Return to search

Valor da ecocardiografia tridimensional em tempo real em portadores de cardiomiopatia hipertrófica. Comparação com a ecocardiografia bidimensional e a ressonância magnética cardiovascular / Value of real-time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy. Comparison with twodimensional echocardiography and magnetic resonance imaging

INTRODUÇÃO: A ecocardiografia tridimensional em tempo real (E3DTR) vem provando sua acurácia para quantificar os volumes do ventrículo esquerdo (VE), fração de ejeção (FEVE) e massa em pacientes com cardiomiopatia. Na cardiomiopatia hipertrófica (CMH), onde a morfologia ventricular pode estar muito alterada, a análise das estruturas cardíacas é fundamental para indicação da terapêutica ideal. A ressonância magnética cardiovascular (RMC) é um método superior na análise segmentar do VE em comparação a ecocardiografia bidimensional (E2D), mas com alta complexidade e existente em poucos centros diagnósticos, com contraindicações e limitações para a sua realização. MÉTODOS: Estudo transversal, comparativo, duplo cego, em 20 portadores de CMH, com E2D, E3DTR e RMC realizados com intervalo máximo de 06 meses e armazenados em formato digital. A espessura das paredes, volumes, função sistólica e massa ventricular esquerda foram analisados pelos métodos ecocardiográficos e pela RMC, assim como o movimento anterior sistólico da valva mitral, o índice geométrico do VE e o índice sistólico de dissincronia do VE. ANÁLISE ESTATÍSTICA: Análise estatística pelo coeficiente de concordância de Lin, correlação linear de Pearson e modelo de Bland-Altman. RESULTADOS: Foi obtida exeqüibilidade elevada acima de 94%, dependente do parâmetro avaliado. Concordância satisfatória e forte correlação linear evidenciada para a análise segmentar (Rc>0.84 e r>0.85; p<0.0001) observada para os métodos ecocardiográficos comparados à RMC, com concordância excelente entre os métodos ecocardiográficos (Rc=0,92 e r=0,92, p<0,0001). Concordância satisfatória e forte correlação linear para a fração de ejeção do VE (Rc=0.83 e r=0.93; p<0.0001) pela E3DTR comparada à RMC. Concordância excelente e forte correlação linear para o VDFVE e VSFVE pela E3DTR comparada à RMC e pela E2D comparada à E3DTR (Rc>0.90 and r>0.95; p<0.0001), assim como para a massa do VE, para os métodos E3DTR e RMC (Rc=0.96 e r=0.97; p<0.0001). Evidenciada maior exeqüibilidade da análise do MAS pela E3DTR. O índice geométrico do VE foi >0,15mmxm²xml-1 para todos os métodos. Observada correlação negativa entre o índice de dissincronia do VE e o percentual de fibrose miocárdica, sem significância estatística. CONCLUSÕES: A E3DTR é precisa e superior à E2D na avaliação da distribuição da hipertrofia miocárdica, quantificação dos volumes, função e massa ventricular esquerda em pacientes com CMH quando comparada à RMC, e parece ser superior na análise do MAS, pela melhor visão espacial da valva mitral.Todas as medidas do índice geométrico do ventrículo esquerdo estavam acima de 0,15mmxm²xml-1, compatível com CMH. Não foi identificada correlação entre o índice sistólico de dissincronia ventricular esquerda e a fibrose miocárdica. / INTRODUCTION: Real-time three-dimensional echocardiography (RT3D) has been demonstrated an accurate technique for the quantification of left ventricular (LV) volumes, ejection fraction (LVEF), and mass. In patients with hypertrophic cardiomyopathy (HCM), in which alterations of ventricular morphology are common, cardiac structural analysis is of utmost importance for guiding adequate therapy. Although magnetic resonance imaging (MRI) seems to have better definition for segmental analysis than two-dimensional echocardiography, (2D-E), it is considered a complex test with low availability and some limitations for use. METHODS: Comparative and double-blinded study in 20 patients with HCM. All patients underwent 2DE, RT3D and MRI within maximal interval of 6 months. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, systolic function, LV mass, systolic anterior motion of mitral valve, LV geometric index and LV dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. RESULTS: Feasibility for measurements by MRI and echocardiography was 94%. There was good agreement and linear correlation between segmental analysis by echocardiography and MRI (Rc>0.84 and r>0.85; p<0.0001) and excellent correlation between 2DE and RT3DE (Rc=0.92 and r=0.92; p<0.0001). We also observed good agreement and linear correlation between RT3DE and MRI for ejection fraction (Rc=0.83 and r=0.93; p<0.0001) and excellent agreement and linear correlation between RT3DE and MRI for LV end diastolic volume and LV end systolic volume determinations (Rc>0.90 and r>0.95; p<0.0001) and mass (Rc=0.96 and r=0.97; p<0.0001). The feasibility for systolic anterior motion of mitral valve was higher by RT3DE (91%) than 2DE (64%). LV geometric index was >0.15 mmxm²xml-1 for all techniques. There was no correlation between LV dyssynchrony index and the percentage of myocardial fibrosis. CONCLUSIONS: RT3D is an accurate technique with superior performance than 2DE for the evaluation of myocardial hypertrophy localization, LV volume and functional determination as well as for LV mass assessment in patients with HCM in comparison with MRI. In addition, it seems to be superior for the analysis of systolic anterior motion due to its better spatial view of mitral valve. All measurements of LV geometric index were above the value of 0.15 mmxm²xml-1, and such findings are compatible with HCM. No correlation between LV dyssynchrony index by RT3D and the percentage of myocardial fibrosis determined by MRI was identified.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-13022008-083314
Date30 November 2007
CreatorsLeticia Santos Bicudo
ContributorsWilson Mathias Júnior, Henry Abensur, Ibraim Masciarelli Francisco Pinto, Andre Schmidt, Carlos Vicente Serrano Junior
PublisherUniversidade de São Paulo, Cardiologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds