[pt] AVALIAÇÃO METROLÓGICA DE MÉTODOS DE CALIBRAÇÃO DE TRANSDUTORES PIEZOELÉTRICOS DE ALTA PRESSÃO APLICADOS A ENSAIOS BALÍSTICOS DE MUNIÇÕES LEVES / [en] METROLOGICAL EVALUATION OF CALIBRATION METHODS OF HIGH PRESSURE PIEZOELECTRIC TRANSDUCERS APPLIED TO BALLISTIC TESTS OF SMALL ARMS AMMUNITION

[pt] Os procedimentos de calibração de transdutores piezoelétricos, abordados
pela base normativa de ensaios de munições leves, carecem de detalhes cruciais
para assegurar a confiabilidade metrológica nas medições de pressão transiente
dessas munições leves. Diante deste fato, cabe aos laboratórios, como requisito para
a acreditação segundo a norma ISO/IEC 17025:2017, comprovarem a eficácia dos
métodos empregados, sobretudo nas calibrações, o que motivou a realização do
estudo. A abordagem metodológica baseou-se em pesquisas bibliográficas,
documentais, experimentais e de laboratório, visando a coleta de dados conforme
as etapas de avaliação dos métodos de calibração. Inicialmente realizou-se a
avaliação de certificados de calibração de transdutores piezoelétricos, estudando,
sobretudo, as características da regressão linear adotada pela base normativa nos
procedimentos de calibração. Nesta etapa, a pesquisa propôs a adoção da incerteza
do ajuste como parâmetro principal de avaliação de transdutores piezoelétricos,
mostrando sua viabilidade em relação ao erro de linearidade. Em seguida, foi
realizada a caracterização e modelagem da cadeia de medição de pressão transiente,
composta por transdutor piezoelétrico e amplificador de carga. A modelagem
permitiu a simulação de diferentes metodologias de calibração, resultando na
previsão de erros, e proporcionando a avaliação da influência do amplificador de
carga nas medições de pressão transiente. Por último, foram comparadas duas
metodologias distintas de calibração, destacando a importância de sistemas
automatizados de calibração para maior confiabilidade metrológica. / [en] The calibration procedures of piezoelectric transducers, addressed by the
normative basis of small arms ammunition testing, lack crucial details to ensure
metrological reliability in the transient pressure measurements of these small arms
munitions. In view of this fact, it is up to the laboratories, as a requirement for
accreditation according to ISO/IEC 17025:2017 standard, to prove the effectiveness
of the methods used, especially in calibrations, which motivated the study. The
methodological approach was based on bibliographic, documentary, experimental
and laboratory research, aiming at data collection according to the stages of
evaluation of calibration methods. Initially, the evaluation of calibration certificates
of piezoelectric transducers was carried out, studying, above all, the characteristics
of the linear regression adopted by the normative basis in the calibration procedures.
At this stage, the research proposed the adoption of fit uncertainty as the main
parameter for the evaluation of piezoelectric transducers, showing their feasibility
in relation to linearity error. Then, the characterization and modeling of the
transient pressure measurement chain, composed of a piezoelectric transducer and
a charge amplifier, was performed. The modeling allowed the simulation of
different calibration methodologies, resulting in the prediction of errors, and
providing the evaluation of the influence of the charge amplifier on transient
pressure measurements. Finally, two different calibration methodologies were
compared, highlighting the importance of automated calibration systems for greater
metrological reliability.