• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 3
  • Tagged with
  • 12
  • 12
  • 7
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A study of two methods for cementing pin-retained prostheses with zinc phosphate cement

Young, Jerry Lee. January 1979 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1979. / Typescript (photocopy). Includes bibliographical references (leaves 53-64). Also issued in print.
2

A study of two methods for cementing pin-retained prostheses with zinc phosphate cement

Young, Jerry Lee. January 1979 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1979. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 53-64).
3

The effect of cementation technique on the retention of adhesively cemented prefabricated posts

Polo Montes, Carlos A. January 2007 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2007. / Title from first page of PDF file (viewed Feb. 5, 2008). Includes bibliographical references (p. 71-83).
4

"Avaliação da retenção de prótese total bimaxilar em função das características da área basal" / Evaluation of the retention of bimaxillay complete denture in function of the characteristics of the basal area.

Cunha, Eudes Francisco da Silva 28 January 2005 (has links)
Nesta pesquisa, em 14 pacientes da Clínica de Prótese Total da Faculdade de Odontologia da Universidade de São Paulo, foi realizada a avaliação da retenção de prótese total bimaxilar em função das características da área basal por três avaliadores clínicos experientes e calibrados. Foram avaliadas as retenções vertical anterior, laterais direita e esquerda e póstero-anterior e as características da área basal: forma, tamanho, altura e tipo do rebordo e a consistência da fibromucosa. Por se tratarem de opiniões, os dados foram transformados em escores e submetidos à análise de variância não paramétrica com o teste KRUSKAL-WALLIS e paramétrica com o teste ANOVA. Concluiu-se que, na maxila, a retenção das próteses totais novas foi influenciada positivamente pelo tipo rebordo paralelo e pela consistência resiliente da fibromucosa, enquanto na mandíbula influenciaram o tamanho médio e a forma oval. As opiniões sobre a retenção e o grau de satisfação entre os avaliadores e os pacientes foram as mesmas. / In this research, a evaluation of the retention of bimaxilar complete denture in function of the characteristics of the basal area by three calibrated experienced clinician was accomplished in 14 patients of the Odontology College of the University of São Paulo. The anterior vertical retention, right lateral retention, left lateral retention, posteroanterior retention and rigde shape, ridge size, rigde height, ridge type and the fibromucosa consistency were evaluated. Because of they are opinions, the data were trans formed in scores and submitted to the no parametric variance analysis with the KRUSKAL-WALLIS and ANOVA parametric tests. Conclusion, in the maxilla, the retention of the new complete denture, was positively influenced by the parallel rigde type and by the resilient consistency of the fibromucosa, while in the mandible, the decisive factors of the retention were the medium size of the rigde and the oval shape of this. The opinions about the retention and the level of satisfaction had been the same among the appraisers and patients.
5

Análise da influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna das tensões, através do método de elementos finitos bidimensional /

Barão, Valentim Adelino Ricardo. January 2008 (has links)
Resumo: Os implantes osseointegrados quando submetidos a cargas funcionais transmitem as tensões geradas diretamente ao osso. Dessa forma, muitas falhas na osseointegração estão ligadas ao excesso de carga sobre o implante. No caso de próteses implanto-retidas e muco-suportadas, outro importante fator que pode contribuir para uma maior ou menor incidência de tensões ao nível do implante reside na diferença de resiliência entre a fibromucosa e o implante. No tratamento com overdentures, este mecanismo de transmissão e distribuição não está bem documentado. Dessa forma, o objetivo desse estudo foi analisar, através do Método de Elementos Finitos bidimensional, a influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna de tensões. Foram construídos em computador, através do programa Auto CAD, modelos matemáticos representativos de cortes frontais da mandíbula, sendo modelo A (controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula suporte de overdenture com dois attachments esféricos do tipo o'ring em dois implantes independentes e modelo D, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico associados a dois attachments esféricos distais do tipo o'ring. Em todos os modelos, a fibromucosa assumiu três características de espessura (1, 3 e 5mm) nas resiliências dura, resiliente e flácida, respectivamente, através da variação do módulo de elasticidade da fibromucosa. Para análise, simulada no programa Ansys, os modelos foram fixados nas laterais direita e esquerda, permitindo deflexão da mandíbula. Foi aplicada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Implants overload is the main factor responsible for osseointegration loss since functional loads are distributed directly to the bone. In addition, the difference between mucosa and implant mobility influence stress level, mainly in prosthesis supported by implant and mucosa. In overdenture treatments, the mechanisms of stress transmission and distribution induced by attachments system are not completely understood as literature concerning the influence of several biomechanical factors remains inconclusive. Thus, the aim of this study was to evaluate the effect of different mucosa thickness and resilience on stress distribution of implant-retained overdentures with different attachment systems using a two-dimensional Finite Element Analysis (FEA-2D). Representative models of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system; Group C, a model of edentulous mandible supporting an overdenture retained by two unsplinted implants with o'ring system; Group D, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system associated with two distally o'ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5mm) in the resiliences hard, resilient and soft, respectively, through different mucosa's Young modulus. Evaluation was performed on Ansys software, with both right and left sides of models fasttened to allow mandibular bending. A vertical load of 100N was applied on lower central incisive teeth, and the principal stress was used as analysis criteria. Overall, group A showed the lowest stress values followed by groups C, D and B both in general stress maps as in the evaluation of... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antonio Capello de Sousa / Banca: Eduardo Passos Rocha / Banca: João Neudenir Arioli Filho / Mestre
6

