Avaliação Estrutural e Funcional do Átrio Esquerdo na Cardiomiopatia Chagásica comparada à Cardiomiopatia Dilatada Idiopática. Um estudo com Ecocardiografia Tridimensional Em Tempo Real / Structural and functional evaluation of the left atrium in the chagasic cardiomiopathy compared to idiophatic dilated cardiomiopathy. A study with real time three-dimensional echocardiography

Mancuso, Frederico Jose Neves [UNIFESP] 25 May 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-25. Added 1 bitstream(s) on 2015-08-11T03:26:04Z : No. of bitstreams: 1 Publico-12568.pdf: 728430 bytes, checksum: c5ba742868ac39fa9a8eaa7f300d7f89 (MD5) / Introdução: Embora existam evidências anatomopatológicas de comprometimento atrial na cardiomiopatia chagásica (CMPC), o impacto sobre a função do átrio esquerdo (AE) ainda não é conhecido. O objetivo deste estudo foi avaliar os volumes e a função do AE em pacientes com CMPC pela ecocardiografia tridimensional em tempo real (E3DTR) e compará-los com pacientes com cardiomiopatia dilatada idiopática (CMPD), correlacionando os achados com variáveis clínicas e ecocardiográficas. Métodos: Trinta pacientes com CMPC, 30 com CMPD e 20 indivíduos normais que formaram o grupo controle (GC), foram estudados. Com a E3DTR, medimos os volumes máximo (VolmaxAE), mínimo (VolminAE) e pré onda P do ECG (VolpreAAE) do AE e calculamos a fração de esvaziamento total (FETAE) e ativa (FEAAE) do AE. Outras variáveis ecocardiográficas, bem como variáveis clínicas também foram analisadas nos grupos. Os resultados foram comparados por testes estatísticos (ANOVA) ao nível de significância de p<0,05. Correlação de Pearson foi utilizada entre variáveis contínuas ecocardiográficas e clínicas. Por meio de análise multivariada por regressão linear, identificamos as variáveis independentemente relacionadas ao aumento do VolmaxAE e à piora da função atrial ativa no grupo CMPC. Resultados: A fração de ejeção do ventrículo esquerdo e a insuficiência mitral foram semelhantes nos grupos CMPC e CMPD. O VolmaxAE/m2 foi maior na CMPC do que na CMPD (76,9 ± 21,9 ml vs. 59,1 ± 26,0 ml; p<0,01), ambos significativamente maiores do que no GC (p<0,01). A FETAE foi menor nos pacientes com CMPC do que nos pacientes com CMPD (30,5 ± 10,5% vs. 39,9 ± 11,8%; p<0,01), e ambas foram menores do que no GC (p=0,01). A FEAAE também foi menor no grupo CMPC do que no grupo CMPD (21,9 ± 9,5% vs. 28,2 ± 11,1%; p<0,01), ambas menores do que no GC (p=0,01). A relação E/e´ foi maior no grupo CMPC do que no grupo CMPD (21 ± 10 vs. 15±6; p<0,01), e ambos os grupos apresentaram relações maiores do que o GC (p<0,01). No modelo de regressão múltipla, a relação E/e´ e a insuficiência mitral foram as variáveis independentemente associadas ao aumento do VolmaxAE, enquanto que a relação E/e´ foi a única variável independentemente associada à piora da FEAAE. Conclusão: O VolmaxAE é maior na CMPC do que na CMPD, assim como a função ativa do AE é mais comprometida na CMPC do que na CMPD. Estes achados indicam um comprometimento miocárdico maior e mais extenso na cardiomiopatia chagásica, provavelmente relacionado ao aumento da pressão diastólica do ventrículo esquerdo e à miopatia atrial. / Background: Although there is anatomopathological evidence of atrial involvement in Chagas cardiomyopathy (CCM), the impact in left atrial (LA) function is unknown. The aim of this study was to evaluate LA volumes and function in CCM patients with real-time three-dimensional echocardiography (RT3DE) and to compare it with idiopathic dilated cardiomyopathy (DCM) patients, correlating the findings with clinical and echocardiographic variables. Methods: Thirty patients with CCM, 30 with DCM, and 20 normal subjects used as the control group (CG) were studied. With RT3DE, we measured LA maximum (maxLAV), minimum and pre-atrial contraction volumes and calculated total (TLAEF) and active (ALAEF) LA emptying fraction. Clinical variables and other echocardiographic variables were evaluated in the patients. The data were compared with statistical tests (ANOVA); significant if p . 0,05. The Pearson correlation coefficient was used between clinical and echocardiographic continuous variables. With multiple regression model we identified the determinants of increasing maxLAV e of the ALAEF worsening, in CCM patients. Results: Left ventricular ejection fraction and mitral regurgitation were similar in both groups. MaxLAV/m2 was larger in CCM than in DCM (76.9 }21.9 ml vs. 59.1 }26.0 ml; p<0.01), and both were significantly larger than in the CG (p<0.01). TLAEF was lower in CCM patients than in DCM (30 } 10% vs. 40 } 12%; p<0.01), and both were lower than in the CG (p=0.01). ALAEF was also lower in CCM than in DCM (22 } 0.09% vs. 28 } 11%; p<0.01), and both were lower than in the CG (p=0.01). The E/e f ratio was higher in CCM than in DCM (21 }10 vs. 15 }6; p<0.01), and both were greater than in the CG (p<0.01). In a multiple regression model, the E/e L ratio and the mitral regurgitation were predictors of a increasing in MaxLAV, meanwhile the E/e L ratio was the only independent predictor of a worsening ALAEF. Conclusion: The MaxLAV were greater in CCM than in DCM and the LA function is more compromised in CCM than in DCM. This finding indicates a more diffuse and severe myocardial impairment in Chagas disease that is probably related to increased left ventricular filling pressures and atrial myopathy. / TEDE / BV UNIFESP: Teses e dissertações
2

Avaliação da dissincronia ventricular mecânica pela ecocardiografia tridimensional em pacientes portadores de bloqueio atrioventricular total congênito e marcapasso / Left ventricular dyssynchrony evaluated by three-dimensional echocardiography in patients with congenital complete atrioventricular block and long-term pacing

Guerra, Vitor Coimbra 09 September 2010 (has links)
A disfunção ventricular esquerda (VE) é o principal determinante de mau prognóstico nos pacientes com bloqueio atrioventricular completo congênito (BAVTC) e marcapasso (MP). A dissincronia mecânica do VE pode desempenhar um papel importante no desenvolvimento da disfunção ventricular. Como o uso do MP é um fator de risco para dissincronia, nosso(s) objetivo(s) foram: (1) avaliar a dissincronia do VE pelo ecocardiograma tridimensional (3D) em tempo real e comparar com os parâmetros de dissincronia pelo Doppler tecidual ; (2) verificar a possível correlação entre o local do estímulo e o segmento ativado tardiamente; (3) correlacionar o tempo de marcapasso e a presença de dissincronia e remodelamento ventricular. Avaliamos 50 pacientes com BAVTC e MP através do ecocardiograma bidimensional (2D), Doppler tecidual e ecocardiograma tridimensional. Dados clínicos e anteriores ao implante do MP foram revistos pelos prontuários. Houve 12 (23,5%) pacientes com dissincronia pelo 3D e 14 (28%) pelo Doppler tecidual. Em 16 (32%) e 20 (40%) havia disfunção ventricular esquerda pelos 2D e 3D respectivamente. O remodelamento ventricular ocorreu em 50% dos pacientes. Houve uma excelente correlação entre o Doppler tecidual e o 3D para diagnóstico de dissincronia (kappa = 0,735, p <0,001). A fração de ejeção do VE (FEVE) correlacionou-se negativamente com a dissincronia pelo eco 3D (r= -0,58, p = 0,000001). A duração do ciclo cardíaco medida pelo intervalo RR teve também uma significante correlação negativa com o índice de dissincronia pelo 3D (r=-0,74, p=0,0011). O remodelamento do VE pelo Eco 3D (índices de esfericidade e conicidade) teve uma boa correlação com a disfunção do VE (p = 0,005 e 0,003 respectivamente). O tempo de marcapasso, a idade do implante e o local do eletrodo não se correlacionaram com a dissincronia. Comparando os pacientes com BAVTC e MP menores que 18 anos com um grupo controle de crianças normais, houve uma significante diferença em relação aos volumes do VE, índices de dissincronia, esfericidade e conicidade. Em conclusão, neste estudo transversal de pacientes com BAVTC e uso crônico de MP, o ecocardiograma tridimensional teve uma excelente correlação com o Doppler tecidual no diagnóstico de dissincronia mecânica. A posição do eletrodo não foi preditora do segmento ativado tardiamente. O tempo de MP não se correlacionou com a presença de dissincronia e disfunção do VE. Houve uma boa correlação entre a dissincronia, remodelamento e disfunção do VE / The left ventricle (LV) dysfunction is the major reason for poor outcome in patients with congenital complete atrioventricular block (CCAVB) and pacemaker (PM). The LV mechanical dyssynchrony may play a significant role in the development of LV dysfunction in this population. As the long-term pacing is a potential risk factor for dyssynchrony, we sought to: (1) evaluate by real time three-dimensional echocardiography (RT3DE) the LV dyssynchrony and compare with Tissue Doppler (TDI) parameters; (2) verify the potential correlation between the electrode location and the latest segment activated; (3) correlate the time of pacing and LV dyssynchrony and LV remodeling. Two-dimensional (2D), TDI and RT3DE were performed in 50 patients with CCAVB and PM (mean age of 21,4 years DP 13,4). Clinical data were reviewed. Twelve (23,5%) had LV dyssynchrony by RT3DE and 14 (28%) by Tissue Doppler criteria. Sixteen (32%) and 20 (40%) had LV dysfunction by 2D and 3D, respectively. LV remodeling occurred in 50% of patients. There was an excellent correlation between RT3DE and TDI (Kappa = 0,735; p <0,001). The LV ejection fraction (LVEF) had a significant negative correlation with the dyssynchrony index by 3D (r = -0,58, p = 0,000001). The duration of the cardiac cycle measured by RR interval had a significant negative correlation with the LV dyssynchrony index by 3D (r = - 0,74, p = 0,0011). LV remodeling demonstrated by the sphericity and conic indexes had a good correlation with the presence of LV dysfunction (p = 0,005 and 0,003 respectively). The pacing time, the age at pacemaker implantation and the location of the electrode did not correlate with LV dyssynchrony. Patients bellow 18 years of age were significantly different in terms of LV dyssynchrony indexes, LV remodeling and LV volumes when compared with a control group with similar age and body surface area. In conclusion, in a cohort study of patients with CCAVB and long-term pacing, the RT3DE had an excellent correlation with TDI to evaluate LV dyssynchrony. The pacing site was not a predictor of the latest segment activation. The pacing time did not correlate with LV dyssynchrony and dysfunction. There was a correlation between the LV dyssynchrony and the presence of remodeling and dysfunction
3

Avaliação da dissincronia ventricular mecânica pela ecocardiografia tridimensional em pacientes portadores de bloqueio atrioventricular total congênito e marcapasso / Left ventricular dyssynchrony evaluated by three-dimensional echocardiography in patients with congenital complete atrioventricular block and long-term pacing

