Orientador: Joaquim M. Bustorff Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-22T17:40:14Z (GMT). No. of bitstreams: 1
Aloisi_AntonioSergio_M.pdf: 1522264 bytes, checksum: 593852b61f76e5606137c4af996967ba (MD5)
Previous issue date: 1997 / Resumo: Procedimentos para alongamento do esôfago intra-abdominal são comuns a quase todas as técnicas que visam a correção do refluxo gastroesofagiano e sua eficácia tem sido observada por todos os autores através de pesquisas manométricas e de medição pre e pós operatórias do pH esofágico. Este trabalho apresenta o estudo manométrico do segmento distal do esôfago (e basicamente a zona de alta pressão), antes e após a cirurgia para alongamento do segmento intra-abdominal do esôfago. Foram utilizados doze cães, sendo realizada a manometria esofágica sob respiração espontânea no pré e pós-operatório, com registro dos dados obtidos para análise pareada. Para isso, foi utilizada uma sonda/balão, composta de uma sonda nasogástrica tipo Levine 20 FR, com balão na extremidade e completamente preenchida com água, sem bolhas de ar em seu interior Essa sonda foi conectada ao polígrafo através de transdutor, que registrava as alterações pressóricas obtidas.
Colocando-se o balão no estômago, e aplicando-se tração constante, pôde-se registrar tanto valores absolutos de pressão intra-Iuminar como a extensão em centímetros da região correspondente à ZAP. Este procedimento foi realizado antes e após a cirurgia. A técnica cirúrgica utilizada, consiste na anteriorização do segmento distal do esôfago, através de incisão longitudinal na membrana freno-esofagiana, e interessando a borda anterior do diafragma no hiato esofagiano; em seguida é realizada sutura dos pilares em posição posterior, expondo-se o segmento distal e conseguindo-se alongamento correspondente no segmento esofagiano intra-abdominal. Esta procedimento foi denominado" hiatoplastia ampliada", por descrever com clareza a manobra realizada. Os resultados finais nos permitiram concluir: 1 - A hiatoplastia ampliada provoca um aumento significativo na extensão da ZAP, detectável manométricamente. 2 - Os níveis pressóricos máximos, aparentemente, não foram afetados por esta técnica / Abstract: Aim: Intraabdominal placement of the distal esophagus is a fundamental step in every surgery aimed at correcting gastro-esophageal reflux This task may, at some times, be a very difficult one to achieve especially in children with severe esophagitis, large hiatal hernias and with GER secondary to corrected esophageal atresia. In order to overcome this problem esophageal lengthening procedures such as the Collis procedure or gastro-gastroplication have been used with variable rate of success. We have been using a simple maneuver that consists of prolonging the vertical incision of the phreno-esophageal ligament, including as much as 2 cm of the central tendon of the diaphragm and closing the hiatus posteriorly (extended hiatoplasty), thus "advancing" the esophagus, which, due to the natural concavity of the diaphragm leads to a 2 to 3 cm lengthening of the intraabdominal esophagus. The aim of this study was to evaluate manometricaly if this anatomical lengthening was accompanied by a physiological increase of the high-pressure zone (HPZ)of the gastro esophageal junction. Methods: Twelve mongrel dogs were submitted to esophageal manometry using a balloon system and continuous pull-through technique, before and after being submitted to laparotomy and extended hiatoplasty. Parameters measured included length of the HPZ, maximal recorded pressure and maximal end-expiratory pressure. Every measurement was repeated three times and th.e mean of the three measurements was utilized. Pre- and post-operative values were compared using the Wilcoxon non-parametric test accepting 0,05 as a level of significance. Results: There was a significant post-operative increase in the length of the HPZ from 48,22 ( i: 4,33 )mm to 68,69 ( i: 14,17 )mm (p<0,05). Nevertheless there was no significant change in the recorded values of maximal pressure or maximal end- expiratory pressure. These results might indicate that an additional portion of the esophagus was exposed to the positive intraabdominal pressure or that this maneuver separated anatomically the inferior esophageal sphincter from the diaphragmatic crura, thus enlarging the total length of active "sphincter". Conclusion: Our results indicate that the extended hiatoplasty results in a measurable increase in the length of the HPZ and thus can be used, together with a fundoplication, to increase the efficacy of the gastro-esophageal barrier / Mestrado / Mestre em Cirurgia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/309871 |
Date | 28 May 1997 |
Creators | Aloisi, Antonio Sergio |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Bustorff-Silva, Joaquim Murray, 1957- |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 51 f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0158 seconds