"Avaliação da retenção de prótese total bimaxilar em função das características da área basal" / Evaluation of the retention of bimaxillay complete denture in function of the characteristics of the basal area.

Eudes Francisco da Silva Cunha 28 January 2005 (has links)
Nesta pesquisa, em 14 pacientes da Clínica de Prótese Total da Faculdade de Odontologia da Universidade de São Paulo, foi realizada a avaliação da retenção de prótese total bimaxilar em função das características da área basal por três avaliadores clínicos experientes e calibrados. Foram avaliadas as retenções vertical anterior, laterais direita e esquerda e póstero-anterior e as características da área basal: forma, tamanho, altura e tipo do rebordo e a consistência da fibromucosa. Por se tratarem de opiniões, os dados foram transformados em escores e submetidos à análise de variância não paramétrica com o teste KRUSKAL-WALLIS e paramétrica com o teste ANOVA. Concluiu-se que, na maxila, a retenção das próteses totais novas foi influenciada positivamente pelo tipo rebordo paralelo e pela consistência resiliente da fibromucosa, enquanto na mandíbula influenciaram o tamanho médio e a forma oval. As opiniões sobre a retenção e o grau de satisfação entre os avaliadores e os pacientes foram as mesmas. / In this research, a evaluation of the retention of bimaxilar complete denture in function of the characteristics of the basal area by three calibrated experienced clinician was accomplished in 14 patients of the Odontology College of the University of São Paulo. The anterior vertical retention, right lateral retention, left lateral retention, posteroanterior retention and rigde shape, ridge size, rigde height, ridge type and the fibromucosa consistency were evaluated. Because of they are opinions, the data were trans formed in scores and submitted to the no parametric variance analysis with the KRUSKAL-WALLIS and ANOVA parametric tests. Conclusion, in the maxilla, the retention of the new complete denture, was positively influenced by the parallel rigde type and by the resilient consistency of the fibromucosa, while in the mandible, the decisive factors of the retention were the medium size of the rigde and the oval shape of this. The opinions about the retention and the level of satisfaction had been the same among the appraisers and patients.
7

Análise da influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna das tensões, através do método de elementos finitos bidimensional

