Orientador: Vivaldo Silveira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-19T16:38:58Z (GMT). No. of bitstreams: 1
Freitas_SamuelScarassatti_M.pdf: 3413897 bytes, checksum: 5e01dabc6101fefebe4dd9a0e9e103c1 (MD5)
Previous issue date: 2012 / Resumo: Dentro da indústria, os equipamentos de refrigeração ocupam um destacado papel no que se refere ao consumo de energia elétrica. A tarifação deste insumo vem sofrendo freqüentes reajustes, na medida em que sua demanda cresce e atende as necessidades econômicas do país. Os sistemas de termoacumulação representam uma alternativa para a economia do consumo energético nos períodos de maior tarifação, o que tende a atenuar os gastos com a energia elétrica. Neste trabalho, foi proposta a construção de um sistema de termoacumulação, com o objetivo de comparar esta técnica com um sistema tradicional de expansão seca em termos de consumo e demanda energética. O estudo envolveu a montagem da derivação da linha de refrigeração, a partir de um chiller, até o evaporador de uma câmara frigorífica, onde foram instalados sensores de temperatura, pressão e vazão, permitindo a avaliação das condições do processo por expansão seca. Em paralelo, foi montada uma linha de escoamento para o fluido refrigerante secundário que interligou um circuito onde o fluido é resfriado pelo sistema de refrigeração, termoacumulado em um tanque e bombeado ate um trocador de calor instalado dentro da câmara, onde é utilizado para resfriar o ambiente. A aplicação da termoacumulação objetivou alcançar as mesmas condições da câmara, mantidas pela expansão seca, com a posterior avaliação do consumo energético apresentado pelos dois sistemas. Foram instalados sensores de temperatura na linha de refrigerante secundário e também dentro da câmara. O consumo de potência da bomba e do compressor foram registrados e utilizados na comparação energética dos sistemas. A avaliação qualitativa englobou o cálculo da carga térmica empírica da câmara, bem como o registro das condições de funcionamento dos sistemas durante a expansão seca e a refrigeração do circuito secundário. A comparação dos sistemas frente ao consumo energético indicou uma economia superior a 42% na utilização da termoacumulação durante o período de ponta em comparação com o sistema de expansão seca. A aplicação da termoacumulação manteve a temperatura do interior da câmara estável durante as três horas em que o compressor permaneceu desligado, mostrando ser uma técnica de grande economia energética quando comparada com o sistema secundário sem termoacumulação, apresentando uma economia de 26% nos gastos em função deste período / Abstract: In the industry, refrigeration equipments possess a detached function in electric energy consumption. The price of this input has been frequently adjusted. In the same way that the demand grows and fills the economic needs of the country. the cool storage systems represent an alternative for save power consumption during periods of peak pricing, tending to decrease spending on energy consumption. In this paper, it was proposed the construction of a system for cool storage, in order to compare that technique with a traditional dry-expansion system, in terms of consumption and energy. The study involved the derivation of the assembly line cooling from a chiller evaporator until a cold chamber, on the line, temperature, pressure and flow sensors, were installed allowing the evaluation of process conditions for dry expansion . In parallel, a line was built, through which the refrigerant is pumped through a secondary circuit where it is cooled by the cooling system, stored in a tank at low temperature, and pumped to a heat exchanger installed inside the chamber where it is used to cool the environment. . The cool storage application had as an objective maintains the room conditions as the same in dry expansion, With the subsequent evaluation of the energy consumption of each system. Temperature sensors were installed in the secondary coolant line and also inside the chamber. The power consumption of the pump and compressor were recorded and used to comparing the two systems. The evaluation, has included the empirical calculation of the heat load for the cold chamber and the recording data of the system operating conditions during the dry-expansion and the cooling by the secondary circuit The comparison between the systems has indicated energy savings of more than 42% in the use of the cool stored system during the peak period. The application of cool storage kept the temperature inside the camera steady during the three hours when the compressor was off, proving to be a technique of great energy savings when compared to the secondary system without termoacumulação, showing a 26% saving in costs due this period / Mestrado / Engenharia de Alimentos / Mestre em Engenharia de Alimentos
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/255770 |
Date | 03 February 2012 |
Creators | Freitas, Samuel Scarassatti |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Silveira Júnior, Vivaldo, 1962-, Junior, Vivaldo Silveira, Lima, Carlos Umberto da Silva, Jordan, Rodrigo Aparecido |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia de Alimentos, Programa de Pós-Graduação em Engenharia de Alimentos |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 106 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0077 seconds