• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 11
  • 6
  • 1
  • Tagged with
  • 39
  • 26
  • 23
  • 21
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Estudo comparativo do efeito da retenção a barra no ciclo mastigatório de pacientes usuários de overdentures" / Comparative study of the bar retention effect in the masticatory cycle in overdenture wearers.

Carradori, Andreia 02 September 2005 (has links)
A reabilitação dos pacientes edentados totais tem sido um desafio para os profissionais da área, que têm a responsabilidade de restabelecer a função e a estética alteradas com a perda progressiva dos dentes. Com o surgimento das reabilitações protéticas com implantes, o prognóstico dessas reabilitações melhorou e a satisfação dos pacientes aumentou. O presente trabalho teve como objetivo analisar as alterações que poderiam ou não estar presentes no ciclo mastigatório de pacientes portadores de prótese total convencional superior e overdentures mandibulares, com e sem a retenção da barra, simulando nesta última condição, uma prótese apenas mucoso-suportada. Foram selecionados 9 pacientes com idade entre 35 e 58 anos, sem histórico ou sintomatologia de disfunção da articulação têmporo-mandibular e que foram reabilitados na Clínica da Fundação para o Desenvolvimento Científico e Tecnológico da Odontologia (FUNDECTO). Os registros foram obtidos através do aparelho Arcus Digma (Kavo Dental GmbH & Co. KG, Alemanha) que permite a análise dos movimentos mandibulares nas suas três dimensões. No intuito de simular uma mastigação normal onde o alimento exigisse um esforço contínuo do paciente mesmo após a degradação inicial do mesmo, optou-se por pedaços de cenoura crua padronizados em 1 cm 3 . O paciente não foi induzido quanto ao lado de mastigação e esse registro foi feito em dois momentos: primeiro com a manutenção da barra e segundo com a remoção da mesma. Escolheu-se o plano frontal para a avaliação dos resultados. Os ciclos mastigatórios foram avaliados quanto a sua forma, largura máxima, comprimento máximo e área total, e os registros com e sem a barra foram comparados. Quanto à forma, encontrou-se uma variação interindividual grande, porém, uma similaridade marcante quando se analisaram os dois registros de um mesmo paciente, o que evidenciou a existência de um padrão de caráter individual. Nos registros com a barra, pôde-se notar, de modo geral, que os ciclos foram mais regulares, lisos e com melhor direcionamento que nos registros sem a barra, sugerindo uma mastigação mais efetiva. Em relação à largura, 4 pacientes apresentaram aumento dos valores quando dos registros com a barra. Para a altura, 5 pacientes com a barra apresentaram aumento desta variável. Quanto à área total dos ciclos, 7 pacientes apresentaram aumento da área total com a barra, o que sugere que nessa condição, no geral, os ciclos foram mais largos. A análise estatística com a aplicação do teste não paramétrico de Wilcoxon adotando o nível de significância de 5%, para p menor ou igual a 0,05, não encontrou diferenças significantes para os registros com e sem a barra. Os resultados demonstraram que existe um padrão individual do ciclo mastigatório para cada paciente e uma grande variação interindividual do mesmo. Existem pequenas, porém, importantes diferenças na conformação geral do ciclo quando se compararam os registros com e sem barra. / Rehabilitating edentulous patients has been a challenge for the professionals that have the responsibility of restoring the function and esthetics altered by the looseness of the teeth. The aim of the present research was to evaluate the changes that could exist in the masticatory cycle of an upper conventional complete denture and mandibular overdentures wearers, with and without the bar fixation, simulating in this last condition, a conventional denture. Nine patients aged from 35 to 58 years old without signs or symptoms of join disfunction were selected, and rehabilitated in the Fundação para o Desenvolvimento Científico e Tecnológico da Odontologia (FUNDECTO). The recordings were obtained from Arcus Digma (Kavo Dental GmbH & Co. KG) that is capable to register the mandibular movements in three dimensions. In order to simulate a normal mastication, when the food would ask the patient a continuous effort even after the first strokes, the carrot measuring 1 cm 3 was used. The patient was not induced to a preferred side of mastication and the recording was made in two times: first with the maintenance of the bar and second with its removal. The frontal plane was chosen to evaluate the results. The form, area, width and length of the masticatory cycles were evaluated and the results with and without the bar fixation were compared. Concerning the form of the cycle, a large inter-individual variation was found. However, a similar pattern was presented when analyzing the two recordings of a single patient, what means that an individual pattern exists for each person. The cycles with the bar were, generally, more regular, smooth, and with a better direction when compared with the recordings without the bar, suggesting a more effective mastication. Regarding the width, four patients presented higher values for the recordings with the bar fixation. Five patients had their recording changed to higher values with the bar fixation when analyzing the length of the cycles. Seven patients presented an enlargement of the total area of the masticatory cycles when the recordings were made with de bar fixation, what suggests that, with the bar, the cycles were generally larger. Test of differences between the two registrations were made by means of the Wilcoxon test, which did not find significant differences between the results with and without the bar fixation. The results demonstrated an individual pattern of the masticatory cycle for each patient and a large interindividual variation. Having considered all aspects, when comparing the results with and without the bar fixation, there are few but important differences in the general pattern of the masticatory cycle.
2

Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonization

Cunha, Tatiana Ramirez 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (&alpha;=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
3

Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonization

Tatiana Ramirez Cunha 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (&alpha;=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
4

Análise da durabilidade, retenção e tensão em overdentures retidas por implantes associadas ou não a mini-implantes posteriores / Durability, retention and stress analysis of implants-retained overdentures associated or not to posterior mini-implants

Alves, Suleima do Vale 02 June 2017 (has links)
O objetivo desse estudo in vitro foi analisar a durabilidade, retenção e tensão gerada nos implantes de overdenture retidas por sistema bola/O\'ring ou barra/clipe, associados ou não a mini-implantes na região posterior da mandíbula. Foram utilizados implantes anteriores cone-Morse (3,75 x 11 mm) e mini-implantes de corpo único (2 x 10 mm) e os grupos divididos em (n=12): G2O: overdenture sobre 2 implantes com bola/O´rings; G1B: overdenture sobre 2 implantes com barra/clipe; G4O: overdenture sobre 2 implantes com bola/O´rings e 2 mini-implantes na região posterior; G1B2O: overdenture sobre 2 implantes com barra/clipe e 2 mini-implantes na região posterior. Para avaliação qualitativa das áreas de compressão e/ou tração nos modelos em poliuretano, foi realizado o método de correlação de imagens digitais, com carregamento oclusal (300 N) e pontual (250 N) com captura em vista frontal e lateral dos modelos experimentais. Foi realizado ensaio de fadiga acelerada progressiva com cargas de 80 N, 140 N, 200 N, 260 N, 320 N e 380 N, frequência de 5Hz, totalizando 120.000 ciclos. Para avaliação da retenção os modelos foram submetidos a ensaio de tração previamente a termociclagem (Tempo 1), após 200 N (Tempo 2) e após 380 N (Tempo 3) e a força de retenção foi registradas em triplicata e a média obtida em cada tempo. A análise da durabilidade dos componentes retentivos foi realizada após os ensaios de tração nos tempos determinados por microscopia óptica. As imagens da aplicação de carga oclusal, mostraram que as tensões nos grupos 1B e 1B2O foram semelhantes, nos grupos 2O e 4O apresentaram tensões de tração na região anterior, porém no grupo 4O houve melhor distribuição por toda área analisada. Na aplicação de carga pontual, todos os modelos apresentaram tensões de compressão na região posterior e de tração na anterior, porém com maior intensidade nos modelos 2O e 4O, e menor intensidade nos modelos 1B e 1B2O. Nas análises sobre a retenção dos componentes, não houve diferença significativa (p < 0,05) entre os grupos 1B-1B2O, porém houve diferença significativa entre os grupos 2O-4O, notando maior força retentiva no grupo 4O. As comparações entre os grupos, 1B-2O e 1B2O-4O houve diferença significativa, sendo que os grupos com sistema barra/clipe obtiveram maior retenção que os grupos com O´rings. Nas imagens microscópicas não houve diferença significativa na estrutura interna dos O´rings, porém houve diferença significativa nos clipes. Conclui-se que a durabilidade, retenção e distribuição de tensão não se altera com a colocação de mini-implantes posteriores em overdentures com sistema retentivo barra/clipe. Com sistema retentivo bola/O\'ring a instalação de mini-implantes aumentou a força de retenção e favoreceu a distribuição das tensões, reduzindo a alavanca para posterior. / The purpose of this in vitro study was to analyze the durability, retention and strength caused for implants-retained overdentures by ball/O-ring system or bar/clip, associated or not mini-implants in the posterior region of the mandible. Anterior Morse taper connection implants (3.75 x 11 mm) and single-body mini-implants (2 x 10 mm) were used and the groups divided to (n=12): G2O: implants-retained overdentures 2 implants with ball/O-rings ; G1B: implants-retained overdentures 2 bar/clip implants; G4O: implants-retained overdentures 2 implants with ball/O-rings and 2 mini-implants in the posterior region ; G1B2O: implants-retained overdentures 2 implants with bar/clip and 2 mini-implants in the posterior region. For the qualitative evaluation of compression and/or traction areas in polyurethane models, a digital image correlation method (DIC) with occlusal (300 N) and punctual (250 N) loading was applied with frontal and lateral views of the experimental models. An accelerated progressive fatigue test with loads of 80 N, 140 N, 200 N, 260 N, 320 N and 380 N, frequency of 5 Hz, completing120,000 cycles. In order to evaluate the retention force, the models were submitted to traction force, previously to thermocycling (Time 1) after 200 N (Time 2) and posteriorly 380 N (Time 3), being the retention force recorded in triplicate. The durability analysis, by optic microscopy, of the retentive components was performed after the traction tests at the determined times. The application images of the occlusal load, showed that the stress in groups 1B and 1B2O were similar, in groups 2O and 4O presented stress in the anterior region, but in the 4O group, there was better distribution throughout the analyzed area. In the application of punctual loading, all the models presented compression tensions in the posterior region and traction in the anterior one, but with greater intensity in the 2O and 4O models, and lower intensity in the 1B and 1B2O models. In the retention analyzes of the components, there was no significant difference (p <0.05) between groups 1B-1B2O, but there was a significant difference between groups 2O-4O, noting a higher retentive force in the 4O group. The comparisons between the groups, 1B-2O and 1B2O-4O showed a significant difference, and the groups with bar/clip systems obtained higher retention than the groups with O-rings. In the microscopic images, there was no significant difference in the O-rings internal structure, but there was a significant difference in the clips images. It was concluded that the durability, retention and stress distribution do not change with the placement of posterior mini-implants in overdentures with retentive bar/clip system. With retentive system ball/O-ring the installation of mini-implants increased the retention force and favored much the distribution of the stress, thus reducing the forefoot leverage to the posterior part of the prosthesis.
5

Avaliação clínico-radiográfica e estabilidade implantar em overdenture mandibular retida por implante unitário / Clinical radiographic and implant stability evaluation of single implant-retained mandibular overdentures

Nogueira, Túlio Eduardo 03 April 2014 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2015-03-02T14:42:20Z No. of bitstreams: 2 Dissertação - Tulio Eduardo Nogueira - 2014.pdf: 2052325 bytes, checksum: a10ec63df3d099550385e5493ffd24d6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-03-02T15:29:11Z (GMT) No. of bitstreams: 2 Dissertação - Tulio Eduardo Nogueira - 2014.pdf: 2052325 bytes, checksum: a10ec63df3d099550385e5493ffd24d6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-02T15:29:11Z (GMT). No. of bitstreams: 2 Dissertação - Tulio Eduardo Nogueira - 2014.pdf: 2052325 bytes, checksum: a10ec63df3d099550385e5493ffd24d6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-04-03 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / Objective: To conduct a longitudinal evaluation of marginal bone loss, peri-implant aspects and stability in single implant used to retain mandibular overdenture, and to evaluate outcomes related to the overdenture. Methods: Forty-five completely edentulous individuals were treated using mandibular overdenture retained by a single implant (Titamax IT Cortical, Neodent, Curitiba, Brazil) opposed to conventional dentures. According to the primary stability obtained in the implant placement patients were treated with an immediate loading protocol when torque was at least 30 Ncm and implant stability quotient (ISQ) at least 60. In cases of values below cited conventional loading protocol were adopted. O’Ring attachment system from two different commercially available companies were used and allocated systematically between subjects. Follow-up evaluations were performed immediately and at 3 and 6 months after implant placement, when parameters related to implant stability, periimplant tissue aspects, implant survival rate and need for the maintenance of the overdenture were noted. Results: 38 (84.4%) of 45 patients received immediate loaded implants. Implant failure occurred in 3 cases, 2 of them in the conventional loading group (early loss before implant loading). There was an increase in ISQ values in subsequent periods after implant placement, evidenced between baseline and 6 months (p=0.004) and between 3 and 6 months (p<0.001). The mean marginal bone loss at follow-up was 0.50 mm (SD=0.66). It was observed gradual reduction of the gingival height up to 6 months (p=0.006), as well as progressive reduction in plaque index (p=0.028) and bleeding on probing (p=0.021). There was no difference in clinical condition concerning the attachments that were compared. However, Neodent attachments showed better clinical performance and lower replacement rates (p=0.014). Conclusion: This clinical study suggested that the single implant-retained mandibular overdenture is a feasible treatment for mandibular edentulousness, showing favorable clinical and radiographic periimplant outcomes as well as maintenance of the implant stability. / Objetivo: Realizar avaliação longitudinal da perda óssea marginal, aspectos periimplantares e da estabilidade em implante unitário utilizado para retenção de overdenturs mandibular, além de avaliar desfechos relacionados às próteses. Métodos: Quarenta e cinco indivíduos desdentados totais foram tratados com overdenture mandibular retida por implante unitário em oposição a prótese total superior convencional. De acordo com a estabilidade primária obtida no momento de instalação do implante, os indivíduos foram tratados com protocolo de carregamento do implante imediato quando o torque final de instalação era de no mínimo 30 Ncm e o quociente de estabilidade implantar (ISQ) de no mínimo 60. Em casos de valores abaixo dos citados, era adotado o protocolo de carga convencional. Utilizou-se o sistema de retenção O’Ring de duas marcas comerciais, alocados sistematicamente entre os sujeitos. Os desfechos avaliados foram: estabilidade do implante, aspectos teciduais periimplantares e necessidade de manutenção das próteses. O acompanhamento foi realizado nos períodos imediato, 3 e 6 meses após instalação dos implantes. Resultado: Dos 45 pacientes, 38 (84,4%) receberam implante com carga imediata. Houve perda de 3 implantes, sendo 2 no grupo de carga convencional (perda antes do carregamento do implante). O valor médio de ISQ aumentou nos períodos subsequentes à instalação dos implantes, entre o período inicial e de 6 meses (p=0,004) e entre os períodos de 3 e 6 meses (p<0,001). A perda óssea marginal média no período de acompanhamento foi de 0,50 mm (DP=0,66). Foi observada redução progressiva da altura gengival até o período de 6 meses (p=0,006), resultado da acomodação dos tecidos periimplantares, bem como diminuição do índice de placa (p=0,028) e sangramento à sondagem (p=0,021). Não houve diferença na condição clínica em relação às marcas comerciais do sistema de retenção, porém a marca Neodent apresentou desempenho clínico superior com menor ocorrência de substituição da matriz de retenção e maior tempo até necessidade de substituição (p=0,014). Conclusão: O presente estudo clínico mostrou resultados satisfatórios do tratamento com overdenture mandibular retida por implante unitário em relação aos parâmetros clínicos e radiográficos, além da manutenção da estabilidade do implante.
6

Análise da durabilidade, retenção e tensão em overdentures retidas por implantes associadas ou não a mini-implantes posteriores / Durability, retention and stress analysis of implants-retained overdentures associated or not to posterior mini-implants