Barão, Valentim Adelino Ricardo [UNESP] 18 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-18Bitstream added on 2014-06-13T20:18:40Z : No. of bitstreams: 1 barao_var_me_araca.pdf: 2925422 bytes, checksum: 91ac65727dd1aa72a0e59c81f8a2faa1 (MD5) / Os implantes osseointegrados quando submetidos a cargas funcionais transmitem as tensões geradas diretamente ao osso. Dessa forma, muitas falhas na osseointegração estão ligadas ao excesso de carga sobre o implante. No caso de próteses implanto-retidas e muco-suportadas, outro importante fator que pode contribuir para uma maior ou menor incidência de tensões ao nível do implante reside na diferença de resiliência entre a fibromucosa e o implante. No tratamento com overdentures, este mecanismo de transmissão e distribuição não está bem documentado. Dessa forma, o objetivo desse estudo foi analisar, através do Método de Elementos Finitos bidimensional, a influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna de tensões. Foram construídos em computador, através do programa Auto CAD, modelos matemáticos representativos de cortes frontais da mandíbula, sendo modelo A (controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula suporte de overdenture com dois attachments esféricos do tipo o’ring em dois implantes independentes e modelo D, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico associados a dois attachments esféricos distais do tipo o’ring. Em todos os modelos, a fibromucosa assumiu três características de espessura (1, 3 e 5mm) nas resiliências dura, resiliente e flácida, respectivamente, através da variação do módulo de elasticidade da fibromucosa. Para análise, simulada no programa Ansys, os modelos foram fixados nas laterais direita e esquerda, permitindo deflexão da mandíbula. Foi aplicada... / Implants overload is the main factor responsible for osseointegration loss since functional loads are distributed directly to the bone. In addition, the difference between mucosa and implant mobility influence stress level, mainly in prosthesis supported by implant and mucosa. In overdenture treatments, the mechanisms of stress transmission and distribution induced by attachments system are not completely understood as literature concerning the influence of several biomechanical factors remains inconclusive. Thus, the aim of this study was to evaluate the effect of different mucosa thickness and resilience on stress distribution of implant-retained overdentures with different attachment systems using a two-dimensional Finite Element Analysis (FEA-2D). Representative models of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system; Group C, a model of edentulous mandible supporting an overdenture retained by two unsplinted implants with o’ring system; Group D, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system associated with two distally o’ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5mm) in the resiliences hard, resilient and soft, respectively, through different mucosa’s Young modulus. Evaluation was performed on Ansys software, with both right and left sides of models fasttened to allow mandibular bending. A vertical load of 100N was applied on lower central incisive teeth, and the principal stress was used as analysis criteria. Overall, group A showed the lowest stress values followed by groups C, D and B both in general stress maps as in the evaluation of... (Complete abstract click electronic access below)
8

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos /

Tabata, Lucas Fernando. January 2005 (has links)
Resumo: No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / Abstract: on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antônio Capello Sousa / Banca: Eduardo Passos Rocha / Banca: Ricardo Faria Ribeiro / Banca: Wirley Gonçalves Assunção / Mestre
9

Desenvolvimento de dois modelos de mini-implantes e componentes protéticos: correlação da macroestrutura e propriedades mecânicas / Development of two models of mini-implants and prosthetic components: macrostructure correlation and mechanical properties

