• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 16
  • 14
  • 14
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Parâmetros ultrassonográficos bi e tridimensionais em gestações únicas com colo uterino curto / Two and three-dimensional ultrasound parameters in single pregnancies with short cervix

Juliana Valente Codato Marinelli 19 September 2018 (has links)
INTRODUÇÃO: Pouco se sabe sobre parâmetros ultrassonográficos transvaginais possíveis de serem avaliados durante a gestação além do comprimento do colo uterino. A escassa literatura sugere que o volume calculado através da ultrassonografia tridimensional, a quantificação de sinal power Doppler em todo o órgão e o Doppler das artérias uterinas possam sofrer alterações de acordo com o comprimento cervical, e até mesmo anteceder seu encurtamento no processo que leva ao parto. OBJETIVOS: agregar novos parâmetros bi e tridimensionais ultrassonográficos à avaliação do colo uterino em gestações únicas. MÉTODO: Estudo transversal desenvolvido com dados de 2014 a janeiro de 2018 do projeto PROPE, no qual foi realizada ultrassonografia transvaginal em pacientes entre 20 e 23 semanas e 6 dias de gestação. Foram compilados e submetidos à análise secundária os dados de 162 gestantes com comprimento do colo uterino >= 25 mm (grupo Controle), 68 gestantes com comprimento do colo >= 15 mm e < 25 mm (grupo Colo Curto) e 18 gestantes com comprimento do colo < 15 mm (grupo Colo Muito Curto). Foram analisadas as características demográficas e antecedentes obstétricos das gestantes, e foram comparados entre os grupos os parâmetros cervicais de comprimento, volume e vascularização, além do Doppler de artérias uterinas bilateralmente. RESULTADOS: O comprimento médio (± DP) dos colos uterinos de cada grupo foi 35,28 ± 5,12 mm para o grupo Controle, 20,51 ± 2,47 mm para o grupo Colo Curto, e 10,72 ± 2,51 mm para o grupo Colo Muito Curto. Houve diferença entre os grupos quanto à idade materna, cor (etnia) e idade gestacional de inclusão. Quanto aos antecedentes obstétricos, houve associação somente entre a presença de colo curto na gestação atual e pelo menos um parto prematuro anterior em gestantes não nulíparas (p = 0,021). Em relação aos parâmetros ultrassonográficos, verificou-se correlação linear positiva moderada entre volume e comprimento do colo (coeficiente de Pearson=0.587, valor p < 0.0001). Os grupos Controle, Colo Curto e Colo Muito Curto foram estatisticamente diferentes em relação às médias (± DP) de volume (46,38 ± 13,60 cm vs. 32,15 ± 13,14 cm vs. 22,08 ± 11,10 cm, respectivamente)(p <= 0,001), e em relação às médias (± DP) de índice de fluxo (IF) (39,81 ± 6,42 cm vs. 38,73 ± 4,99 cm vs. 36,02 ± 5,34 cm, respectivamente) (p = 0,027), em que a diferença estatística ocorre entre os grupos Controle e Colo Muito Curto. Porém, na presença da informação do volume, após regressão linear, a associação entre os grupos e IF deixa de ser significativa. Também não houve relação entre os grupos estudados e o Doppler de artérias uterinas. CONCLUSÃO: Existe correlação linear positiva entre o volume e o comprimento do colo uterino. Na ausência de informações sobre o volume, comprimento cervical e índices de vascularização não se correlacionam. O