Suleima do Vale Alves 02 June 2017 (has links)
O objetivo desse estudo in vitro foi analisar a durabilidade, retenção e tensão gerada nos implantes de overdenture retidas por sistema bola/O\'ring ou barra/clipe, associados ou não a mini-implantes na região posterior da mandíbula. Foram utilizados implantes anteriores cone-Morse (3,75 x 11 mm) e mini-implantes de corpo único (2 x 10 mm) e os grupos divididos em (n=12): G2O: overdenture sobre 2 implantes com bola/O´rings; G1B: overdenture sobre 2 implantes com barra/clipe; G4O: overdenture sobre 2 implantes com bola/O´rings e 2 mini-implantes na região posterior; G1B2O: overdenture sobre 2 implantes com barra/clipe e 2 mini-implantes na região posterior. Para avaliação qualitativa das áreas de compressão e/ou tração nos modelos em poliuretano, foi realizado o método de correlação de imagens digitais, com carregamento oclusal (300 N) e pontual (250 N) com captura em vista frontal e lateral dos modelos experimentais. Foi realizado ensaio de fadiga acelerada progressiva com cargas de 80 N, 140 N, 200 N, 260 N, 320 N e 380 N, frequência de 5Hz, totalizando 120.000 ciclos. Para avaliação da retenção os modelos foram submetidos a ensaio de tração previamente a termociclagem (Tempo 1), após 200 N (Tempo 2) e após 380 N (Tempo 3) e a força de retenção foi registradas em triplicata e a média obtida em cada tempo. A análise da durabilidade dos componentes retentivos foi realizada após os ensaios de tração nos tempos determinados por microscopia óptica. As imagens da aplicação de carga oclusal, mostraram que as tensões nos grupos 1B e 1B2O foram semelhantes, nos grupos 2O e 4O apresentaram tensões de tração na região anterior, porém no grupo 4O houve melhor distribuição por toda área analisada. Na aplicação de carga pontual, todos os modelos apresentaram tensões de compressão na região posterior e de tração na anterior, porém com maior intensidade nos modelos 2O e 4O, e menor intensidade nos modelos 1B e 1B2O. Nas análises sobre a retenção dos componentes, não houve diferença significativa (p < 0,05) entre os grupos 1B-1B2O, porém houve diferença significativa entre os grupos 2O-4O, notando maior força retentiva no grupo 4O. As comparações entre os grupos, 1B-2O e 1B2O-4O houve diferença significativa, sendo que os grupos com sistema barra/clipe obtiveram maior retenção que os grupos com O´rings. Nas imagens microscópicas não houve diferença significativa na estrutura interna dos O´rings, porém houve diferença significativa nos clipes. Conclui-se que a durabilidade, retenção e distribuição de tensão não se altera com a colocação de mini-implantes posteriores em overdentures com sistema retentivo barra/clipe. Com sistema retentivo bola/O\'ring a instalação de mini-implantes aumentou a força de retenção e favoreceu a distribuição das tensões, reduzindo a alavanca para posterior. / The purpose of this in vitro study was to analyze the durability, retention and strength caused for implants-retained overdentures by ball/O-ring system or bar/clip, associated or not mini-implants in the posterior region of the mandible. Anterior Morse taper connection implants (3.75 x 11 mm) and single-body mini-implants (2 x 10 mm) were used and the groups divided to (n=12): G2O: implants-retained overdentures 2 implants with ball/O-rings ; G1B: implants-retained overdentures 2 bar/clip implants; G4O: implants-retained overdentures 2 implants with ball/O-rings and 2 mini-implants in the posterior region ; G1B2O: implants-retained overdentures 2 implants with bar/clip and 2 mini-implants in the posterior region. For the qualitative evaluation of compression and/or traction areas in polyurethane models, a digital image correlation method (DIC) with occlusal (300 N) and punctual (250 N) loading was applied with frontal and lateral views of the experimental models. An accelerated progressive fatigue test with loads of 80 N, 140 N, 200 N, 260 N, 320 N and 380 N, frequency of 5 Hz, completing120,000 cycles. In order to evaluate the retention force, the models were submitted to traction force, previously to thermocycling (Time 1) after 200 N (Time 2) and posteriorly 380 N (Time 3), being the retention force recorded in triplicate. The durability analysis, by optic microscopy, of the retentive components was performed after the traction tests at the determined times. The application images of the occlusal load, showed that the stress in groups 1B and 1B2O were similar, in groups 2O and 4O presented stress in the anterior region, but in the 4O group, there was better distribution throughout the analyzed area. In the application of punctual loading, all the models presented compression tensions in the posterior region and traction in the anterior one, but with greater intensity in the 2O and 4O models, and lower intensity in the 1B and 1B2O models. In the retention analyzes of the components, there was no significant difference (p <0.05) between groups 1B-1B2O, but there was a significant difference between groups 2O-4O, noting a higher retentive force in the 4O group. The comparisons between the groups, 1B-2O and 1B2O-4O showed a significant difference, and the groups with bar/clip systems obtained higher retention than the groups with O-rings. In the microscopic images, there was no significant difference in the O-rings internal structure, but there was a significant difference in the clips images. It was concluded that the durability, retention and stress distribution do not change with the placement of posterior mini-implants in overdentures with retentive bar/clip system. With retentive system ball/O-ring the installation of mini-implants increased the retention force and favored much the distribution of the stress, thus reducing the forefoot leverage to the posterior part of the prosthesis.
7

"Estudo comparativo do efeito da retenção a barra no ciclo mastigatório de pacientes usuários de overdentures" / Comparative study of the bar retention effect in the masticatory cycle in overdenture wearers.

Andreia Carradori 02 September 2005 (has links)
A reabilitação dos pacientes edentados totais tem sido um desafio para os profissionais da área, que têm a responsabilidade de restabelecer a função e a estética alteradas com a perda progressiva dos dentes. Com o surgimento das reabilitações protéticas com implantes, o prognóstico dessas reabilitações melhorou e a satisfação dos pacientes aumentou. O presente trabalho teve como objetivo analisar as alterações que poderiam ou não estar presentes no ciclo mastigatório de pacientes portadores de prótese total convencional superior e overdentures mandibulares, com e sem a retenção da barra, simulando nesta última condição, uma prótese apenas mucoso-suportada. Foram selecionados 9 pacientes com idade entre 35 e 58 anos, sem histórico ou sintomatologia de disfunção da articulação têmporo-mandibular e que foram reabilitados na Clínica da Fundação para o Desenvolvimento Científico e Tecnológico da Odontologia (FUNDECTO). Os registros foram obtidos através do aparelho Arcus Digma (Kavo Dental GmbH & Co. KG, Alemanha) que permite a análise dos movimentos mandibulares nas suas três dimensões. No intuito de simular uma mastigação normal onde o alimento exigisse um esforço contínuo do paciente mesmo após a degradação inicial do mesmo, optou-se por pedaços de cenoura crua padronizados em 1 cm 3 . O paciente não foi induzido quanto ao lado de mastigação e esse registro foi feito em dois momentos: primeiro com a manutenção da barra e segundo com a remoção da mesma. Escolheu-se o plano frontal para a avaliação dos resultados. Os ciclos mastigatórios foram avaliados quanto a sua forma, largura máxima, comprimento máximo e área total, e os registros com e sem a barra foram comparados. Quanto à forma, encontrou-se uma variação interindividual grande, porém, uma similaridade marcante quando se analisaram os dois registros de um mesmo paciente, o que evidenciou a existência de um padrão de caráter individual. Nos registros com a barra, pôde-se notar, de modo geral, que os ciclos foram mais regulares, lisos e com melhor direcionamento que nos registros sem a barra, sugerindo uma mastigação mais efetiva. Em relação à largura, 4 pacientes apresentaram aumento dos valores quando dos registros com a barra. Para a altura, 5 pacientes com a barra apresentaram aumento desta variável. Quanto à área total dos ciclos, 7 pacientes apresentaram aumento da área total com a barra, o que sugere que nessa condição, no geral, os ciclos foram mais largos. A análise estatística com a aplicação do teste não paramétrico de Wilcoxon adotando o nível de significância de 5%, para p menor ou igual a 0,05, não encontrou diferenças significantes para os registros com e sem a barra. Os resultados demonstraram que existe um padrão individual do ciclo mastigatório para cada paciente e uma grande variação interindividual do mesmo. Existem pequenas, porém, importantes diferenças na conformação geral do ciclo quando se compararam os registros com e sem barra. / Rehabilitating edentulous patients has been a challenge for the professionals that have the responsibility of restoring the function and esthetics altered by the looseness of the teeth. The aim of the present research was to evaluate the changes that could exist in the masticatory cycle of an upper conventional complete denture and mandibular overdentures wearers, with and without the bar fixation, simulating in this last condition, a conventional denture. Nine patients aged from 35 to 58 years old without signs or symptoms of join disfunction were selected, and rehabilitated in the Fundação para o Desenvolvimento Científico e Tecnológico da Odontologia (FUNDECTO). The recordings were obtained from Arcus Digma (Kavo Dental GmbH & Co. KG) that is capable to register the mandibular movements in three dimensions. In order to simulate a normal mastication, when the food would ask the patient a continuous effort even after the first strokes, the carrot measuring 1 cm 3 was used. The patient was not induced to a preferred side of mastication and the recording was made in two times: first with the maintenance of the bar and second with its removal. The frontal plane was chosen to evaluate the results. The form, area, width and length of the masticatory cycles were evaluated and the results with and without the bar fixation were compared. Concerning the form of the cycle, a large inter-individual variation was found. However, a similar pattern was presented when analyzing the two recordings of a single patient, what means that an individual pattern exists for each person. The cycles with the bar were, generally, more regular, smooth, and with a better direction when compared with the recordings without the bar, suggesting a more effective mastication. Regarding the width, four patients presented higher values for the recordings with the bar fixation. Five patients had their recording changed to higher values with the bar fixation when analyzing the length of the cycles. Seven patients presented an enlargement of the total area of the masticatory cycles when the recordings were made with de bar fixation, what suggests that, with the bar, the cycles were generally larger. Test of differences between the two registrations were made by means of the Wilcoxon test, which did not find significant differences between the results with and without the bar fixation. The results demonstrated an individual pattern of the masticatory cycle for each patient and a large interindividual variation. Having considered all aspects, when comparing the results with and without the bar fixation, there are few but important differences in the general pattern of the masticatory cycle.
8

