• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Parâmetros ultrassonográficos bi e tridimensionais em gestações únicas com colo uterino curto / Two and three-dimensional ultrasound parameters in single pregnancies with short cervix

Marinelli, Juliana Valente Codato 19 September 2018 (has links)
INTRODUÇÃO: Pouco se sabe sobre parâmetros ultrassonográficos transvaginais possíveis de serem avaliados durante a gestação além do comprimento do colo uterino. A escassa literatura sugere que o volume calculado através da ultrassonografia tridimensional, a quantificação de sinal power Doppler em todo o órgão e o Doppler das artérias uterinas possam sofrer alterações de acordo com o comprimento cervical, e até mesmo anteceder seu encurtamento no processo que leva ao parto. OBJETIVOS: agregar novos parâmetros bi e tridimensionais ultrassonográficos à avaliação do colo uterino em gestações únicas. MÉTODO: Estudo transversal desenvolvido com dados de 2014 a janeiro de 2018 do projeto PROPE, no qual foi realizada ultrassonografia transvaginal em pacientes entre 20 e 23 semanas e 6 dias de gestação. Foram compilados e submetidos à análise secundária os dados de 162 gestantes com comprimento do colo uterino >= 25 mm (grupo Controle), 68 gestantes com comprimento do colo >= 15 mm e < 25 mm (grupo Colo Curto) e 18 gestantes com comprimento do colo < 15 mm (grupo Colo Muito Curto). Foram analisadas as características demográficas e antecedentes obstétricos das gestantes, e foram comparados entre os grupos os parâmetros cervicais de comprimento, volume e vascularização, além do Doppler de artérias uterinas bilateralmente. RESULTADOS: O comprimento médio (± DP) dos colos uterinos de cada grupo foi 35,28 ± 5,12 mm para o grupo Controle, 20,51 ± 2,47 mm para o grupo Colo Curto, e 10,72 ± 2,51 mm para o grupo Colo Muito Curto. Houve diferença entre os grupos quanto à idade materna, cor (etnia) e idade gestacional de inclusão. Quanto aos antecedentes obstétricos, houve associação somente entre a presença de colo curto na gestação atual e pelo menos um parto prematuro anterior em gestantes não nulíparas (p = 0,021). Em relação aos parâmetros ultrassonográficos, verificou-se correlação linear positiva moderada entre volume e comprimento do colo (coeficiente de Pearson=0.587, valor p < 0.0001). Os grupos Controle, Colo Curto e Colo Muito Curto foram estatisticamente diferentes em relação às médias (± DP) de volume (46,38 ± 13,60 cm vs. 32,15 ± 13,14 cm vs. 22,08 ± 11,10 cm, respectivamente)(p <= 0,001), e em relação às médias (± DP) de índice de fluxo (IF) (39,81 ± 6,42 cm vs. 38,73 ± 4,99 cm vs. 36,02 ± 5,34 cm, respectivamente) (p = 0,027), em que a diferença estatística ocorre entre os grupos Controle e Colo Muito Curto. Porém, na presença da informação do volume, após regressão linear, a associação entre os grupos e IF deixa de ser significativa. Também não houve relação entre os grupos estudados e o Doppler de artérias uterinas. CONCLUSÃO: Existe correlação linear positiva entre o volume e o comprimento do colo uterino. Na ausência de informações sobre o volume, comprimento cervical e índices de vascularização não se correlacionam. O comprimento cervical também não está relacionado a alterações no Doppler de artérias uterinas. Apesar das limitações de uma amostra pequena e escassez de dados comparativos na literatura, este estudo foi realizado com uma amostra homogênea da população e abre caminho para maiores pesquisas sobre o assunto / INTRODUCTION: Little is known about transvaginal ultrasound parameters other than cervical length that can be assessed during gestation. The literature suggests that changes in volume on three-dimensional ultrasound, quantification of power Doppler signal in the entire organ, and Doppler sonography of uterine arteries may be related to cervical length, and even precede its shortening during spontaneous delivery. OBJECTIVES: To include new two- and three-dimensional ultrasonographic parameters for evaluation of the uterine cervix in single pregnancies. METHODS: A crosssectional study of data from Project PROPE on transvaginal ultrasonography performed in patients between 20 and 23 weeks and 6 days of gestation from May 2014 to January 2018 was conducted. Secondary analysis of data from 162 pregnant women with uterine cervical length >= 25 mm (Control group), 68 pregnant women with cervical length >= 15 mm and < 25 mm (Short Cervix group), and 18 pregnant women with cervical length < 15 mm (Very Short Cervix group) was performed. The demographic characteristics and obstetric history of the pregnant women were analyzed, and the cervical length, volume, and vascularization were compared between the groups. In addition, Doppler velocimetry of the uterine arteries was performed bilaterally. RESULTS: The mean cervical length (± SD) was 35.28 ± 5.12 mm for the Control group, 20.51 ± 2.47 mm for the Short Cervix group, and 10.72 ± 2, 51 mm for the Very Short Cervix group. The groups differed in maternal age, ethnicity, and gestational age. When analyzing the obstetric history of only non-nulliparous patients we observed a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth (p = 0.021). With regard to the ultrasonographic parameters, we observed a moderate positive linear correlation between the volume and length of the cervix (Pearson coefficient = 0.587, p < 0.0001). The Control, Short Cervix, and Very Short Cervix groups showed differences in the mean (± SD) volume (46.38 ± 13.60 cm vs. 32.15 ± 13.14 cm vs. 22.08 ± 11.10 cm, respectively) (p <= 0.001) and mean (± SD) flow index (FI) parameter of cervical vascularization (39.81 ± 6.42 cm vs. 38.73 ± 4.99 cm vs. 36.02 ± 5.34 cm, respectively) (p = 0.027), and the difference between the Control and Very Short Cervix groups was statistically significant. However, after linear regression, in the presence of volume information, we found no association between the groups and FI. CONCLUSION: Cervical length and volume are positively correlated. When information about the volume is not provided, there\'s no association between cervical length and vascularization. Uterine artery Doppler is not related to cervical length. Despite the limitations of a small sample size and less comparative data in the literature, this study was performed with a homogeneous sample population and paves the way toward further research on the subject
2

