Return to search

Avaliação do sistema petrifilm™ na enumeração de micro-organismos indicadores da qualidade higiênico-sanitária e patogênicos no leite de origem ovina

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-05-14T12:14:28Z
No. of bitstreams: 1
2013_LoianeMayraJacoSouza.pdf: 949233 bytes, checksum: 3bb2b57e28e62e2465daf45a9bc7a6cf (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-05-15T11:25:57Z (GMT) No. of bitstreams: 1
2013_LoianeMayraJacoSouza.pdf: 949233 bytes, checksum: 3bb2b57e28e62e2465daf45a9bc7a6cf (MD5) / Made available in DSpace on 2013-05-15T11:25:57Z (GMT). No. of bitstreams: 1
2013_LoianeMayraJacoSouza.pdf: 949233 bytes, checksum: 3bb2b57e28e62e2465daf45a9bc7a6cf (MD5) / O objetivo deste trabalho foi avaliar a aplicabilidade do sistema Petrifilm™ na
enumeração de micro-organismos indicadores da qualidade higiênica e sanitária
(aeróbios mesófilos, coliformes totais e bactérias ácido-láticas) e patogênicos
(Staphylococcus aureus e Escherichia coli) no leite de origem ovina. As amostras de
leite de ovelha (n=30) foram semeadas simultaneamente, de acordo com as
TMmetodologias convencionais (ICMSF; AOAC) e em sistema Petrifilm . Os
resultados foram comparados utilizando os testes de McNemar e Regressão Linear.
Os resultados demosntraram boa correlação entre as metodologias convencionais e
o sistema Petrifilm™. Ainda, o Petrifim™ STX para contagem de S. aureus
apresentou maior capacidade de recuperação de bactérias quando comparado com
a metodologia convencional. Com base nos resultados obtidos e tendo em vista a
maior facilidade nos procedimentos e rapidez nos resultados, o sistema Petrifim™ pode ser utilizado para as análises microbiológicas em leite de ovelha. ______________________________________________________________________________ ABSTRACT / The objective of this study was to evaluate the applicability of the system Petrifilm™
in the enumeration of microorganisms indicators of quality health and hygiene
(mesophilic aerobes, coliforms and lactic acid bacteria) and pathogens (Staphylococcus aureus and Escherichia coli) in milk source sheep. Samples of milk from sheep (n = 30) were sown simultaneously, according to conventional methodologies (ICMSF; AOAC) and PetrifilmTM system. The results were compared using McNemar's test and linear regression. The results demosntrated good correlation between conventional methodologies and Petrifilm™ system. Further, the Petrifim™ STX for counting S. aureus had higher resilience of bacteria compared with the conventional methodology. Based on the results obtained and in view of the ease and rapidity procedures results, Petrifim ™ System may be used for microbiological testing in sheep milk.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/13093
Date21 February 2013
CreatorsSouza, Loiane Mayra Jacó de
ContributorsBarros, Márcia de Aguiar Ferreira
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.005 seconds