Comparison of retentive properties of two attachment systems in mandibular overdentures - an in vitro study

Satti, Asim Alsadig January 2013 (has links)
>Magister Scientiae - MSc / Aim: The aim of this study is to test and compare the retentive properties of two types of attachments i.e. Locator® and OT equator in a mandibular overdenture placed over 2 implants.
9

A comparative study to evaluate patient satisfaction with conventional dentures and implant retained overdentures.

Al-Makki, Amjad January 2006 (has links)
<p><span style="font-size: 8pt / " text-align:="" font-family:="" color:="">The edentulous jaw is a common feature in elderly patients that had lost their teeth during life due to local reasons such as poor oral hygiene and dental caries as well as periodontal disease. Hence these patients are the victims of biological phenomenona that lead to difficulties in different aspects of patient comfort with dentures. Clinicians are always concerned to minimize these difficulties and increase patient comfort through manufacturing a proper prosthesis to substitute for the loss of the natural teeth as well as the surrounding structures for optimum satisfaction and improved quality of life of the patient. The aim of this study was to evaluate patient satisfaction regarding function and aesthetics with conventional mandibular dentures and implant retained mandibular overdentures in denture wearers.</span></p>
10

A comparative study to evaluate patient satisfaction with conventional dentures and implant retained overdentures.

Al-Makki, Amjad January 2006 (has links)
<p><span style="font-size: 8pt / " text-align:="" font-family:="" color:="">The edentulous jaw is a common feature in elderly patients that had lost their teeth during life due to local reasons such as poor oral hygiene and dental caries as well as periodontal disease. Hence these patients are the victims of biological phenomenona that lead to difficulties in different aspects of patient comfort with dentures. Clinicians are always concerned to minimize these difficulties and increase patient comfort through manufacturing a proper prosthesis to substitute for the loss of the natural teeth as well as the surrounding structures for optimum satisfaction and improved quality of life of the patient. The aim of this study was to evaluate patient satisfaction regarding function and aesthetics with conventional mandibular dentures and implant retained mandibular overdentures in denture wearers.</span></p>

Page generated in 0.4603 seconds