Vitor Coimbra Guerra 09 September 2010 (has links)
A disfunção ventricular esquerda (VE) é o principal determinante de mau prognóstico nos pacientes com bloqueio atrioventricular completo congênito (BAVTC) e marcapasso (MP). A dissincronia mecânica do VE pode desempenhar um papel importante no desenvolvimento da disfunção ventricular. Como o uso do MP é um fator de risco para dissincronia, nosso(s) objetivo(s) foram: (1) avaliar a dissincronia do VE pelo ecocardiograma tridimensional (3D) em tempo real e comparar com os parâmetros de dissincronia pelo Doppler tecidual ; (2) verificar a possível correlação entre o local do estímulo e o segmento ativado tardiamente; (3) correlacionar o tempo de marcapasso e a presença de dissincronia e remodelamento ventricular. Avaliamos 50 pacientes com BAVTC e MP através do ecocardiograma bidimensional (2D), Doppler tecidual e ecocardiograma tridimensional. Dados clínicos e anteriores ao implante do MP foram revistos pelos prontuários. Houve 12 (23,5%) pacientes com dissincronia pelo 3D e 14 (28%) pelo Doppler tecidual. Em 16 (32%) e 20 (40%) havia disfunção ventricular esquerda pelos 2D e 3D respectivamente. O remodelamento ventricular ocorreu em 50% dos pacientes. Houve uma excelente correlação entre o Doppler tecidual e o 3D para diagnóstico de dissincronia (kappa = 0,735, p <0,001). A fração de ejeção do VE (FEVE) correlacionou-se negativamente com a dissincronia pelo eco 3D (r= -0,58, p = 0,000001). A duração do ciclo cardíaco medida pelo intervalo RR teve também uma significante correlação negativa com o índice de dissincronia pelo 3D (r=-0,74, p=0,0011). O remodelamento do VE pelo Eco 3D (índices de esfericidade e conicidade) teve uma boa correlação com a disfunção do VE (p = 0,005 e 0,003 respectivamente). O tempo de marcapasso, a idade do implante e o local do eletrodo não se correlacionaram com a dissincronia. Comparando os pacientes com BAVTC e MP menores que 18 anos com um grupo controle de crianças normais, houve uma significante diferença em relação aos volumes do VE, índices de dissincronia, esfericidade e conicidade. Em conclusão, neste estudo transversal de pacientes com BAVTC e uso crônico de MP, o ecocardiograma tridimensional teve uma excelente correlação com o Doppler tecidual no diagnóstico de dissincronia mecânica. A posição do eletrodo não foi preditora do segmento ativado tardiamente. O tempo de MP não se correlacionou com a presença de dissincronia e disfunção do VE. Houve uma boa correlação entre a dissincronia, remodelamento e disfunção do VE / The left ventricle (LV) dysfunction is the major reason for poor outcome in patients with congenital complete atrioventricular block (CCAVB) and pacemaker (PM). The LV mechanical dyssynchrony may play a significant role in the development of LV dysfunction in this population. As the long-term pacing is a potential risk factor for dyssynchrony, we sought to: (1) evaluate by real time three-dimensional echocardiography (RT3DE) the LV dyssynchrony and compare with Tissue Doppler (TDI) parameters; (2) verify the potential correlation between the electrode location and the latest segment activated; (3) correlate the time of pacing and LV dyssynchrony and LV remodeling. Two-dimensional (2D), TDI and RT3DE were performed in 50 patients with CCAVB and PM (mean age of 21,4 years DP 13,4). Clinical data were reviewed. Twelve (23,5%) had LV dyssynchrony by RT3DE and 14 (28%) by Tissue Doppler criteria. Sixteen (32%) and 20 (40%) had LV dysfunction by 2D and 3D, respectively. LV remodeling occurred in 50% of patients. There was an excellent correlation between RT3DE and TDI (Kappa = 0,735; p <0,001). The LV ejection fraction (LVEF) had a significant negative correlation with the dyssynchrony index by 3D (r = -0,58, p = 0,000001). The duration of the cardiac cycle measured by RR interval had a significant negative correlation with the LV dyssynchrony index by 3D (r = - 0,74, p = 0,0011). LV remodeling demonstrated by the sphericity and conic indexes had a good correlation with the presence of LV dysfunction (p = 0,005 and 0,003 respectively). The pacing time, the age at pacemaker implantation and the location of the electrode did not correlate with LV dyssynchrony. Patients bellow 18 years of age were significantly different in terms of LV dyssynchrony indexes, LV remodeling and LV volumes when compared with a control group with similar age and body surface area. In conclusion, in a cohort study of patients with CCAVB and long-term pacing, the RT3DE had an excellent correlation with TDI to evaluate LV dyssynchrony. The pacing site was not a predictor of the latest segment activation. The pacing time did not correlate with LV dyssynchrony and dysfunction. There was a correlation between the LV dyssynchrony and the presence of remodeling and dysfunction
4

Papel do ecocardiograma transesofágico tridimensional na ótima seleção do dispositivo para o tratamento percutâneo da comunicação interatrial tipo ostium secundum / Role of three-dimensional transesophageal echocardiography in optimal device selection for percutaneous treatment of the ostium secundum atrial septal defect

