, resiliente e flácida, respectivamente, através da variação do módulo de elasticidade da fibromucosa. Para análise, simulada no programa Ansys, os modelos foram fixados nas laterais direita e esquerda, permitindo deflexão da mandíbula. Foi aplicada... / Implants overload is the main factor responsible for osseointegration loss since functional loads are distributed directly to the bone. In addition, the difference between mucosa and implant mobility influence stress level, mainly in prosthesis supported by implant and mucosa. In overdenture treatments, the mechanisms of stress transmission and distribution induced by attachments system are not completely understood as literature concerning the influence of several biomechanical factors remains inconclusive. Thus, the aim of this study was to evaluate the effect of different mucosa thickness and resilience on stress distribution of implant-retained overdentures with different attachment systems using a two-dimensional Finite Element Analysis (FEA-2D). Representative models of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system; Group C, a model of edentulous mandible supporting an overdenture retained by two unsplinted implants with o’ring system; Group D, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system associated with two distally o’ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5mm) in the resiliences hard, resilient and soft, respectively, through different mucosa’s Young modulus. Evaluation was performed on Ansys software, with both right and left sides of models fasttened to allow mandibular bending. A vertical load of 100N was applied on lower central incisive teeth, and the principal stress was used as analysis criteria. Overall, group A showed the lowest stress values followed by groups C, D and B both in general stress maps as in the evaluation of... (Complete abstract click electronic access below)
45

Análise microbiológica da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados: estudo em cães /

Shibli, Jamil Awad. January 2000 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Izabel Yoko Ito / Banca: Roberto Fraga Moreira Lotufo / Resumo: A microbiota presente na peri-implantite induzida por ligadura, em diferentes superfícies de implantes osseointegrados, foi analisada em 6 cães adultos machos. 36 implantes osseointegrados (9 Ticp: titânio comercialmente puro; 9 TPS: titânio plasma spray; 9 HA: hidroxiapatita; 9 superfícies tratadas com ácidos) foram inseridos e distribuídos igualmente 3 meses após exodontia de todos os pré-molares inferiores. Após um período de 3 meses de osseointegração, os implantes receberam os cicatrizadores. Decorridos 45 dias de cicatrização, amostras peri-implantares foram colhida, utilizando pontas de papel, no período 0 e após a colocação de ligaduras com fio de algodão, nos períodos 20, 40 e 60 dias. A contagem total de microrganismos (CTM) e a proporação de A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermedia, Campylobacter sp, Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, bastonetes anaeróbios Gram-negativos, Streptococcus beta-hemolíticos, Eikenella corrodens e Candida sp. foram analisadas. Não houve diferença da CTM entre as diferentes superfícies (p>0,05). A Pg não foi detectada no tempo 0; nos tempos 20 e 40 foi detectada em 12 implantes (4 Ticp, 4 HA, 2 TPS e 1 Sup. Trat. com ácidos) e no período 60 dias, em 9 (2 Ticp, 3 HA, 2 TPS e 1 Sup. Trat. com ácidos), tendo menor afinidade à superfície tratada com ácidos. Pi foi detectada em 5 implantes (2 Ticp, 2 HA e 1 Sup. Trat. com ácidos) no período 0 e em 100% dos implantes nos demais períodos. Fusobacterium sp. foi detectado em todos os períodos, tendo uma maior afinidade à HA. Streptococcus beta-hemolíticos foi detectado em 6 implantes (3 Ticp, 1 TPS e 2 HA) no período 0 e 30, 26 e 24 implantes respectivamente nos períodos 20, 40 e 60. Campylobacter sp. e Candida sp. foram detectadas em baixas proporções. Os demais microrganismos não... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The microbiota associated with ligature-induced peri-implantitis, in different dental implants surfaces, was investigated by cultivation on enriched non-selective and various selective solid media, in 6 mongrel dogs. 36 dental implants (9 Ticp: titanium commercially pure; 9 TPS: titanium plasma spray; 9 HA: hidroxiapatite; 9 surfaces acid-etched) were placed in a similar distribution in all dogs 3 months after extraction of all premolars in mandible. Following a healing period of 3 months, healing abutments were installed and 45 days after cotton ligatures were placed and oral-cleaning procedures abolished for 2 months to induce vertical bone loss of about 40%. Microbial samples were with paper points on day of ligature placement and after 20, 40 and 60 days. The total number of cultivable bacteria and proportions of A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermediate, Campylobacter sp., Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, Enteric Gram-negative rods, beta-hemolytic Streptococcus, Eikenella corrodens and Candida sp. were analyzed. No significant microbiological differences were observed among the different surfaces (p>0,05). Pg was not detected in the time 0; already in the times 20 and 40 were detected in 12 dental implants (4 Ticp, 4 HA, 2 TPS and 1 acid-etched surface) and in the period 60 days, in 9(2 Ticp, 3 HA, 2 TPS and 1 acid-etched surface), tends smaller affinity to eh surface with acids-etched surface. Pi was detected in 5 implants (2 Ticp, 2 HA and 1 acid-etched surface) in the period 0 and in 100% of implants in other periods. Fusobacterium sp. was detected in all the periods, tends a larger affinity to HA. Beta-hemolytic Streptococcus was detected in 6 implants (3 Ticp, 1 TPS and 2 HA) in the period 0 and 30, 26 and 24... (Complete abstract, click electronic address below). / Mestre
46

Avaliação da osseointegração promovida por implantes jateados por Al2O3 : análises histológica e histométrica em cães /

Ponzoni, Daniela. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Resumo: A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / Abstract: An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias. / Doutor
47

Avaliação clínica e radiográfica de implantes osseointegráveis instalados na mandíbula posterior e submetidos a um protocolo de função oclusal precoce /

Pinto, Antonio Vicente de Souza. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Resumo: As vantagens do tratamento do edentulismo total mandibular com implantes osseointegráveis e função oclusal precoce são bem conhecidas. Recentemente, um interesse crescente pelos benefícios dessa modalidade terapêutica envolveu o edentulismo parcial em várias regiões da boca. No entanto, protocolos bem definidos para a mandíbula posterior com função oclusal precoce não foram devidamente testados e aprovados. O objetivo desta investigação foi avaliar a eficácia clínica de um protocolo cirúrgico, protético e radiográfico para o tratamento da mandíbula posterior, com implantes osseointegráveis e função oclusal precoce. Treze pacientes com edentulismo parcial posterior, uni ou bilateral, foram tratados em clínica particular. Cinqüenta e dois implantes foram inseridos em 17 áreas mandibulares, com classes I, II e III de Kennedy. Os implantes utilizados foram MKIII e MKIV, com superfície lisa e foi empregada técnica cirúrgica padronizada para inserção dos implantes. A função oclusal precoce foi obtida com próteses parciais fixas instaladas com uma média de 7 dias da inserção dos implantes.O tempo de observação clínica variou entre 12 e 26 meses, com média de 19 meses. O nível do osso marginal foi determinado com medidas nas imagens digitalizadas de radiografias convencionais padronizadas. A taxa cumulativa de sobrevivência foi de 98,1% e a perda óssea marginal média, nos primeiros seis meses, foi de 1,02mm e 1,07mm para um ano de observação. A taxa da sobrevivência das próteses foi de 100%. Considerando os limites deste estudo, o protocolo testado para tratamento da mandíbula posterior com função oclusal precoce e implantes osseointegráveis parece viável para aplicação clínica em bases rotineiras, No entanto, estudos multicêntricos e a longo prazo devem ser conduzidos para confirmar ou refutar os resultados obtidos. / Abstract: The early occlusal loading of Osseointegrated implants in mandibular totally edentulous patients have been shown to be a successful and an advantageous approach. Recently, this treatment modality evolved to the treatment of partially edentulous patients. However protocols for treating those cases were neither tested nor approved. The objective of this investigation was to evaluate the clinical efficacy of a surgical, a prosthetic and a radiographic protocol idealized for the treatment of the posterior mandible with early occlusaly loaded osseointegrated implants. Thirteen partially edentulous patients in the posterior mandibleunilaterally or bilaterally, were treated in a private practice setting. Fifty two fixtures were placed in seventeen mandibular areas class I, II and III accordingly to Kennedy's classification. Machined MKIII and MKIV implants were placed utilizing standardized surgical technique. Early loading conditions were obtained with the placement of fixed partial dentures installed in average seven days after fixtures installation. The clinical observation time varied between 12 and 26 months with an average of 19 months. The marginal bone levels were determined from digital images derived from standardized conventional radiographs. A mean marginal bone loss of 1.02mm was noted in the first six months of observation and a mean marginal bone loss of 1.07 mm after 12 months under the evaluated conditions. The cumulative survival rate of 98.1% and 100 % were found for implants and prostheses respectively. Within the limits of this study, it can be concluded that the tested protocol for the treatment of the posterior mandible with osseointegrated implants under early occlusal loading condition seemed to be a viable clinical alternative for routine application. Nevertheless, additional studies including a multicenter design and longer evaluation periods are necessary to substantiate these findings. / Doutor
48

Avaliação do processo de reparo periimplantar utilizando matriz óssea heterógena desmineralizada ou osso autógeno: análise histológica e histométrica em tíbias de coelhos

Salim, Martha Alayde Alcantara [UNESP] 27 November 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-11-27Bitstream added on 2014-06-13T21:02:12Z : No. of bitstreams: 1 salim_maa_dr_araca.pdf: 2801897 bytes, checksum: 99b625311eab55330261435209d48950 (MD5) / Este estudo teve como objetivo avaliar o reparo ósseo em defeitos periimplatares experimentais utilizando enxerto autógeno e implante de matriz óssea bovina desmineralizada em tíbias de coelhos. Foram instalados 30 implantes de titânio diâmetro de 3,75 mm plataforma regular (4,1 mm) e altura de 10 mm, no qual cada animal recebeu dois implantes na face lateral da porção mediana da tíbia. Ao redor dos implantes foi confeccionado defeito ósseo de 6,0 mm de diâmetro através da trefina e enxertado no local osso autógeno ou matriz óssea heterógena desmineralizada. As lâminas obtidas foram submetidas à análise histológica e histométrica com contagem das áreas de osso neoformado, matriz óssea bovina, medula e enxerto de osso autógeno. Como resultado observou-se diferença significativa entre a formação de novo osso no período de 15 dias quando comparado o grupo de implante de matriz óssea bovina desmineralizada e enxerto autógeno, demonstrando maior formação óssea neste último; e diferença significativa entre a permanência do tecido implantado em relação ao enxerto autógeno, demonstrado pela permanência da matriz no período de 60 dias. Avaliando os dados obtidos nesta pesquisa concluímos que o processo de reparo periimplantar ocorreu com maior neoformação óssea no grupo tratado por enxerto de osso autógeno e a matriz óssea bovina desmineralizada se comportou como um condutor ósseo de lenta absorção sem demonstrar reação inflamatória aguda ou crônica. / This study aimed to evaluate the bone healing in experimental periimplatar defects using autogenous graft and implantation of bovine demineralized bone matrix in the tibia of rabbits. Were installed 30 titanium implants of 3.75 mm diameter regular platform (4.1 mm) and height of 10 mm, in which each animal received two implants in the median portion of the tibial. Around the implants was made bone defect of 6.0 mm in diameter through the trephine and grafted in place autogenous bone or demineralized bone matrix heterogenous. The slides obtained were subjected to histological and histometric count with areas of newly formed bone, bovine bone matrix, bone marrow and bone graft. Results revealed a significant difference between the formation of new bone within 15 days when compared to the group of implant bovine demineralized bone matrix and autogenous graft, showing a higher bone formation in the latter, and a significant difference between the permanence of the implanted tissue in compared to autograft, demonstrated by the permanence of the matrix within 60 days. Evaluating the data obtained in this study concluded that the repair process was better in periimplant bone formation than in the group treated with autogenous bone graft and demineralized bovine bone matrix acted as a conductor low absorption without showing acute inflammatory reaction or chronic.
49

Avaliação clínica e radiográfica de implantes osseointegráveis instalados na mandíbula posterior e submetidos a um protocolo de função oclusal precoce

Pinto, Antonio Vicente de Souza [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:43:56Z : No. of bitstreams: 1 pinto_avs_dr_araca.pdf: 1496770 bytes, checksum: c9fd8c4da9c28379a95d5da49951a5df (MD5) / 3i Implant / As vantagens do tratamento do edentulismo total mandibular com implantes osseointegráveis e função oclusal precoce são bem conhecidas. Recentemente, um interesse crescente pelos benefícios dessa modalidade terapêutica envolveu o edentulismo parcial em várias regiões da boca. No entanto, protocolos bem definidos para a mandíbula posterior com função oclusal precoce não foram devidamente testados e aprovados. O objetivo desta investigação foi avaliar a eficácia clínica de um protocolo cirúrgico, protético e radiográfico para o tratamento da mandíbula posterior, com implantes osseointegráveis e função oclusal precoce. Treze pacientes com edentulismo parcial posterior, uni ou bilateral, foram tratados em clínica particular. Cinqüenta e dois implantes foram inseridos em 17 áreas mandibulares, com classes I, II e III de Kennedy. Os implantes utilizados foram MKIII e MKIV, com superfície lisa e foi empregada técnica cirúrgica padronizada para inserção dos implantes. A função oclusal precoce foi obtida com próteses parciais fixas instaladas com uma média de 7 dias da inserção dos implantes.O tempo de observação clínica variou entre 12 e 26 meses, com média de 19 meses. O nível do osso marginal foi determinado com medidas nas imagens digitalizadas de radiografias convencionais padronizadas. A taxa cumulativa de sobrevivência foi de 98,1% e a perda óssea marginal média, nos primeiros seis meses, foi de 1,02mm e 1,07mm para um ano de observação. A taxa da sobrevivência das próteses foi de 100%. Considerando os limites deste estudo, o protocolo testado para tratamento da mandíbula posterior com função oclusal precoce e implantes osseointegráveis parece viável para aplicação clínica em bases rotineiras, No entanto, estudos multicêntricos e a longo prazo devem ser conduzidos para confirmar ou refutar os resultados obtidos. / The early occlusal loading of Osseointegrated implants in mandibular totally edentulous patients have been shown to be a successful and an advantageous approach. Recently, this treatment modality evolved to the treatment of partially edentulous patients. However protocols for treating those cases were neither tested nor approved. The objective of this investigation was to evaluate the clinical efficacy of a surgical, a prosthetic and a radiographic protocol idealized for the treatment of the posterior mandible with early occlusaly loaded osseointegrated implants. Thirteen partially edentulous patients in the posterior mandibleunilaterally or bilaterally, were treated in a private practice setting. Fifty two fixtures were placed in seventeen mandibular areas class I, II and III accordingly to Kennedy’s classification. Machined MKIII and MKIV implants were placed utilizing standardized surgical technique. Early loading conditions were obtained with the placement of fixed partial dentures installed in average seven days after fixtures installation. The clinical observation time varied between 12 and 26 months with an average of 19 months. The marginal bone levels were determined from digital images derived from standardized conventional radiographs. A mean marginal bone loss of 1.02mm was noted in the first six months of observation and a mean marginal bone loss of 1.07 mm after 12 months under the evaluated conditions. The cumulative survival rate of 98.1% and 100 % were found for implants and prostheses respectively. Within the limits of this study, it can be concluded that the tested protocol for the treatment of the posterior mandible with osseointegrated implants under early occlusal loading condition seemed to be a viable clinical alternative for routine application. Nevertheless, additional studies including a multicenter design and longer evaluation periods are necessary to substantiate these findings.
50

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos /

Tabata, Lucas Fernando. January 2005 (has links)
Resumo: No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / Abstract: on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antônio Capello Sousa / Banca: Eduardo Passos Rocha / Banca: Ricardo Faria Ribeiro / Banca: Wirley Gonçalves Assunção / Mestre

Page generated in 0.1354 seconds