comprimento cervical também não está relacionado a alterações no Doppler de artérias uterinas. Apesar das limitações de uma amostra pequena e escassez de dados comparativos na literatura, este estudo foi realizado com uma amostra homogênea da população e abre caminho para maiores pesquisas sobre o assunto / INTRODUCTION: Little is known about transvaginal ultrasound parameters other than cervical length that can be assessed during gestation. The literature suggests that changes in volume on three-dimensional ultrasound, quantification of power Doppler signal in the entire organ, and Doppler sonography of uterine arteries may be related to cervical length, and even precede its shortening during spontaneous delivery. OBJECTIVES: To include new two- and three-dimensional ultrasonographic parameters for evaluation of the uterine cervix in single pregnancies. METHODS: A crosssectional study of data from Project PROPE on transvaginal ultrasonography performed in patients between 20 and 23 weeks and 6 days of gestation from May 2014 to January 2018 was conducted. Secondary analysis of data from 162 pregnant women with uterine cervical length >= 25 mm (Control group), 68 pregnant women with cervical length >= 15 mm and < 25 mm (Short Cervix group), and 18 pregnant women with cervical length < 15 mm (Very Short Cervix group) was performed. The demographic characteristics and obstetric history of the pregnant women were analyzed, and the cervical length, volume, and vascularization were compared between the groups. In addition, Doppler velocimetry of the uterine arteries was performed bilaterally. RESULTS: The mean cervical length (± SD) was 35.28 ± 5.12 mm for the Control group, 20.51 ± 2.47 mm for the Short Cervix group, and 10.72 ± 2, 51 mm for the Very Short Cervix group. The groups differed in maternal age, ethnicity, and gestational age. When analyzing the obstetric history of only non-nulliparous patients we observed a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth (p = 0.021). With regard to the ultrasonographic parameters, we observed a moderate positive linear correlation between the volume and length of the cervix (Pearson coefficient = 0.587, p < 0.0001). The Control, Short Cervix, and Very Short Cervix groups showed differences in the mean (± SD) volume (46.38 ± 13.60 cm vs. 32.15 ± 13.14 cm vs. 22.08 ± 11.10 cm, respectively) (p <= 0.001) and mean (± SD) flow index (FI) parameter of cervical vascularization (39.81 ± 6.42 cm vs. 38.73 ± 4.99 cm vs. 36.02 ± 5.34 cm, respectively) (p = 0.027), and the difference between the Control and Very Short Cervix groups was statistically significant. However, after linear regression, in the presence of volume information, we found no association between the groups and FI. CONCLUSION: Cervical length and volume are positively correlated. When information about the volume is not provided, there\'s no association between cervical length and vascularization. Uterine artery Doppler is not related to cervical length. Despite the limitations of a small sample size and less comparative data in the literature, this study was performed with a homogeneous sample population and paves the way toward further research on the subject
12