Arrieta, Santiago Raul 19 May 2015 (has links)
INTRODUCAO: A comunicação interatrial tipo \"ostium secundum\" é um defeito cardíaco congênito caracterizado pela deficiência parcial ou total da lâmina da fossa oval, também chamada de septo primo. Corresponde a 10 a 12% do total de cardiopatias congênitas, sendo a mais frequente na idade adulta. Atualmente a oclusão percutânea é o método terapêutico de escolha em defeitos com características anatômicas favoráveis para o implante de próteses na maioria dos grandes centros mundiais. A ecocardiografia transesofágica bidimensional com mapeamento de fluxo em cores é considerada a ferramenta padrão-ouro para a avaliação anatômica e monitoração durante do procedimento, sendo crucial para a ótima seleção do dispositivo. Neste sentido, um balão medidor é introduzido e insuflado através do defeito de forma a ocluí-lo temporariamente. A medida da cintura que se visualiza no balão (diâmetro estirado) é utilizada como referência para a escolha do tamanho da prótese. Recentemente a ecocardiografia tridimensional transesofágica em tempo real tem sido utilizada neste tipo de intervenção percutânea. Neste estudo avaliamos o papel da mesma na ótima seleção do dispositivo levando-se em consideração as dimensões e a geometria do defeito e a espessura das bordas do septo interatrial. METODO: Estudo observacional, prospectivo, não randomizado, de único braço, de uma coorte de 33 pacientes adultos portadores de comunicação interatrial submetidos a fechamento percutâneo utilizando dispositivo de nitinol autocentrável (Cera ®, Lifetech Scientific, Shenzhen, China). Foram analisadas as medidas do maior e menor diâmetro do defeito, sua área e as medidas do diâmetro estirado com balão medidor obtidas por meio das duas modalidades ecocardiográficas. Os defeitos foram considerados como elípticos ou circulares segundo a sua geometria; as bordas ao redor da comunicação foram consideradas espessas (>2 mm) ou finas. O dispositivo selecionado foi igual ou ate 2 mm maior que o diâmetro estirado na ecocardiografia transesofágica bidimensional (padrão-ouro). Na tentativa de identificar uma variável que pudesse substituir o diâmetro estirado do balão para a ótima escolha do dispositivo uma série de correlações lineares foram realizadas. RESULTADOS: A idade e peso médio foram de 42,1 ± 14,9 anos e 66,0 ± 9,4kg, respectivamente; sendo 22 de sexo feminino. Não houve diferenças estatísticas entre os diâmetros maior e menor ou no diâmetro estirado dos defeitos determinados por ambas as modalidades ecocardiográficas. A correlação entre as medidas obtidas com ambos os métodos foi ótima (r > 0,90). O maior diâmetro do defeito, obtido à ecoardiografia transesofágica tridimensional, foi a variável com melhor correlação com o tamanho do dispositivo selecionado no grupo como um todo (r= 0,89) e, especialmente, nos subgrupos com geometria elíptica (r= 0,96) e com bordas espessas ao redor do defeito (r= 0,96). CONCLUSÃO: Neste estudo em adultos com comunicações interatriais tipo ostium secundum submetidos à oclusão percutânea com a prótese Cera ®, a ótima seleção do dispositivo pôde ser realizada utilizando-se apenas a maior medida do defeito obtida na ecocardiografia transesofágica tridimensional em tempo real, especialmente nos pacientes com defeitos elípticos e com bordas espessas. / INTRODUCTION: The ostium secundum atrial septal defect is a congenital heart disease characterized by partial or total deficiency of the fossa ovalis, also known as the septum primum. It corresponds to 10-12% of all congenital heart defects, being the most frequently found in adulthood. Currently, percutaneous closure is the therapeutic method of choice for defects with suitable anatomic features for device implantation in most centers in the world. Bi-dimensional transesophageal echocardiography with color flow mapping is considered the gold-standard tool for anatomic assessment and procedural monitoring, being crucial for optimal device selection. In this regard, a sizing balloon is introduced and inflated across the defect with temporary occlusion. The waist measurement seen on the balloon (stretched diameter) is used as a reference for selection of device size. Recently, real time three-dimensional transesophageal echocardiography has been utilized in this type of percutaneous intervention. In this study we assessed the role of this modality in optimal device selection taking into consideration the dimensions and the geometry of the defect and the thickness of the interatrial septum rims. METHODS: Observational, prospective, non-randomized, single-arm study of a cohort of 33 adults with atrial septal defects submitted to percutaneous closure using a self-centered nitinol device (Cera (TM), Lifetech Scientific, Shenzhen, China). The largest and the smallest diameter of the defect, its area and the measurements of the stretched diameter of the sizing balloon were assessed by both echocardiographic modalities. The defects were considered as elliptical or circular according to their geometry; the rims surrounding the defect were considered thick (> 2 mm) or thin. The selected device was equal to or 2 mm larger than the stretched diameter on bi-dimensional transesophageal echocardiography (gold-standard). In an attempt to identify a variable that could replace the stretched balloon diameter, a series of linear correlations were performed. RESULTS: The mean age and weight were 42.1 ± 14.9 years and 66.0 ± 9.4 kgs, respectively; being 22 of the female gender. There were no statistical differences between the largest and smallest diameters of the defects and the stretched diameters determined by both echocardiographic modalities. The correlation between the measurements obtained by both methods was excellent (r > 0.90). The largest defect diameter obtained by three-dimensional transesophageal echocardiography was the variable that showed the best correlation with the selected device size in the entire group (r= 0.89), especially in the subgroups with elliptical geometry (r= 0.96) and with thick rims surrounding the defect (r=0.96). CONCLUSIONS: In this study in adults with ostium secundum atrial septal defects submitted to percutaneous occlusion with the Cera (TM) device, optimal device selection could be performed using solely the largest diameter of the defect obtained by real time three-dimensional transesophageal echocardiography, especially in patients with elliptical defects and thick rims.
5

Papel do ecocardiograma transesofágico tridimensional na ótima seleção do dispositivo para o tratamento percutâneo da comunicação interatrial tipo ostium secundum / Role of three-dimensional transesophageal echocardiography in optimal device selection for percutaneous treatment of the ostium secundum atrial septal defect

Santiago Raul Arrieta 19 May 2015 (has links)
INTRODUCAO: A comunicação interatrial tipo \"ostium secundum\" é um defeito cardíaco congênito caracterizado pela deficiência parcial ou total da lâmina da fossa oval, também chamada de septo primo. Corresponde a 10 a 12% do total de cardiopatias congênitas, sendo a mais frequente na idade adulta. Atualmente a oclusão percutânea é o método terapêutico de escolha em defeitos com características anatômicas favoráveis para o implante de próteses na maioria dos grandes centros mundiais. A ecocardiografia transesofágica bidimensional com mapeamento de fluxo em cores é considerada a ferramenta padrão-ouro para a avaliação anatômica e monitoração durante do procedimento, sendo crucial para a ótima seleção do dispositivo. Neste sentido, um balão medidor é introduzido e insuflado através do defeito de forma a ocluí-lo temporariamente. A medida da cintura que se visualiza no balão (diâmetro estirado) é utilizada como referência para a escolha do tamanho da prótese. Recentemente a ecocardiografia tridimensional transesofágica em tempo real tem sido utilizada neste tipo de intervenção percutânea. Neste estudo avaliamos o papel da mesma na ótima seleção do dispositivo levando-se em consideração as dimensões e a geometria do defeito e a espessura das bordas do septo interatrial. METODO: Estudo observacional, prospectivo, não randomizado, de único braço, de uma coorte de 33 pacientes adultos portadores de comunicação interatrial submetidos a fechamento percutâneo utilizando dispositivo de nitinol autocentrável (Cera ®, Lifetech Scientific, Shenzhen, China). Foram analisadas as medidas do maior e menor diâmetro do defeito, sua área e as medidas do diâmetro estirado com balão medidor obtidas por meio das duas modalidades ecocardiográficas. Os defeitos foram considerados como elípticos ou circulares segundo a sua geometria; as bordas ao redor da comunicação foram consideradas espessas (>2 mm) ou finas. O dispositivo selecionado foi igual ou ate 2 mm maior que o diâmetro estirado na ecocardiografia transesofágica bidimensional (padrão-ouro). Na tentativa de identificar uma variável que pudesse substituir o diâmetro estirado do balão para a ótima escolha do dispositivo uma série de correlações lineares foram realizadas. RESULTADOS: A idade e peso médio foram de 42,1 ± 14,9 anos e 66,0 ± 9,4kg, respectivamente; sendo 22 de sexo feminino. Não houve diferenças estatísticas entre os diâmetros maior e menor ou no diâmetro estirado dos defeitos determinados por ambas as modalidades ecocardiográficas. A correlação entre as medidas obtidas com ambos os métodos foi ótima (r > 0,90). O maior diâmetro do defeito, obtido à ecoardiografia transesofágica tridimensional, foi a variável com melhor correlação com o tamanho do dispositivo selecionado no grupo como um todo (r= 0,89) e, especialmente, nos subgrupos com geometria elíptica (r= 0,96) e com bordas espessas ao redor do defeito (r= 0,96). CONCLUSÃO: Neste estudo em adultos com comunicações interatriais tipo ostium secundum submetidos à oclusão percutânea com a prótese Cera ®, a ótima seleção do dispositivo pôde ser realizada utilizando-se apenas a maior medida do defeito obtida na ecocardiografia transesofágica tridimensional em tempo real, especialmente nos pacientes com defeitos elípticos e com bordas espessas. / INTRODUCTION: The ostium secundum atrial septal defect is a congenital heart disease characterized by partial or total deficiency of the fossa ovalis, also known as the septum primum. It corresponds to 10-12% of all congenital heart defects, being the most frequently found in adulthood. Currently, percutaneous closure is the therapeutic method of choice for defects with suitable anatomic features for device implantation in most centers in the world. Bi-dimensional transesophageal echocardiography with color flow mapping is considered the gold-standard tool for anatomic assessment and procedural monitoring, being crucial for optimal device selection. In this regard, a sizing balloon is introduced and inflated across the defect with temporary occlusion. The waist measurement seen on the balloon (stretched diameter) is used as a reference for selection of device size. Recently, real time three-dimensional transesophageal echocardiography has been utilized in this type of percutaneous intervention. In this study we assessed the role of this modality in optimal device selection taking into consideration the dimensions and the geometry of the defect and the thickness of the interatrial septum rims. METHODS: Observational, prospective, non-randomized, single-arm study of a cohort of 33 adults with atrial septal defects submitted to percutaneous closure using a self-centered nitinol device (Cera (TM), Lifetech Scientific, Shenzhen, China). The largest and the smallest diameter of the defect, its area and the measurements of the stretched diameter of the sizing balloon were assessed by both echocardiographic modalities. The defects were considered as elliptical or circular according to their geometry; the rims surrounding the defect were considered thick (> 2 mm) or thin. The selected device was equal to or 2 mm larger than the stretched diameter on bi-dimensional transesophageal echocardiography (gold-standard). In an attempt to identify a variable that could replace the stretched balloon diameter, a series of linear correlations were performed. RESULTS: The mean age and weight were 42.1 ± 14.9 years and 66.0 ± 9.4 kgs, respectively; being 22 of the female gender. There were no statistical differences between the largest and smallest diameters of the defects and the stretched diameters determined by both echocardiographic modalities. The correlation between the measurements obtained by both methods was excellent (r > 0.90). The largest defect diameter obtained by three-dimensional transesophageal echocardiography was the variable that showed the best correlation with the selected device size in the entire group (r= 0.89), especially in the subgroups with elliptical geometry (r= 0.96) and with thick rims surrounding the defect (r=0.96). CONCLUSIONS: In this study in adults with ostium secundum atrial septal defects submitted to percutaneous occlusion with the Cera (TM) device, optimal device selection could be performed using solely the largest diameter of the defect obtained by real time three-dimensional transesophageal echocardiography, especially in patients with elliptical defects and thick rims.
6

Valor da ecocardiografia tridimensional em tempo real em portadores de cardiomiopatia hipertrófica. Comparação com a ecocardiografia bidimensional e a ressonância magnética cardiovascular / Value of real-time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy. Comparison with twodimensional echocardiography and magnetic resonance imaging

Bicudo, Leticia Santos 30 November 2007 (has links)
INTRODUÇÃO: A ecocardiografia tridimensional em tempo real (E3DTR) vem provando sua acurácia para quantificar os volumes do ventrículo esquerdo (VE), fração de ejeção (FEVE) e massa em pacientes com cardiomiopatia. Na cardiomiopatia hipertrófica (CMH), onde a morfologia ventricular pode estar muito alterada, a análise das estruturas cardíacas é fundamental para indicação da terapêutica ideal. A ressonância magnética cardiovascular (RMC) é um método superior na análise segmentar do VE em comparação a ecocardiografia bidimensional (E2D), mas com alta complexidade e existente em poucos centros diagnósticos, com contraindicações e limitações para a sua realização. MÉTODOS: Estudo transversal, comparativo, duplo cego, em 20 portadores de CMH, com E2D, E3DTR e RMC realizados com intervalo máximo de 06 meses e armazenados em formato digital. A espessura das paredes, volumes, função sistólica e massa ventricular esquerda foram analisados pelos métodos ecocardiográficos e pela RMC, assim como o movimento anterior sistólico da valva mitral, o índice geométrico do VE e o índice sistólico de dissincronia do VE. ANÁLISE ESTATÍSTICA: Análise estatística pelo coeficiente de concordância de Lin, correlação linear de Pearson e modelo de Bland-Altman. RESULTADOS: Foi obtida exeqüibilidade elevada acima de 94%, dependente do parâmetro avaliado. Concordância satisfatória e forte correlação linear evidenciada para a análise segmentar (Rc>0.84 e r>0.85; p<0.0001) observada para os métodos ecocardiográficos comparados à RMC, com concordância excelente entre os métodos ecocardiográficos (Rc=0,92 e r=0,92, p<0,0001). Concordância satisfatória e forte correlação linear para a fração de ejeção do VE (Rc=0.83 e r=0.93; p<0.0001) pela E3DTR comparada à RMC. Concordância excelente e forte correlação linear para o VDFVE e VSFVE pela E3DTR comparada à RMC e pela E2D comparada à E3DTR (Rc>0.90 and r>0.95; p<0.0001), assim como para a massa do VE, para os métodos E3DTR e RMC (Rc=0.96 e r=0.97; p<0.0001). Evidenciada maior exeqüibilidade da análise do MAS pela E3DTR. O índice geométrico do VE foi >0,15mmxm²xml-1 para todos os métodos. Observada correlação negativa entre o índice de dissincronia do VE e o percentual de fibrose miocárdica, sem significância estatística. CONCLUSÕES: A E3DTR é precisa e superior à E2D na avaliação da distribuição da hipertrofia miocárdica, quantificação dos volumes, função e massa ventricular esquerda em pacientes com CMH quando comparada à RMC, e parece ser superior na análise do MAS, pela melhor visão espacial da valva mitral.Todas as medidas do índice geométrico do ventrículo esquerdo estavam acima de 0,15mmxm²xml-1, compatível com CMH. Não foi identificada correlação entre o índice sistólico de dissincronia ventricular esquerda e a fibrose miocárdica. / INTRODUCTION: Real-time three-dimensional echocardiography (RT3D) has been demonstrated an accurate technique for the quantification of left ventricular (LV) volumes, ejection fraction (LVEF), and mass. In patients with hypertrophic cardiomyopathy (HCM), in which alterations of ventricular morphology are common, cardiac structural analysis is of utmost importance for guiding adequate therapy. Although magnetic resonance imaging (MRI) seems to have better definition for segmental analysis than two-dimensional echocardiography, (2D-E), it is considered a complex test with low availability and some limitations for use. METHODS: Comparative and double-blinded study in 20 patients with HCM. All patients underwent 2DE, RT3D and MRI within maximal interval of 6 months. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, systolic function, LV mass, systolic anterior motion of mitral valve, LV geometric index and LV dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. RESULTS: Feasibility for measurements by MRI and echocardiography was 94%. There was good agreement and linear correlation between segmental analysis by echocardiography and MRI (Rc>0.84 and r>0.85; p<0.0001) and excellent correlation between 2DE and RT3DE (Rc=0.92 and r=0.92; p<0.0001). We also observed good agreement and linear correlation between RT3DE and MRI for ejection fraction (Rc=0.83 and r=0.93; p<0.0001) and excellent agreement and linear correlation between RT3DE and MRI for LV end diastolic volume and LV end systolic volume determinations (Rc>0.90 and r>0.95; p<0.0001) and mass (Rc=0.96 and r=0.97; p<0.0001). The feasibility for systolic anterior motion of mitral valve was higher by RT3DE (91%) than 2DE (64%). LV geometric index was >0.15 mmxm²xml-1 for all techniques. There was no correlation between LV dyssynchrony index and the percentage of myocardial fibrosis. CONCLUSIONS: RT3D is an accurate technique with superior performance than 2DE for the evaluation of myocardial hypertrophy localization, LV volume and functional determination as well as for LV mass assessment in patients with HCM in comparison with MRI. In addition, it seems to be superior for the analysis of systolic anterior motion due to its better spatial view of mitral valve. All measurements of LV geometric index were above the value of 0.15 mmxm²xml-1, and such findings are compatible with HCM. No correlation between LV dyssynchrony index by RT3D and the percentage of myocardial fibrosis determined by MRI was identified.
7

Parâmetros ultrassonográficos bi e tridimensionais em gestações únicas com colo uterino curto / Two and three-dimensional ultrasound parameters in single pregnancies with short cervix

Marinelli, Juliana Valente Codato 19 September 2018 (has links)
INTRODUÇÃO: Pouco se sabe sobre parâmetros ultrassonográficos transvaginais possíveis de serem avaliados durante a gestação além do comprimento do colo uterino. A escassa literatura sugere que o volume calculado através da ultrassonografia tridimensional, a quantificação de sinal power Doppler em todo o órgão e o Doppler das artérias uterinas possam sofrer alterações de acordo com o comprimento cervical, e até mesmo anteceder seu encurtamento no processo que leva ao parto. OBJETIVOS: agregar novos parâmetros bi e tridimensionais ultrassonográficos à avaliação do colo uterino em gestações únicas. MÉTODO: Estudo transversal desenvolvido com dados de 2014 a janeiro de 2018 do projeto PROPE, no qual foi realizada ultrassonografia transvaginal em pacientes entre 20 e 23 semanas e 6 dias de gestação. Foram compilados e submetidos à análise secundária os dados de 162 gestantes com comprimento do colo uterino >= 25 mm (grupo Controle), 68 gestantes com comprimento do colo >= 15 mm e < 25 mm (grupo Colo Curto) e 18 gestantes com comprimento do colo < 15 mm (grupo Colo Muito Curto). Foram analisadas as características demográficas e antecedentes obstétricos das gestantes, e foram comparados entre os grupos os parâmetros cervicais de comprimento, volume e vascularização, além do Doppler de artérias uterinas bilateralmente. RESULTADOS: O comprimento médio (± DP) dos colos uterinos de cada grupo foi 35,28 ± 5,12 mm para o grupo Controle, 20,51 ± 2,47 mm para o grupo Colo Curto, e 10,72 ± 2,51 mm para o grupo Colo Muito Curto. Houve diferença entre os grupos quanto à idade materna, cor (etnia) e idade gestacional de inclusão. Quanto aos antecedentes obstétricos, houve associação somente entre a presença de colo curto na gestação atual e pelo menos um parto prematuro anterior em gestantes não nulíparas (p = 0,021). Em relação aos parâmetros ultrassonográficos, verificou-se correlação linear positiva moderada entre volume e comprimento do colo (coeficiente de Pearson=0.587, valor p < 0.0001). Os grupos Controle, Colo Curto e Colo Muito Curto foram estatisticamente diferentes em relação às médias (± DP) de volume (46,38 ± 13,60 cm vs. 32,15 ± 13,14 cm vs. 22,08 ± 11,10 cm, respectivamente)(p <= 0,001), e em relação às médias (± DP) de índice de fluxo (IF) (39,81 ± 6,42 cm vs. 38,73 ± 4,99 cm vs. 36,02 ± 5,34 cm, respectivamente) (p = 0,027), em que a diferença estatística ocorre entre os grupos Controle e Colo Muito Curto. Porém, na presença da informação do volume, após regressão linear, a associação entre os grupos e IF deixa de ser significativa. Também não houve relação entre os grupos estudados e o Doppler de artérias uterinas. CONCLUSÃO: Existe correlação linear positiva entre o volume e o comprimento do colo uterino. Na ausência de informações sobre o volume, comprimento cervical e índices de vascularização não se correlacionam. O comprimento cervical também não está relacionado a alterações no Doppler de artérias uterinas. Apesar das limitações de uma amostra pequena e escassez de dados comparativos na literatura, este estudo foi realizado com uma amostra homogênea da população e abre caminho para maiores pesquisas sobre o assunto / INTRODUCTION: Little is known about transvaginal ultrasound parameters other than cervical length that can be assessed during gestation. The literature suggests that changes in volume on three-dimensional ultrasound, quantification of power Doppler signal in the entire organ, and Doppler sonography of uterine arteries may be related to cervical length, and even precede its shortening during spontaneous delivery. OBJECTIVES: To include new two- and three-dimensional ultrasonographic parameters for evaluation of the uterine cervix in single pregnancies. METHODS: A crosssectional study of data from Project PROPE on transvaginal ultrasonography performed in patients between 20 and 23 weeks and 6 days of gestation from May 2014 to January 2018 was conducted. Secondary analysis of data from 162 pregnant women with uterine cervical length >= 25 mm (Control group), 68 pregnant women with cervical length >= 15 mm and < 25 mm (Short Cervix group), and 18 pregnant women with cervical length < 15 mm (Very Short Cervix group) was performed. The demographic characteristics and obstetric history of the pregnant women were analyzed, and the cervical length, volume, and vascularization were compared between the groups. In addition, Doppler velocimetry of the uterine arteries was performed bilaterally. RESULTS: The mean cervical length (± SD) was 35.28 ± 5.12 mm for the Control group, 20.51 ± 2.47 mm for the Short Cervix group, and 10.72 ± 2, 51 mm for the Very Short Cervix group. The groups differed in maternal age, ethnicity, and gestational age. When analyzing the obstetric history of only non-nulliparous patients we observed a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth (p = 0.021). With regard to the ultrasonographic parameters, we observed a moderate positive linear correlation between the volume and length of the cervix (Pearson coefficient = 0.587, p < 0.0001). The Control, Short Cervix, and Very Short Cervix groups showed differences in the mean (± SD) volume (46.38 ± 13.60 cm vs. 32.15 ± 13.14 cm vs. 22.08 ± 11.10 cm, respectively) (p <= 0.001) and mean (± SD) flow index (FI) parameter of cervical vascularization (39.81 ± 6.42 cm vs. 38.73 ± 4.99 cm vs. 36.02 ± 5.34 cm, respectively) (p = 0.027), and the difference between the Control and Very Short Cervix groups was statistically significant. However, after linear regression, in the presence of volume information, we found no association between the groups and FI. CONCLUSION: Cervical length and volume are positively correlated. When information about the volume is not provided, there\'s no association between cervical length and vascularization. Uterine artery Doppler is not related to cervical length. Despite the limitations of a small sample size and less comparative data in the literature, this study was performed with a homogeneous sample population and paves the way toward further research on the subject
8

Visibilização de artérias coronárias epicárdicas em imagens ecocardiográficas tridimensionais com contraste de microbolhas / Visualization of the epicardial coronary arteries in microbubble contrasted tri-dimensional echocardiographic images

Lage, Danilo Meneses 01 October 2010 (has links)
Com os avanços tecnológicos das últimas décadas, a ecocardiografia surgiu como uma alternativa de diagnóstico por imagem de relativo baixo custo, que não faz uso de energia ionizante ou radioativa. Recentemente, o advento dos agentes de contraste por microbolhas e dos transdutores matriciais tornou possível a visualização tridimensional da anatomia das artérias coronárias. Neste projeto, é proposta a avaliação de métodos de segmentação capazes de visibilizar as artérias coronárias epicárdicas em Imagens de ecocardiografias tridimensionais com contraste de microbolhas. Esse é o primeiro passo para o desenvolvimento de ferramentas computacionais eficazes e eficientes na assistência não invasiva ao acompanhamento do quadro clínico de pacientes, do diagnóstico ao pós-operatório. Propõe-se, uma metodologia que facilite o acesso às coronárias a partir de imagens de ecocardiografia tridimensionais com aplicação de contraste por microbolhas. Dentre as metodologias estudadas, as técnicas baseadas na teoria Fuzzy Connectedness (FC) foram identificadas como as mais promissoras. Estudou-se, portanto, seis abordagens baseadas nessa teoria, três delas são descritas na literatura (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) e três proposições originais (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). Para avaliar a acurácia desses algoritmos, confeccionou-se um conjunto de imagens simuladas, composto por 360 imagens, e selecionou-se um conjunto de imagens de exames reais, composto de 10 imagens reais de pacientes com quadro de Cardiomiopatia Hipertrópica. Para as imagens simuladas, os métodos da literatura alcançaram acurácia de 85,5% para GFC, 89,5% para RFC e 92,0% para DyWFC. Enquanto isso, os métodos propostos alcançaram acurácia de 88,9% para ASFC, 91,7 % para USkFC e 95,2% para GuFC. Para as imagens reais, os métodos convergiram para uma segmentação satisfatória quanto à usabilidade na clínica médica. Esses resultados demonstraram, ainda, o melhor desempenho do método proposto GuFC ante os demais. Dessa forma, ele se torna um candidato para ingressar na etapa de segmentação de uma ferramenta computacional para visibilização das coronárias epicárdicas no futuro / With the technological advances of recent decades, echocardiography has emerged as a relatively low cost imaging diagnostic alternative, that does not use ionizing or radioactive energy. Lately, the advent of microbubble-based contrast agents and array transducers turned possible the visualization of three-dimensional coronary arteries anatomy. The present project proposes to evaluate segmentation methods able to deal with the visualization of the epicardial coronary arteries in microbubble-based three-dimensional echocardiography images. This is the first step towards the development of effective and efficient computational tools for diagnosis and prognosis assistance of cardiac pacient. We propose a methodology to facilitate the access to epicardial coronary arteries in tridimensional echocardiographic images. Among the studied approaches, Fuzzy Connectednessbased segmentation methods were identified as being the most promising. We studied six approaches based on this theory, three of them are described in the literature (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) and three original contributions (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). To evaluate the accuracy of these algorithms, a set composed of 360 simulated images were created. We also selected a set of 10 real images, composed of hypertrophic cardiomyopathy patients. For simulated images set, the methods of literature achieved accuracy of 85.5% for GFC, 89,5% for RFC and 92,0% for DyWFC, meanwhile, the proposed method achieved accuracy of 88.9% for ASFC, 91,7 % for USkFC and 95,2% for GuFC. Using the real images set, the methods converged to good results for clinical purposes. These results demonstrate that the proposed method GuFC has shown a better performance than the others, becoming a candidate to the segmentation step in a computational tool for coronary arteries visualization in the future
9

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Hotta, Viviane Tiemi 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
10

Análise ecocardiográfica anatômica e funcional intraoperatória da valva mitral em pacientes com prolapso valvar submetidos à valvoplastia cirúrgica: estudo transesofágico bidimensional e tridimensional / Intraoperative anatomic and functional analyses of mitral valve in patients with valve prolapsed submitted to surgical valvuloplasty: a two-dimensional and three-dimensional transesophageal study

Pardi, Mirian Magalhães 01 December 2014 (has links)
Introdução: Embora o papel da ecocardiografia transesofágica (ETE) esteja bem estabelecido na avaliação morfológica e funcional da valva mitral e na seleção dos pacientes com prolapso da valva mitral (PVM) para a cirurgia reparadora, o impacto da ETE tridimensional (3D) no resultado cirúrgico ainda não está bem demonstrado. Os objetivos deste trabalho foram avaliar o valor diagnóstico adicional da ETE 3D em comparação com a técnica bidimensional (2D) e a associação de parâmetros anatômicos tridimensionais com o resultado cirúrgico em pacientes com PVM submetidos à valvoplastia. Métodos: Para a análise comparativa da sensibilidade, especificidade e acurácia diagnóstica entre ETE 2D e 3D, foram incluídos 62 pacientes operados por PVM com insuficiência importante, sendo a inspeção cirúrgica considerada padrão-ouro. Para a análise 3D, foram estudados 54 pacientes submetidos à plástica valvar que foram divididos em 2 grupos de acordo com o grau da insuficiência mitral pós-operatória (grupo 1, insuficiência mitral ausente ou grau I; grupo 2, insuficiência mitral grau II ou III). Foram medidos pela quantificação 3D os seguintes parâmetros anatômicos: diâmetros anteroposterior e intercomissural, altura, circunferência e área do anel mitral; comprimento, área e linha de coaptação das cúspides; volume e altura do prolapso; distância dos músculos papilares à borda da cúspide; e ângulos mitroaórtico e não planar. Para a identificação de variáveis associadas aos grupos de resultados cirúrgicos, foi realizada análise univariada (teste t de Student para as variáveis contínuas e teste qui-quadrado ou o teste de Fisher para as variáveis categóricas), análise multivariada com método de regressão logística e curva ROC para a obtenção do ponto de corte. Resultados: A ETE 2D apresentou maior sensibilidade no diagnóstico de prolapso nos segmentos A2, P1 e P3 que a ETE 3D (p = 0,019, 0,023, 0,012, respectivamente) enquanto que a ETE 3D apresentou maior especificidade no segmento P1 (p = 0,006). Não houve diferença na acurácia diagnóstica ente os dois métodos. A presença de prolapso das duas cúspides (p = 0,041) e a distância do músculo papilar posteromedial à borda da cúspide (p = 0,038) foram maiores no grupo 2. Análise multivariada identificou prolapso das duas cúspides e distância do músculo papilar posteromedial à borda da cúspide maior que 30 mm como fatores associados à insuficiência mitral pós-operatória grau II ou III (p = 0,039 e 0,015, respectivamente), e com risco de 5,3 e 6,3 vezes maior de insuficiência significativa pós-operatória, respectivamente. Conclusões: A ETE 2D e 3D apresentaram acurácia equivalente no diagnóstico de PVM, com maior sensibilidade da ETE 2D no diagnóstico de prolapso nos segmentos A2, P1 e P3, e maior especificidade da ETE 3D no segmento P1. A distância do músculo papilar posteromedial à borda da cúspide obtida pela análise quantitativa 3D e a presença de prolapso das duas cúspides mostraram associação com o grau da insuficiência mitral pós-operatória grau II e III / Background: Although the transesophageal echocardiography (TEE) is well established in the morphological and functional assessment of the mitral valve and in the choice of patients with mitral valve prolapse (MVP) eligible to valvuloplasty, the impact of tridimensional (3D) TEE on surgical results has not been well demonstrated yet. The present study aimed to evaluate the additional diagnostic value of 3D TEE in comparison with bidimensional (2D) technique, as well as the correlation between 3D anatomical parameters and the surgical results in patients with MVP submitted to valvuloplasty. Methods: In order to compare the sensitivity, specificity, and accuracy between 2D and 3D TEE, 62 patients with MVP and severe mitral regurgitation were enrolled; surgical appraisal was considered as the gold-standard. Regarding 3D analysis, 54 patients submitted to valvuloplasty were divided in two groups, according to their postoperative mitral regurgitation grades (group 1, absent or grade I mitral regurgitation; and group 2, grade II or III mitral regurgitation). The following parameters were assessed quantitatively by 3D TEE: anteroposterior diameter, commissural width, height, circumference and area of the mitral ring; anterior and posterior leaflets length, leaflets surface area, coaptation length, volume and height billow; distance from the tip of the anterolateral and posteromedial papillary muscle to leaflet border; non-planar and aortic-mitral angles. Univariate analysis (Student t test for continuous variables and Chi-square or Fischer test to the categorical ones), multivariate and ROC curve analyses were performed to identify the relationship between anatomical parameters and surgical results (p < 5%). Results: 2D TEE showed higher sensitivity to diagnose MVP in A2, P1, and P3 segments, when compared with 3D TEE (p= 0.019, 0.023, and 0.012, respectively), while 3D TEE showed greater specificity to identify P1 segment (p= 0.006). No difference was observed in the accuracy between both methods. The presence of bileaflet prolapse (p= 0.041) and the distance from posteromedial papillary muscle to leaflet border (p= 0.038) were higher in group 2. Multivariate analysis showed that bileaflet prolapse and distance of more than 30 mm from posteromedial papillary muscle to leaflet border were related to grade II or III postoperative mitral regurgitation (p= 0.039 and 0.015, respectively), representing 5.3 and 6.3 more risk of significant mitral regurgitation, respectively. Conclusions: Both 2D TEE and 3D TEE presented similar accuracy in the diagnosis of MVP; 2D TEE showed higher sensitivity to diagnose the prolapse in A2, P1 and P3 segments, while the 3D TEE presented greater specificity to identify the affected P1 segment. The distance from the tip of the posteromedial papillary muscle to the leaflet border quantitatively estimated by 3D TEE and the evidence of bileaflet prolapse showed to be associated to the degree of mitral regurgitation after valvuloplasty