Parâmetros ultrassonográficos bi e tridimensionais em gestações únicas com colo uterino curto / Two and three-dimensional ultrasound parameters in single pregnancies with short cervix

Juliana Valente Codato Marinelli 19 September 2018 (has links)
INTRODUÇÃO: Pouco se sabe sobre parâmetros ultrassonográficos transvaginais possíveis de serem avaliados durante a gestação além do comprimento do colo uterino. A escassa literatura sugere que o volume calculado através da ultrassonografia tridimensional, a quantificação de sinal power Doppler em todo o órgão e o Doppler das artérias uterinas possam sofrer alterações de acordo com o comprimento cervical, e até mesmo anteceder seu encurtamento no processo que leva ao parto. OBJETIVOS: agregar novos parâmetros bi e tridimensionais ultrassonográficos à avaliação do colo uterino em gestações únicas. MÉTODO: Estudo transversal desenvolvido com dados de 2014 a janeiro de 2018 do projeto PROPE, no qual foi realizada ultrassonografia transvaginal em pacientes entre 20 e 23 semanas e 6 dias de gestação. Foram compilados e submetidos à análise secundária os dados de 162 gestantes com comprimento do colo uterino >= 25 mm (grupo Controle), 68 gestantes com comprimento do colo >= 15 mm e < 25 mm (grupo Colo Curto) e 18 gestantes com comprimento do colo < 15 mm (grupo Colo Muito Curto). Foram analisadas as características demográficas e antecedentes obstétricos das gestantes, e foram comparados entre os grupos os parâmetros cervicais de comprimento, volume e vascularização, além do Doppler de artérias uterinas bilateralmente. RESULTADOS: O comprimento médio (± DP) dos colos uterinos de cada grupo foi 35,28 ± 5,12 mm para o grupo Controle, 20,51 ± 2,47 mm para o grupo Colo Curto, e 10,72 ± 2,51 mm para o grupo Colo Muito Curto. Houve diferença entre os grupos quanto à idade materna, cor (etnia) e idade gestacional de inclusão. Quanto aos antecedentes obstétricos, houve associação somente entre a presença de colo curto na gestação atual e pelo menos um parto prematuro anterior em gestantes não nulíparas (p = 0,021). Em relação aos parâmetros ultrassonográficos, verificou-se correlação linear positiva moderada entre volume e comprimento do colo (coeficiente de Pearson=0.587, valor p < 0.0001). Os grupos Controle, Colo Curto e Colo Muito Curto foram estatisticamente diferentes em relação às médias (± DP) de volume (46,38 ± 13,60 cm vs. 32,15 ± 13,14 cm vs. 22,08 ± 11,10 cm, respectivamente)(p <= 0,001), e em relação às médias (± DP) de índice de fluxo (IF) (39,81 ± 6,42 cm vs. 38,73 ± 4,99 cm vs. 36,02 ± 5,34 cm, respectivamente) (p = 0,027), em que a diferença estatística ocorre entre os grupos Controle e Colo Muito Curto. Porém, na presença da informação do volume, após regressão linear, a associação entre os grupos e IF deixa de ser significativa. Também não houve relação entre os grupos estudados e o Doppler de artérias uterinas. CONCLUSÃO: Existe correlação linear positiva entre o volume e o comprimento do colo uterino. Na ausência de informações sobre o volume, comprimento cervical e índices de vascularização não se correlacionam. O comprimento cervical também não está relacionado a alterações no Doppler de artérias uterinas. Apesar das limitações de uma amostra pequena e escassez de dados comparativos na literatura, este estudo foi realizado com uma amostra homogênea da população e abre caminho para maiores pesquisas sobre o assunto / INTRODUCTION: Little is known about transvaginal ultrasound parameters other than cervical length that can be assessed during gestation. The literature suggests that changes in volume on three-dimensional ultrasound, quantification of power Doppler signal in the entire organ, and Doppler sonography of uterine arteries may be related to cervical length, and even precede its shortening during spontaneous delivery. OBJECTIVES: To include new two- and three-dimensional ultrasonographic parameters for evaluation of the uterine cervix in single pregnancies. METHODS: A crosssectional study of data from Project PROPE on transvaginal ultrasonography performed in patients between 20 and 23 weeks and 6 days of gestation from May 2014 to January 2018 was conducted. Secondary analysis of data from 162 pregnant women with uterine cervical length >= 25 mm (Control group), 68 pregnant women with cervical length >= 15 mm and < 25 mm (Short Cervix group), and 18 pregnant women with cervical length < 15 mm (Very Short Cervix group) was performed. The demographic characteristics and obstetric history of the pregnant women were analyzed, and the cervical length, volume, and vascularization were compared between the groups. In addition, Doppler velocimetry of the uterine arteries was performed bilaterally. RESULTS: The mean cervical length (± SD) was 35.28 ± 5.12 mm for the Control group, 20.51 ± 2.47 mm for the Short Cervix group, and 10.72 ± 2, 51 mm for the Very Short Cervix group. The groups differed in maternal age, ethnicity, and gestational age. When analyzing the obstetric history of only non-nulliparous patients we observed a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth (p = 0.021). With regard to the ultrasonographic parameters, we observed a moderate positive linear correlation between the volume and length of the cervix (Pearson coefficient = 0.587, p < 0.0001). The Control, Short Cervix, and Very Short Cervix groups showed differences in the mean (± SD) volume (46.38 ± 13.60 cm vs. 32.15 ± 13.14 cm vs. 22.08 ± 11.10 cm, respectively) (p <= 0.001) and mean (± SD) flow index (FI) parameter of cervical vascularization (39.81 ± 6.42 cm vs. 38.73 ± 4.99 cm vs. 36.02 ± 5.34 cm, respectively) (p = 0.027), and the difference between the Control and Very Short Cervix groups was statistically significant. However, after linear regression, in the presence of volume information, we found no association between the groups and FI. CONCLUSION: Cervical length and volume are positively correlated. When information about the volume is not provided, there\'s no association between cervical length and vascularization. Uterine artery Doppler is not related to cervical length. Despite the limitations of a small sample size and less comparative data in the literature, this study was performed with a homogeneous sample population and paves the way toward further research on the subject
3

Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm delivery

Rolnik, Daniel Lorber 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks
4

Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm delivery

Daniel Lorber Rolnik 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks

Page generated in 0.0939 seconds