Return to search

Acurácia dimensional e visibilidade do canal mandibular na tomografia computadorizada de feixe cônico

Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T09:24:13Z (GMT). No. of bitstreams: 1
285114.pdf: 1107603 bytes, checksum: 98af1c441fcb1bf6610b33c83996e213 (MD5) / O presente estudo in vitro teve como objetivos verificar a acurácia de mensurações lineares para o planejamento de implantes nas imagens de tomografia computadorizada de feixe cônico (TCFC) obtidas com diferentes tamanhos de voxel, e analisar a visibilidade do canal mandibular nestas imagens. Doze hemimandíbulas humanas secas foram escaneadas com três tamanhos de voxels (0,2; 0,3 e 0,4mm) gerando 108 imagens transversais de TCFC, nas quais dois observadores realizaram 648 medidas e avaliaram a visualização do canal mandibular. A média geral dos erros de medição entre as medidas nas imagens e as medidas diretas (feitas por meio de paquímetro digital) foi de 0,23mm (DP± 0,20). As medidas de TCFC subestimaram as medidas diretas em 390 casos (60,2%). Todos os erros de medição encontrados foram inferiores a 1mm. De modo geral, não houve diferença estatisticamente significativa entre os erros de medição nos diferentes tamanhos de voxel e entre os observadores. Entre os dois observadores houve diferença estatisticamente significativa (p<0,05) apenas na medida em largura, nos dois sítios localizados mais posteriormente. Entre os diferentes tamanhos de voxel, houve diferença estatisticamente significativa (p<0,05) apenas para um dos observadores, em uma medida em altura, no sítio localizado na região do 1º molar. Foi possível visualizar o canal mandibular em todas as 108 imagens avaliadas. As imagens transversais de TCFC mostram-se aceitáveis para mensurações lineares na região posterior da mandíbula e com um alto desempenho na visualização do canal mandibular nos tamanhos de voxel 0,2; 0,3 e 0,4mm. Os resultados deste estudo apontam a opção por um tamanho de voxel de 0,3mm como sendo a mais propícia, pois conjuga boa qualidade da imagem e baixa dose de radiação. / The aims of the present in vitro study was to verify the accuracy of linear measurements for implant planning performed in cone beam computed tomography (CBTC) images obtained with different voxel sizes, and to analyze the visibility of the mandibular canal in these images. Twelve dry human hemimandible were scanned with three voxel sizes (0.2, 0.3 and 0.4 mm), generating 108 cross-sectional images in which two observers made 648 measurements and evaluated the visibility of the mandibular canal. The mean overall measurement errors between the measurements in the images and the direct measurements was 0.23 mm (SD ± 0.20). CBTC measurements underestimated the direct measurements in 390 cases (60.2%). All measurement errors were smaller than 1mm. Overall, no statistically significant difference between the measurement errors in different voxel sizes and among observers. Between the two observers, there was one statistically significant difference (p <0.05) in the width of two sites located more posteriorly in the mandible. Among the different voxel sizes, there was a statistically significant difference (p <0.05) for an observer at a height measured at the site located in the region of the first molar. It was possible to visualize the mandibular canal in all the 108 files evaluated. The cross-sectional images of CBCT are acceptable for linear measurements in the posterior mandible and with a high performance visualization of the mandibular canal in voxel sizes of 0.2, 0.3, and 0.4mm. The results show the option for a voxel size of 0.3 mm as the most suitable, because it combines good image quality and low radiation dose.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/94392
Date25 October 2012
CreatorsWaltrick, Karen Borges
ContributorsUniversidade Federal de Santa Catarina, Corrêa, Márcio, Abreu Junior, Murillo José Nunes de
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format92 f.| il., grafs., tabs.
Sourcereponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds