• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cargas atomicas e energias de eletrons internos

Guadagnini, Paulo Henrique 12 August 2018 (has links)
Orientador: Roy E. Bruns / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-12T00:57:18Z (GMT). No. of bitstreams: 1 Guadagnini_PauloHenrique_D.pdf: 1175328 bytes, checksum: 1d90b1cecc2001bf1f665148300c3852 (MD5) Previous issue date: 2000 / Doutorado
2

Metodo de correção de frequencias e intensidades vibracionais por fatores de escala para grupos caracteristicos

Borges, Cleber Nogueira 14 February 2003 (has links)
Orientador: Roy Edward Bruns / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T16:09:18Z (GMT). No. of bitstreams: 1 Borges_CleberNogueira_M.pdf: 1387457 bytes, checksum: ce0ce2f697f4f0cc4d74355461ceecbf (MD5) Previous issue date: 2003 / Resumo: A exatidão das estimativas teóricas de intensidades e freqüências experimentais no infravermelho é limitada por diversos fatores. Um método para calcular fatores de escala de grupos característicos é proposto aqui. Fatores de escala para as intensidades e freqüências vibracionais de grupos característicos para três moléculas pequenas de referência: HCN, CzHz e CZH6 foram obtidos de resultados experimentais conhecidos e valores teóricos calculados. Estes fatores foram aplicados às freqüências das moléculas maiores: HC3N, C4Hz, C6Hz, CzNz, C4N2 e C6Nz. Além disso, fatores foram também aplicados às intensidades teóricas do HC3N. Melhor concordância entre freqüências vibracionais teóricas escaladas e seus valores experimentais correspondentes foi obtida pelo método proposto para os estiramentos C-H, C=C e C=N do que a determinada usando a técnica do cálculo da média relatada recentemente na literatura. Entretanto a técnica do cálculo da média fornece estimativas com maior exatidão para freqüências de deformação. Isto pode ser explicado pelo fato de que as deformações, ao contrário dos estiramentos, não são bons grupos característicos, pois sua forma varia muito entre moléculas diferentes. Os fatores de escala aplicados às intensidades foram menos eficazes em corrigir os valores teóricos. Além disso, estudos usando a análise de componentes principais na correção das intensidades não parecem promissores / Abstract: The accuracy of theoretical estimates of experimental frequencies and infrared intensities is limited by several factors. Here a method for calculating group characteristic scale factors is proposed. Scale factors for the vibrational frequencies and intensities of characteristic group for three small reference molecules: HCN, C2H2 and C2H6 are obtained from know experimental results and ca1culated theoretical values. These escale factors were applied to frequencies of larger molecules: HC3N, C4H2, C6H2, C2N2, C4N2 and C6N2. Furthermore scale factors were applied also to the theoretical intensities of HC3N. Better agreement between scaled theoretical vibrational frequencies and their corresponding experimental values were obtained by proposed method for the C-H, C=C and C=N stretches than are determine using averaged technique recent1y reported in the literature. However the averaged technique provides more accurate estimates for bending frequencies. This can be explained by the fact of that the bending, in contrast of the stretchings, are not good characteristic groups, therefore its form varies very between different molecules. The scale factors applied to intensities were less effective in correcting theoretical values. Furthermore studies using principal component analysis for correcting intensities does not seems promising / Mestrado / Mestre em Química
3

Análise de um oscilador não linear acoplado a um absorvedor tipo "snap through truss" (STTA) /

Godoy, Willians Roberto Alves de. January 2011 (has links)
Orientador: José Manoel Balthazar / Banca: Angelo Marcelo Tusset / Banca: Bento Rodrigues de Pontes Junior / Resumo: Alves Godoy, Willians Roberto, análise de um oscilador não linear acoplado a um absorvedor tipo "snap through truss" (stta). Bauru: Faculdade de Engenharia Mecânica, Universidade Estadual Paulista "Julio de Mesquita Filho", 2011, 102 pp., Dissertação (Mestrado). Recentemente os estudos sobre os absorvedores de energia vêm ganhando importância e destaque, principalmente na indústria automobilística e aeronáutica. Esse tipo de absorvedor permite fazer o controle passivo de um sistema vibratório. Na busca por melhores resultados, verificou-se a ansiedade da utilização de absorvedores não lineares, já que estes demonstraram poder receber energia além de uma pequena faixa de freqüencia de vibração do oscilador. Neste trabalho, considera-se o sistema vibratório constituído de um controlador passivo, o absorvedor tipo "snap-through truss" (STTA) acoplado a um oscilador submetido à excitação de um motor elétrico com uma excentricidade e potência limitada, caracterizando um oscilador não ideal (NIO). Busca-se utilizar o absorvedor STTA como um absorvedor não linear, aproveitando sua não linearidade geométrica, e estabelecer condições para que as amplitudes de movimento do sistema principal se tornem menores em determinadas condições. O principal objetivo nesse trabalho é obter as condições em que as amplitudes de movimento do NIO são menores durante a passagem pela ressonância, atenuando o efeito Sommerfeld. Os resultados obtidos nessa situação mostraram que o STTA é eficiente na redução das amplitudes de movimento do NIO antes e dentro da região de ressonâcia. Em contrapartida, ao sair da ressonância ficou evidente que o absorvedor deve ser retirado do sistema por implicar grandes amplitudes ao NIO. Além disso, um breve estudo da atuação do STTA sobre um sistema... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In recent years studies on energy absorver in order to reduce some systems vibration amplitudes has been gaining importance and prominence. This type of absorber allows vibrating system passive control. In order to better results, it was verified the need to use non-lienar absorbers as these have been shown to receive power more than a small band of vibration frequency of the oscillator. This work considers the vibrating system that consists of a snap-through truss absorber (STTA) coupled to an oscillator under excitation of an electric motor with an eccentricity and limited power, characterizing a non-ideal oscillator (NIO). it is aimed to use the absorver STTA as non-linear absorber and establish the conditions for the motion amplitudes become smaller under certain conditions the mian system. Therefore, this work aims to determine the conditions in which the main system, while it passes through resonance, has attenuated its amplitude of moviment and do not waste energy working in this condition. The main objective of this work is to obtain the conditions under which amplitudes motion of NIO are smaller in the passage through resonance, reducing the Sommerfeld effect. The results obtained in this situation showed that the STTA is effectie to reduce amplitudes motion of NIO before and within region of resonance. In contrast, out of resonance, it was evident that absorber must be removed from the system by imply large amplitudes to the NIO. In addition, a brief study of the performance of STTA on an ideal system was performed. In this situation, the STTA showed significant results in the attenuation of amplitudes motion of the oscillator. Therefore, this work shows that the use of snap-through truss absorber is a good alternative among passive abserbers in attenuation of Sommerfeld effect in non-ideal systems / Mestre
4

Análise de um oscilador não linear acoplado a um absorvedor tipo snap through truss (STTA)

Godoy, Willians Roberto Alves de [UNESP] 02 December 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-12-02Bitstream added on 2014-06-13T20:37:42Z : No. of bitstreams: 1 godoy_wra_me_bauru.pdf: 2181363 bytes, checksum: 2a22bf1c96c4aa3286f7cf3ced444283 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Alves Godoy, Willians Roberto, análise de um oscilador não linear acoplado a um absorvedor tipo snap through truss (stta). Bauru: Faculdade de Engenharia Mecânica, Universidade Estadual Paulista Julio de Mesquita Filho, 2011, 102 pp., Dissertação (Mestrado). Recentemente os estudos sobre os absorvedores de energia vêm ganhando importância e destaque, principalmente na indústria automobilística e aeronáutica. Esse tipo de absorvedor permite fazer o controle passivo de um sistema vibratório. Na busca por melhores resultados, verificou-se a ansiedade da utilização de absorvedores não lineares, já que estes demonstraram poder receber energia além de uma pequena faixa de freqüencia de vibração do oscilador. Neste trabalho, considera-se o sistema vibratório constituído de um controlador passivo, o absorvedor tipo snap-through truss (STTA) acoplado a um oscilador submetido à excitação de um motor elétrico com uma excentricidade e potência limitada, caracterizando um oscilador não ideal (NIO). Busca-se utilizar o absorvedor STTA como um absorvedor não linear, aproveitando sua não linearidade geométrica, e estabelecer condições para que as amplitudes de movimento do sistema principal se tornem menores em determinadas condições. O principal objetivo nesse trabalho é obter as condições em que as amplitudes de movimento do NIO são menores durante a passagem pela ressonância, atenuando o efeito Sommerfeld. Os resultados obtidos nessa situação mostraram que o STTA é eficiente na redução das amplitudes de movimento do NIO antes e dentro da região de ressonâcia. Em contrapartida, ao sair da ressonância ficou evidente que o absorvedor deve ser retirado do sistema por implicar grandes amplitudes ao NIO. Além disso, um breve estudo da atuação do STTA sobre um sistema... / In recent years studies on energy absorver in order to reduce some systems vibration amplitudes has been gaining importance and prominence. This type of absorber allows vibrating system passive control. In order to better results, it was verified the need to use non-lienar absorbers as these have been shown to receive power more than a small band of vibration frequency of the oscillator. This work considers the vibrating system that consists of a snap-through truss absorber (STTA) coupled to an oscillator under excitation of an electric motor with an eccentricity and limited power, characterizing a non-ideal oscillator (NIO). it is aimed to use the absorver STTA as non-linear absorber and establish the conditions for the motion amplitudes become smaller under certain conditions the mian system. Therefore, this work aims to determine the conditions in which the main system, while it passes through resonance, has attenuated its amplitude of moviment and do not waste energy working in this condition. The main objective of this work is to obtain the conditions under which amplitudes motion of NIO are smaller in the passage through resonance, reducing the Sommerfeld effect. The results obtained in this situation showed that the STTA is effectie to reduce amplitudes motion of NIO before and within region of resonance. In contrast, out of resonance, it was evident that absorber must be removed from the system by imply large amplitudes to the NIO. In addition, a brief study of the performance of STTA on an ideal system was performed. In this situation, the STTA showed significant results in the attenuation of amplitudes motion of the oscillator. Therefore, this work shows that the use of snap-through truss absorber is a good alternative among passive abserbers in attenuation of Sommerfeld effect in non-ideal systems
5

Novo sensor de vazão de fluidos com foco em aplicações biomedicas / New fluid flow sensor aimed at biomedical applications

