Novo sensor de vazão de fluidos com foco em aplicações biomedicas / New fluid flow sensor aimed at biomedical applications

Orientadores: Antonio Augusto Fasolo Quevedo, Waldir Antonio Bizzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T20:06:15Z (GMT). No. of bitstreams: 1
Ramos_AndredePaula_M.pdf: 3634888 bytes, checksum: 6ac215157ad6cab344d793b24a2bc1cd (MD5)
Previous issue date: 2009 / Resumo: O espirômetro é um dispositivo que avalia a ventilação pulmonar. Este é um trabalho preliminar que propõe um sensor eletromecânico de fluxo com foco na aplicação biomédica de espirometria. O sensor consiste de um corpo rombudo, introduzido em um cano por um orifício, e um acelerômetro. A colisão das partículas do fluido contra o corpo rombudo gera vórtices, que por sua vez induzem vibrações no corpo. Forças de arrasto também estão presentes e tendem a movimentar o corpo. Os movimentos decorrentes do escoamento são captados pelo acelerômetro, que é posicionado na porção do corpo rombudo externa ao cano, evitando o contato do elemento eletrônico (acelerômetro) com o fluido, o que pode facilitar procedimentos de esterilização da luz do cano. Foram analisados corpos rombudos em forma de lâmina (com e sem massa adicional) e cilindro. O procedimento experimental consistiu no estabelecimento de seis regimes permanentes de entrada (vazão de ar) e na captura do sinal de resposta do sensor (nos três eixos). Foram coletadas 24 respostas do sensor para cada um dos regimes e posteriormente foram levantadas as curvas do sensor e realizadas análises estatísticas. Resultados significativos foram encontrados para o eixo do acelerômetro paralelo ao fluxo. Para a lâmina, o Valor Eficaz (RMS) do sinal foi proporcional à vazão com linearidade e coeficiente de correlação variando, respectivamente, de 19% e R2 = 0,99058, para o ensaio sem massa adicional, a até 8,4% e R2 = 0,9741, para o ensaio com massa adicional. O arrasto contínuo (valor médio da resposta) não guardou relação monotônica com o aumento da velocidade do ar. Já para o cilindro, o arrasto foi proporcional à vazão com altíssima linearidade e correlação (0,17% e R2 = 0,96347), mas o RMS do sinal não guardou relação monotônica com a vazão. Finalmente, embora sejam necessários mais estudos para utilizar o sensor proposto em equipamentos de espirometria, este trabalho demonstra que o sensor responde proporcionalmente às entradas (escoamento), dentro (de 0 a até 14 l/s) e fora da faixa (até 21 l/s) de operação do espirômetro com altos coeficientes de correlação e linearidade, além de respostas diferenciadas dadas diferentes entradas (vazões) comprovadas por ANOVA (valor de p < 10-15). / Abstract Spirometer is a device that evaluates pulmonary ventilation. This paper presents a preliminary study of a new electromechanical sensor, focused on the biomedical application of spirometry. The sensor is composed of a bluff body positioned inside a tube trough a hole, being a part of the body inside and another part outside of the tube, and an accelerometer positioned on the outside part. Within a fluid flow, the bluff body causes vortex shedding, and the vortexes induce vibrations on the body. Also, the viscous force of the flow drags the bluff body. Both movements are captured by the accelerometer and correlated with the flow. One important feature of this sensor is that the fluid does not contact any of the electronics, easing tube lumen sterilization procedures. Three types of bluff bodies were studied: two blades (with and without additional mass), and one cylinder. The experimental procedure consisted of establishing six different air flows and then capturing the accelerometer response in all of its three axes. Each of the collected signals from the accelerometer was divided in 24 parts, and these parts where analyzed through statistics; finally the mean response of the sensor was plotted. Best results were found in the accelerometer axis parallel to the air flow. In the blade tests, the RMS value of the AC component was proportional to the air flow, with linearity and correlation varying, respectively, from 19% and R2 = 0.99058 for the blade without mass, to 8.4% and R2 = 0.9741 for the blade with additional mass. It was observed that the mass addition reduced in a meaningful way the response variances. Yet the viscous force (DC value) did not respond in a monotonic way with the increase of air flow. On the other hand, the viscous force was the most expressive regarding the experiments with the cylinder (linearity of 0.17% and R2 = 0.96347), but the RMS value did not respond in a monotonic way. Finally, although further studies are needed to prove that the proposed sensor is efficient to be used in spirometry equipment, this study demonstrates that this sensor responds proportionally to the flow input, within (0 to 14 l/s) and without (up to 21 l/s) the spirometer operation range, with high correlation and linearity, as well as varying responses, given different inputs (flow), as verified by ANOVA test (p < 10-15). / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/261083
Date14 August 2018
CreatorsRamos, Andre de Paula
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Fasolo Quevedo, Antonio Augusto, 1970-, Bizzo, Waldir Antônio, 1955-, Quevedo, Antonio Augusto Fasolo, Ismail, Kamal Abdel Radi, Costa, Eduardo Tavares
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format100 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0066 seconds