Valente, Mariana Lima da Costa 19 January 2018 (has links)
O edentulismo acomete grande parcela da população mundial, especialmente os idosos, gerando perda da função mastigatória, desordens nutricionais, estética desfavorável e redução da qualidade de vida. Como alternativa a esses problemas, as overdentures implanto retidas tem representado uma modalidade de tratamento eficiente para reabilitação da mandíbula. Assim, o presente estudo teve por objetivo desenvolver e avaliar a efetividade de dois modelos de mini-implantes dentários e um componente protético, cápsula de retenção para overdentures mini-implante retidas. Para tal, um total de 30 mini-implantes (n=10) foram utilizados: modelo comercial Intra-Lock® System, experimental rosqueado e experimental helicoidal. Ambos os mini-implantes desenvolvidos no estudo foram confeccionados em titânio Grau IV, nas dimensões de Ø 2,0 mm x 10 mm de comprimento e submetidos a tratamento de superfície nanométrico. O desempenho dos mesmos foi comparado ao modelo comercial selecionado quanto à estabilidade primária, por meio de torque de inserção e ensaio de arrancamento e à distribuição de tensões, através dos métodos fotoelástico e de correlação de imagens digitais (CID). Foram realizados carregamentos puntiformes axiais e oblíquos (inclinação de 30º do modelo), com cargas de 100 N para a fotoelasticidade e de 250 N axial e 100 N oblíquo para a CID. Para análise do componente protético foi utilizado o teste de resistência à fadiga. 60 cápsulas (n=20): Poliacetal, Politetrafluoretileno (PTFE) e o-ring convencional (Intra-Lock®) foram capturadas aos pares, com resina acrílica e submetidas a 3625 ciclos de inserção/remoção, simulando 30 meses de uso da overdenture. A deformação interna e externa dos componentes foi avaliada por meio de Estereomicroscópio Óptico. Os dados obtidos foram submetidos a ANOVA e teste de Tukey (&alpha;=0,05). O torque de inserção (TI) e ensaio de arrancamento apresentaram significância estatística para todos os modelos (p<0,05), sendo o TI maior para o mini-implante rosqueado e a força máxima de arrancamento para o modelo Intra-Lock®. Quanto à análise de tensões por meio da fotoelasticidade verificou-se de maneira geral, maiores tensões no terço médio e apical dos mini-implantes. O mesmo padrão foi observado para a CID, porém, neste caso, com tensões significativamente maiores (p<0,05) para os mini-implantes rosqueados na condição de carregamento axial, para o oblíquo não foram encontradas diferenças significativas (p>0,05). Quanto à análise dos componentes protéticos, a cápsula de poliacetal apresentou a maior retenção (p<0,05), seguida do o-ring e PTFE. Menor deformação foi observada para o o-ring (p<0,05) e maior deformação interna (p<0,05), após a realização da fadiga, para o poliacetal. O mini-implante rosqueado apresentou de modo geral estabilidade primária e distribuição de tensões comparável ao modelo comercial avaliado. O componente protético de poliacetal demonstrou superioridade em relação ao o-ring da Intra-Lock® quanto à força de retenção e apesar da maior deformação interna sofrida, sugere-se sua substituição após no mínimo 30 meses de uso da overdenture / Edentulism affects a large part of the world population, especially the elderly, generating loss of masticatory function, nutritional disorders, unfavorable esthetics and reduction of quality of life. As an alternative to these problems, overdentures implant retained have represented an efficient treatment modality for mandibular rehabilitation. Thus, the present study aimed to develop and evaluate the effectiveness of two models of dental mini-implants and a prosthetic component, retention caps for overdentures mini-implant retained. To do this, a total of 30 mini-implants (n=10) were used: Intra-Lock® System commercial model, experimental threaded and experimental helical. Both mini-implants developed in the study were made in Titanium Grade IV, in the dimensions of Ø 2.0 mm x 10 mm in length and submitted to a nanometric surface treatment. Their performance were compared to the commercial model selected for primary stability by means of insertion torque and pullout test and stress distribution using photoelastic and digital image correlation (DIC) methods. Axial and oblique punctiform loads (30º inclination of the model) were performed, with loads of 100 N for photoelasticity and 250 N axial and 100 N oblique for DIC. For the analysis of the prosthetic component, the fatigue strength test was used. 60 capsules (n=20): Polyacetal, Polytetrafluoroethylene (PTFE) and conventional O-ring (Intra-Lock®) were captured in pairs with acrylic resin and subjected to 3625 insertion/removal cycles, simulating 30 months of overdenture use. The internal and external deformation of the components was evaluated using an Optical Stereomicroscope. Data were submitted to ANOVA and Tukey\'s test (&alpha;=0.05). The insertion torque (IT) and pullout test were statistically significant for all models (p<0.05), with IT being highest for the threaded mini-implant and maximum pulling force for the Intra-Lock® model. As for stress analysis by photoelasticity, it was generally observed that there were higher tensions in the middle and apical third of the mini-implants. The same pattern was observed for the DIC, but in this case, with significantly higher stresses (p<0.05) for the mini-implants threaded in the axial loading condition, no significant differences were found for the oblique (p>0.05). As for the analysis of prosthetic components, the polyacetal caps presented the highest retention (p<0.05), followed by o-ring and PTFE. Lower deformation was observed for o-ring (p<0.05) and greater internal deformation (p<0.05), after fatigue, for polyacetal. The threaded mini-implant generally showed primary stability and strain distribution comparable to the commercial model evaluated. The polyacetal prosthetic component showed superiority over the Intra-Lock® o-ring for the retention force and despite the greater internal deformation suffered, it is suggested to replace it after at least 30 months of overdenture use
10

Análise in vitro da estabilidade de próteses totais superiores implantossuportadas e implantorretidas / Analisys of the stability of maxillary overdentures An in vitro study