Ramos, Andre de Paula 14 August 2018 (has links)
Orientadores: Antonio Augusto Fasolo Quevedo, Waldir Antonio Bizzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T20:06:15Z (GMT). No. of bitstreams: 1 Ramos_AndredePaula_M.pdf: 3634888 bytes, checksum: 6ac215157ad6cab344d793b24a2bc1cd (MD5) Previous issue date: 2009 / Resumo: O espirômetro é um dispositivo que avalia a ventilação pulmonar. Este é um trabalho preliminar que propõe um sensor eletromecânico de fluxo com foco na aplicação biomédica de espirometria. O sensor consiste de um corpo rombudo, introduzido em um cano por um orifício, e um acelerômetro. A colisão das partículas do fluido contra o corpo rombudo gera vórtices, que por sua vez induzem vibrações no corpo. Forças de arrasto também estão presentes e tendem a movimentar o corpo. Os movimentos decorrentes do escoamento são captados pelo acelerômetro, que é posicionado na porção do corpo rombudo externa ao cano, evitando o contato do elemento eletrônico (acelerômetro) com o fluido, o que pode facilitar procedimentos de esterilização da luz do cano. Foram analisados corpos rombudos em forma de lâmina (com e sem massa adicional) e cilindro. O procedimento experimental consistiu no estabelecimento de seis regimes permanentes de entrada (vazão de ar) e na captura do sinal de resposta do sensor (nos três eixos). Foram coletadas 24 respostas do sensor para cada um dos regimes e posteriormente foram levantadas as curvas do sensor e realizadas análises estatísticas. Resultados significativos foram encontrados para o eixo do acelerômetro paralelo ao fluxo. Para a lâmina, o Valor Eficaz (RMS) do sinal foi proporcional à vazão com linearidade e coeficiente de correlação variando, respectivamente, de 19% e R2 = 0,99058, para o ensaio sem massa adicional, a até 8,4% e R2 = 0,9741, para o ensaio com massa adicional. O arrasto contínuo (valor médio da resposta) não guardou relação monotônica com o aumento da velocidade do ar. Já para o cilindro, o arrasto foi proporcional à vazão com altíssima linearidade e correlação (0,17% e R2 = 0,96347), mas o RMS do sinal não guardou relação monotônica com a vazão. Finalmente, embora sejam necessários mais estudos para utilizar o sensor proposto em equipamentos de espirometria, este trabalho demonstra que o sensor responde proporcionalmente às entradas (escoamento), dentro (de 0 a até 14 l/s) e fora da faixa (até 21 l/s) de operação do espirômetro com altos coeficientes de correlação e linearidade, além de respostas diferenciadas dadas diferentes entradas (vazões) comprovadas por ANOVA (valor de p < 10-15). / Abstract Spirometer is a device that evaluates pulmonary ventilation. This paper presents a preliminary study of a new electromechanical sensor, focused on the biomedical application of spirometry. The sensor is composed of a bluff body positioned inside a tube trough a hole, being a part of the body inside and another part outside of the tube, and an accelerometer positioned on the outside part. Within a fluid flow, the bluff body causes vortex shedding, and the vortexes induce vibrations on the body. Also, the viscous force of the flow drags the bluff body. Both movements are captured by the accelerometer and correlated with the flow. One important feature of this sensor is that the fluid does not contact any of the electronics, easing tube lumen sterilization procedures. Three types of bluff bodies were studied: two blades (with and without additional mass), and one cylinder. The experimental procedure consisted of establishing six different air flows and then capturing the accelerometer response in all of its three axes. Each of the collected signals from the accelerometer was divided in 24 parts, and these parts where analyzed through statistics; finally the mean response of the sensor was plotted. Best results were found in the accelerometer axis parallel to the air flow. In the blade tests, the RMS value of the AC component was proportional to the air flow, with linearity and correlation varying, respectively, from 19% and R2 = 0.99058 for the blade without mass, to 8.4% and R2 = 0.9741 for the blade with additional mass. It was observed that the mass addition reduced in a meaningful way the response variances. Yet the viscous force (DC value) did not respond in a monotonic way with the increase of air flow. On the other hand, the viscous force was the most expressive regarding the experiments with the cylinder (linearity of 0.17% and R2 = 0.96347), but the RMS value did not respond in a monotonic way. Finally, although further studies are needed to prove that the proposed sensor is efficient to be used in spirometry equipment, this study demonstrates that this sensor responds proportionally to the flow input, within (0 to 14 l/s) and without (up to 21 l/s) the spirometer operation range, with high correlation and linearity, as well as varying responses, given different inputs (flow), as verified by ANOVA test (p < 10-15). / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
6

Teoria de sistemas vibratorios aporticados não-lineares e não-ideais

Palacios Felix, Jorge Luis 03 August 2018 (has links)
Orientadores : Jose Manoel Balthazar, João Maurício Rosário / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T02:53:26Z (GMT). No. of bitstreams: 1 PalaciosFelix_JorgeLuis_D.pdf: 10005676 bytes, checksum: 18891d1bfc654d2a094a3bbd0b7857aa (MD5) Previous issue date: 2002 / Resumo: Apresenta-se o estudo do comportamento dinâmico não linear de um pórtico plano, excitado por uma fonte não ideal - um motor elétrico de corrente contínua, desbalanceado e de potência limitada. Toma-se, um problema cujo modelo matemático representa um sistema simplificado (com característica do motor em regime estacionário) e completo (considera-se a equação elétrica do motor). Adota-se a formulação Lagrangeana para gerar as equações de movimento, contendo termos não lineares até ordem cúbica. Tomam-se os valores dos parâmetros, tais que se observa à existência de ressonância interna 1 :2. A solução numérica é obtida através da utilização do método de Runge-Kutta com passo variável do programa MATLAB@. Os resultados numéricos e analíticos mostram boa correlação entre si, além de apresentarem alguns dos fenômenos associados, observados, como o efeito Sommerfeld. Outros fenômenos, devidos ao comportamento geometricamente não linear da estrutura, são também detectados, tais como saturação modal, a transferência de energia entre os modos e, além destes, é detectado a autosincronização entre dois motores apoiados em uma estrutura aporticada. A implementação e desempenho da técnica de controle por saturação para a supressão de vibrações de um sistema ideal e não ideal é estudada numericamente via SIMULINK@ / Abstract: This work concerns the computational and analytical study of the non-linear dynamic behavior of a portal frame, excited by a non-ideal source - an unbalanced direct current electric motor of limited power. A problem whose mathematical model represents a simplified system (the characteristic of the motor in stationary state) and complete (the electric equation of the motor is considered). Lagrange formularization for deducing the equations of motion, up to cubic nonlinear terms is followed. The values of the parameters are chosen to have one-to-two internal Resonance. The numerical solution is obtained through the use of the method of Runge-Kutta with variable step length by MATLAB@. The numerical and analytical results show good correlation, besides presenting some of the phenomena associated, observed, such as the Sommerfeld effect. Other phenomena, due to the geometric non-linear behavior of the structure, are also detected, such as modal saturation and energy transference between the modes. The self-synchronization phenomenon is a1so studied when two DC motors are considered. The implementation and performance of the saturation control for the suppression of vibrations of an ideal and non-ideal system is numerical studied by SIMULINK@ / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
7

Dinamica não-linear de um rotor não-ideal / Nonlinear dynamics of nonideal rotor

Rafikova, Elvira 21 February 2006 (has links)
Orientador: Jose Manoel Balthazar, Helder Anibal Hermini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-07T00:18:42Z (GMT). No. of bitstreams: 1 Rafikova_Elvira_M.pdf: 3918519 bytes, checksum: 739b1ab8bbabb497b9c71ffc87975974 (MD5) Previous issue date: 2006 / Resumo: Esse trabalho investiga um sistema dinâmico não- ideal que pertence a uma classe especial dos sistemas dinâmicos. O objeto de estudo desse trabalho é um rotor que consiste de um disco preso a uma barra elástica e excitado por uma fonte de energia de potência limitada. O sistema se desloca transversalmente e verticalmente além de possuir uma coordenada de rotação. Um estudo numérico do problema é realizado para investigar a dinâmica não-linear do sistema. Simulações numéricas tais como: diagramas de espaço de fase, curvas de resposta em freqüência, diagramas de bifurcação e expoentes de Lyapunov mostram uma forte influência da fonte de energia na resposta do sistema e revelam oscilações regulares e irregulares. Além disso, o efeito Sommerfeld é observado, assim como o salto na resposta em freqüência quando o parâmetro de controle do motor é variado. Finalmente comprova-se que os regimes irregulares presentes no movimento do sistema tem uma natureza caótica / Abstract: This work investigates a non- ideal dynamic system that is a special group of dynamics systems. The object studied in this work is a rotor composed of an elastic shaft carrying a disc which is excited by a limited power supply. The system has tranversal and vertical displacement and a coordinate of rotation of the disco A numerical study is done here in order to investigate the non-linear dynamics of the system. Numerical simulations such as: space-state diagrams, frequency response diagrams, bifurcations diagrams and Lyapunov exponent show the strong influence of the energy source on system response, and reveal regular and irregular motions. Besides, Sommerfeld effect is observed, as well as the jump in system response, when a control parameter of the energy source is varied. Futhermore, it is shown that the irregular regimes that occur in the system's motion are of chaotic nature / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
8

Vibrações não lineares e não ideais de um sistema de dois graus de liberdade

Guilherme, Karen de Lolo 03 August 2018 (has links)
Orientadores : Jose Manoel Balthazar, Paulo Roberto G. Kurka / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T22:10:26Z (GMT). No. of bitstreams: 1 Guilherme_KarendeLolo_M.pdf: 1561806 bytes, checksum: bd2a262ba245e5c1a8378de074061666 (MD5) Previous issue date: 2004 / Mestrado

Page generated in 0.0888 seconds