Valor da ecocardiografia tridimensional em tempo real em portadores de cardiomiopatia hipertrófica. Comparação com a ecocardiografia bidimensional e a ressonância magnética cardiovascular / Value of real-time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy. Comparison with twodimensional echocardiography and magnetic resonance imaging

Leticia Santos Bicudo 30 November 2007 (has links)
INTRODUÇÃO: A ecocardiografia tridimensional em tempo real (E3DTR) vem provando sua acurácia para quantificar os volumes do ventrículo esquerdo (VE), fração de ejeção (FEVE) e massa em pacientes com cardiomiopatia. Na cardiomiopatia hipertrófica (CMH), onde a morfologia ventricular pode estar muito alterada, a análise das estruturas cardíacas é fundamental para indicação da terapêutica ideal. A ressonância magnética cardiovascular (RMC) é um método superior na análise segmentar do VE em comparação a ecocardiografia bidimensional (E2D), mas com alta complexidade e existente em poucos centros diagnósticos, com contraindicações e limitações para a sua realização. MÉTODOS: Estudo transversal, comparativo, duplo cego, em 20 portadores de CMH, com E2D, E3DTR e RMC realizados com intervalo máximo de 06 meses e armazenados em formato digital. A espessura das paredes, volumes, função sistólica e massa ventricular esquerda foram analisados pelos métodos ecocardiográficos e pela RMC, assim como o movimento anterior sistólico da valva mitral, o índice geométrico do VE e o índice sistólico de dissincronia do VE. ANÁLISE ESTATÍSTICA: Análise estatística pelo coeficiente de concordância de Lin, correlação linear de Pearson e modelo de Bland-Altman. RESULTADOS: Foi obtida exeqüibilidade elevada acima de 94%, dependente do parâmetro avaliado. Concordância satisfatória e forte correlação linear evidenciada para a análise segmentar (Rc>0.84 e r>0.85; p<0.0001) observada para os métodos ecocardiográficos comparados à RMC, com concordância excelente entre os métodos ecocardiográficos (Rc=0,92 e r=0,92, p<0,0001). Concordância satisfatória e forte correlação linear para a fração de ejeção do VE (Rc=0.83 e r=0.93; p<0.0001) pela E3DTR comparada à RMC. Concordância excelente e forte correlação linear para o VDFVE e VSFVE pela E3DTR comparada à RMC e pela E2D comparada à E3DTR (Rc>0.90 and r>0.95; p<0.0001), assim como para a massa do VE, para os métodos E3DTR e RMC (Rc=0.96 e r=0.97; p<0.0001). Evidenciada maior exeqüibilidade da análise do MAS pela E3DTR. O índice geométrico do VE foi >0,15mmxm²xml-1 para todos os métodos. Observada correlação negativa entre o índice de dissincronia do VE e o percentual de fibrose miocárdica, sem significância estatística. CONCLUSÕES: A E3DTR é precisa e superior à E2D na avaliação da distribuição da hipertrofia miocárdica, quantificação dos volumes, função e massa ventricular esquerda em pacientes com CMH quando comparada à RMC, e parece ser superior na análise do MAS, pela melhor visão espacial da valva mitral.Todas as medidas do índice geométrico do ventrículo esquerdo estavam acima de 0,15mmxm²xml-1, compatível com CMH. Não foi identificada correlação entre o índice sistólico de dissincronia ventricular esquerda e a fibrose miocárdica. / INTRODUCTION: Real-time three-dimensional echocardiography (RT3D) has been demonstrated an accurate technique for the quantification of left ventricular (LV) volumes, ejection fraction (LVEF), and mass. In patients with hypertrophic cardiomyopathy (HCM), in which alterations of ventricular morphology are common, cardiac structural analysis is of utmost importance for guiding adequate therapy. Although magnetic resonance imaging (MRI) seems to have better definition for segmental analysis than two-dimensional echocardiography, (2D-E), it is considered a complex test with low availability and some limitations for use. METHODS: Comparative and double-blinded study in 20 patients with HCM. All patients underwent 2DE, RT3D and MRI within maximal interval of 6 months. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, systolic function, LV mass, systolic anterior motion of mitral valve, LV geometric index and LV dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. RESULTS: Feasibility for measurements by MRI and echocardiography was 94%. There was good agreement and linear correlation between segmental analysis by echocardiography and MRI (Rc>0.84 and r>0.85; p<0.0001) and excellent correlation between 2DE and RT3DE (Rc=0.92 and r=0.92; p<0.0001). We also observed good agreement and linear correlation between RT3DE and MRI for ejection fraction (Rc=0.83 and r=0.93; p<0.0001) and excellent agreement and linear correlation between RT3DE and MRI for LV end diastolic volume and LV end systolic volume determinations (Rc>0.90 and r>0.95; p<0.0001) and mass (Rc=0.96 and r=0.97; p<0.0001). The feasibility for systolic anterior motion of mitral valve was higher by RT3DE (91%) than 2DE (64%). LV geometric index was >0.15 mmxm²xml-1 for all techniques. There was no correlation between LV dyssynchrony index and the percentage of myocardial fibrosis. CONCLUSIONS: RT3D is an accurate technique with superior performance than 2DE for the evaluation of myocardial hypertrophy localization, LV volume and functional determination as well as for LV mass assessment in patients with HCM in comparison with MRI. In addition, it seems to be superior for the analysis of systolic anterior motion due to its better spatial view of mitral valve. All measurements of LV geometric index were above the value of 0.15 mmxm²xml-1, and such findings are compatible with HCM. No correlation between LV dyssynchrony index by RT3D and the percentage of myocardial fibrosis determined by MRI was identified.
13

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Viviane Tiemi Hotta 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
14

Análise ecocardiográfica anatômica e funcional intraoperatória da valva mitral em pacientes com prolapso valvar submetidos à valvoplastia cirúrgica: estudo transesofágico bidimensional e tridimensional / Intraoperative anatomic and functional analyses of mitral valve in patients with valve prolapsed submitted to surgical valvuloplasty: a two-dimensional and three-dimensional transesophageal study

Mirian Magalhães Pardi 01 December 2014 (has links)
Introdução: Embora o papel da ecocardiografia transesofágica (ETE) esteja bem estabelecido na avaliação morfológica e funcional da valva mitral e na seleção dos pacientes com prolapso da valva mitral (PVM) para a cirurgia reparadora, o impacto da ETE tridimensional (3D) no resultado cirúrgico ainda não está bem demonstrado. Os objetivos deste trabalho foram avaliar o valor diagnóstico adicional da ETE 3D em comparação com a técnica bidimensional (2D) e a associação de parâmetros anatômicos tridimensionais com o resultado cirúrgico em pacientes com PVM submetidos à valvoplastia. Métodos: Para a análise comparativa da sensibilidade, especificidade e acurácia diagnóstica entre ETE 2D e 3D, foram incluídos 62 pacientes operados por PVM com insuficiência importante, sendo a inspeção cirúrgica considerada padrão-ouro. Para a análise 3D, foram estudados 54 pacientes submetidos à plástica valvar que foram divididos em 2 grupos de acordo com o grau da insuficiência mitral pós-operatória (grupo 1, insuficiência mitral ausente ou grau I; grupo 2, insuficiência mitral grau II ou III). Foram medidos pela quantificação 3D os seguintes parâmetros anatômicos: diâmetros anteroposterior e intercomissural, altura, circunferência e área do anel mitral; comprimento, área e linha de coaptação das cúspides; volume e altura do prolapso; distância dos músculos papilares à borda da cúspide; e ângulos mitroaórtico e não planar. Para a identificação de variáveis associadas aos grupos de resultados cirúrgicos, foi realizada análise univariada (teste t de Student para as variáveis contínuas e teste qui-quadrado ou o teste de Fisher para as variáveis categóricas), análise multivariada com método de regressão logística e curva ROC para a obtenção do ponto de corte. Resultados: A ETE 2D apresentou maior sensibilidade no diagnóstico de prolapso nos segmentos A2, P1 e P3 que a ETE 3D (p = 0,019, 0,023, 0,012, respectivamente) enquanto que a ETE 3D apresentou maior especificidade no segmento P1 (p = 0,006). Não houve diferença na acurácia diagnóstica ente os dois métodos. A presença de prolapso das duas cúspides (p = 0,041) e a distância do músculo papilar posteromedial à borda da cúspide (p = 0,038) foram maiores no grupo 2. Análise multivariada identificou prolapso das duas cúspides e distância do músculo papilar posteromedial à borda da cúspide maior que 30 mm como fatores associados à insuficiência mitral pós-operatória grau II ou III (p = 0,039 e 0,015, respectivamente), e com risco de 5,3 e 6,3 vezes maior de insuficiência significativa pós-operatória, respectivamente. Conclusões: A ETE 2D e 3D apresentaram acurácia equivalente no diagnóstico de PVM, com maior sensibilidade da ETE 2D no diagnóstico de prolapso nos segmentos A2, P1 e P3, e maior especificidade da ETE 3D no segmento P1. A distância do músculo papilar posteromedial à borda da cúspide obtida pela análise quantitativa 3D e a presença de prolapso das duas cúspides mostraram associação com o grau da insuficiência mitral pós-operatória grau II e III / Background: Although the transesophageal echocardiography (TEE) is well established in the morphological and functional assessment of the mitral valve and in the choice of patients with mitral valve prolapse (MVP) eligible to valvuloplasty, the impact of tridimensional (3D) TEE on surgical results has not been well demonstrated yet. The present study aimed to evaluate the additional diagnostic value of 3D TEE in comparison with bidimensional (2D) technique, as well as the correlation between 3D anatomical parameters and the surgical results in patients with MVP submitted to valvuloplasty. Methods: In order to compare the sensitivity, specificity, and accuracy between 2D and 3D TEE, 62 patients with MVP and severe mitral regurgitation were enrolled; surgical appraisal was considered as the gold-standard. Regarding 3D analysis, 54 patients submitted to valvuloplasty were divided in two groups, according to their postoperative mitral regurgitation grades (group 1, absent or grade I mitral regurgitation; and group 2, grade II or III mitral regurgitation). The following parameters were assessed quantitatively by 3D TEE: anteroposterior diameter, commissural width, height, circumference and area of the mitral ring; anterior and posterior leaflets length, leaflets surface area, coaptation length, volume and height billow; distance from the tip of the anterolateral and posteromedial papillary muscle to leaflet border; non-planar and aortic-mitral angles. Univariate analysis (Student t test for continuous variables and Chi-square or Fischer test to the categorical ones), multivariate and ROC curve analyses were performed to identify the relationship between anatomical parameters and surgical results (p < 5%). Results: 2D TEE showed higher sensitivity to diagnose MVP in A2, P1, and P3 segments, when compared with 3D TEE (p= 0.019, 0.023, and 0.012, respectively), while 3D TEE showed greater specificity to identify P1 segment (p= 0.006). No difference was observed in the accuracy between both methods. The presence of bileaflet prolapse (p= 0.041) and the distance from posteromedial papillary muscle to leaflet border (p= 0.038) were higher in group 2. Multivariate analysis showed that bileaflet prolapse and distance of more than 30 mm from posteromedial papillary muscle to leaflet border were related to grade II or III postoperative mitral regurgitation (p= 0.039 and 0.015, respectively), representing 5.3 and 6.3 more risk of significant mitral regurgitation, respectively. Conclusions: Both 2D TEE and 3D TEE presented similar accuracy in the diagnosis of MVP; 2D TEE showed higher sensitivity to diagnose the prolapse in A2, P1 and P3 segments, while the 3D TEE presented greater specificity to identify the affected P1 segment. The distance from the tip of the posteromedial papillary muscle to the leaflet border quantitatively estimated by 3D TEE and the evidence of bileaflet prolapse showed to be associated to the degree of mitral regurgitation after valvuloplasty
15