Aline Tany Posch 25 February 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Os sistemas de retenção utilizados em próteses totais sobre implante (sobredentaduras) tem sido discutidos ao longo das últimas décadas a fim de se obter uma padronização a respeito do tratamento clínico desses pacientes. Considerando o importante papel da estabilidade das próteses para a eficiência mastigatória, bem como para elaboração do plano de tratamento adequado, o objetivo deste estudo foi avaliar a estabilidade das próteses implantossuportadas e/ou implantorretidas, utilizando para isso um estudo in vitro que simulou a força de mordida. Materiais e Métodos: Foram testadas quatro tipo diferentes de próteses totais: 1) G1 Prótese Total Removível Convencional; 2) G2 - Próteses Total Removível sobre Implantes (Overdenture), retida pelo sistema ERA; 3) G3 Prótese Total Removível sobre Implantes (Overdenture), retida pelo sistema de Barra com clipes e Encaixes - ORCE; e 4) G4 - Prótese Total Fixa sobre Implantes, seguindo o protocolo Brånemark e utilizando o sistema de barras-distais da marca Neodent. Cada grupo foi submetido ao carregamento em pontos específicos, localizados sobre os elementos 16 (F=300N), 26 (F=300N) e na região anterior 11/21(F=100N). A aferição da estabilidade foi feita através da mensuração do deslocamento vertical da prótese durante o a aplicação da força e a distância do local do carregamento, sobre os elementos 16, 26 e na região anterior, nos elementos 11 e 21. Os dados passaram no teste de normalidade de Shapiro-Wilk e foram submetidos à análise de variância ANOVA e à comparação múltipla através do teste de Bonferroni (p<0.05) Resultados: O tipo de sistema utilizado influenciou na movimentação vertical da prótese na região posterior contralateral à aplicação de força, sendo a movimentação vertical G1 > G2 > G3 &#8805; G4. Na movimentação vertical da prótese nos dentes anteriores, quando a força foi aplicada nos dentes posteriores (rotação para posterior), a movimentação vertical foi de G1 > G2 > G3 &#8805; G4. Durante a rotação para posterior, quando a força foi aplicada nos dentes anteriores (rotação para anterior) e a movimentação medida nos dentes posteriores, o comportamento foi de G1 > G2 > G3 > G4. Conclusão: Em duas das três situações testadas não houve diferença estatística entre a movimentação vertical entre o G3 e o G4, sugerindo que a estabilidade da overdenture retida por barra com clipes e encaixes se comportou, em relação a estabilidade, semelhante a prótese fixa sobre implantes. / The retain systems used by the complete dentures have been discussed over the past decades in order to achieve a standardization regarding to the clinical treatment of the patients. Considering the important meaning of the stability of dentures for chewing efficiency and for planning appropriate treatment, the aim of this study was to evaluate the stability of the implant-supported and implant-retained prosthesis, using an in vitro study that simulated the bite force. Materials and Methods: Four different types of dentures were tested: 1) G1 - Conventional Denture; 2) G2 Overdenture retained by the ERA system ; 3) G3 - Overdenture retained by bar system using clipes and fittings; and 4) G4 - Total implant-supported Prosthesis, following the Brånemark protocol and using Neodent`s distal bar. Each group was subjected to loading at specific points, located on the elements 16, 26 (F = 300Ncm) and at the anterior region 11/21 (F = 100Ncm). The measurement of vertical displacement during the test was taken out-lying from the loading area and at the elements 16, 26 and in the anterior region, at the element 11/21. Results: The data was analyzed by Shapiro -Wilk normality Test and than by ANOVA and multiple comparisons using the Bonferroni test. Conclusions: The retention system have influenced the vertical movement of the prosthesis in the posterior region contralateral to force application point, with the vertical movement as G1 > G2 > G3 > G4. In the vertical movement of the prosthesis at anterior point, when the force was applied to the posterior teeth, the vertical movement was G1 > G2 > G3 > G4. When the load was applied to the anterior teeth and movement was measured ate the posterior teeth, the behavior was G1 > G2 > G3 > G4. In two of the three situations simulated, there was no statistical difference between the vertical movement between the G3 and G4, suggesting that the stability of overdentures retained by bar with clips and fittings performed like fixed prosthesis.

Page generated in 0.3934 seconds