Visibilização de artérias coronárias epicárdicas em imagens ecocardiográficas tridimensionais com contraste de microbolhas / Visualization of the epicardial coronary arteries in microbubble contrasted tri-dimensional echocardiographic images

Danilo Meneses Lage 01 October 2010 (has links)
Com os avanços tecnológicos das últimas décadas, a ecocardiografia surgiu como uma alternativa de diagnóstico por imagem de relativo baixo custo, que não faz uso de energia ionizante ou radioativa. Recentemente, o advento dos agentes de contraste por microbolhas e dos transdutores matriciais tornou possível a visualização tridimensional da anatomia das artérias coronárias. Neste projeto, é proposta a avaliação de métodos de segmentação capazes de visibilizar as artérias coronárias epicárdicas em Imagens de ecocardiografias tridimensionais com contraste de microbolhas. Esse é o primeiro passo para o desenvolvimento de ferramentas computacionais eficazes e eficientes na assistência não invasiva ao acompanhamento do quadro clínico de pacientes, do diagnóstico ao pós-operatório. Propõe-se, uma metodologia que facilite o acesso às coronárias a partir de imagens de ecocardiografia tridimensionais com aplicação de contraste por microbolhas. Dentre as metodologias estudadas, as técnicas baseadas na teoria Fuzzy Connectedness (FC) foram identificadas como as mais promissoras. Estudou-se, portanto, seis abordagens baseadas nessa teoria, três delas são descritas na literatura (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) e três proposições originais (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). Para avaliar a acurácia desses algoritmos, confeccionou-se um conjunto de imagens simuladas, composto por 360 imagens, e selecionou-se um conjunto de imagens de exames reais, composto de 10 imagens reais de pacientes com quadro de Cardiomiopatia Hipertrópica. Para as imagens simuladas, os métodos da literatura alcançaram acurácia de 85,5% para GFC, 89,5% para RFC e 92,0% para DyWFC. Enquanto isso, os métodos propostos alcançaram acurácia de 88,9% para ASFC, 91,7 % para USkFC e 95,2% para GuFC. Para as imagens reais, os métodos convergiram para uma segmentação satisfatória quanto à usabilidade na clínica médica. Esses resultados demonstraram, ainda, o melhor desempenho do método proposto GuFC ante os demais. Dessa forma, ele se torna um candidato para ingressar na etapa de segmentação de uma ferramenta computacional para visibilização das coronárias epicárdicas no futuro / With the technological advances of recent decades, echocardiography has emerged as a relatively low cost imaging diagnostic alternative, that does not use ionizing or radioactive energy. Lately, the advent of microbubble-based contrast agents and array transducers turned possible the visualization of three-dimensional coronary arteries anatomy. The present project proposes to evaluate segmentation methods able to deal with the visualization of the epicardial coronary arteries in microbubble-based three-dimensional echocardiography images. This is the first step towards the development of effective and efficient computational tools for diagnosis and prognosis assistance of cardiac pacient. We propose a methodology to facilitate the access to epicardial coronary arteries in tridimensional echocardiographic images. Among the studied approaches, Fuzzy Connectednessbased segmentation methods were identified as being the most promising. We studied six approaches based on this theory, three of them are described in the literature (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) and three original contributions (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). To evaluate the accuracy of these algorithms, a set composed of 360 simulated images were created. We also selected a set of 10 real images, composed of hypertrophic cardiomyopathy patients. For simulated images set, the methods of literature achieved accuracy of 85.5% for GFC, 89,5% for RFC and 92,0% for DyWFC, meanwhile, the proposed method achieved accuracy of 88.9% for ASFC, 91,7 % for USkFC and 95,2% for GuFC. Using the real images set, the methods converged to good results for clinical purposes. These results demonstrate that the proposed method GuFC has shown a better performance than the others, becoming a candidate to the segmentation step in a computational tool for coronary arteries visualization in the future
16

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Guedes, Marco Antonio Vieira 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
17

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Marco Antonio Vieira Guedes 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function

Page generated in 0.1209 seconds