1 |
Challenges in Staging of Transient Pressure Ulcers Following Urologic SurgeryEllis, Anna K, Glenn, L. Lee 31 May 2011 (has links)
No description available.
|
2 |
Finite volume simulation of fast transients in a pipe systemMarkendahl, Anders January 2009 (has links)
<p>The MUSCL-Hancock finite volume method with different slope limiters has been analyzed in the context of a fast transient flow problem. A derivation and analysis of the axial forces inside a pipe system due to a flow transient is also performed. </p><p>The following slope limiters were implemented and compared: MC, van Leer, van Albada, Minmod and Superbee. The comparison was based on the method's ability to calculate the forces due to a flow transient inside a pipe system.</p><p>The tests and comparisons in this thesis show that the MC, van Leer, van Albada and Minmod limiters behave very much the same for the flow transient problem. If one would rank these four limiters with respect to the numerical error, the order would be the one presented above, the MC limiter being the most accurate. The error the four limiters produce is mainly of diffusive nature and it is just the magnitude of the diffusion that seems to differ between the methods. One should also note that the workload rank of the four limiters is the same as the order presented above. The MC limiter being the least efficient of the four and the Minmod limiter the most efficient.</p><p>In most of the tests performed the Superbee limiter display a rather negative unpredictable behavior. For some relatively simple cases this particular approach shows big difficulties maintaining the dynamical properties of the force. However, the upside of the Superbee limiter is its remarkable ability to maintain the maximum value of the forces present in the pipe system, preventing underestimation of the maximum magnitude of the force.</p>
|
3 |
Finite volume simulation of fast transients in a pipe systemMarkendahl, Anders January 2009 (has links)
The MUSCL-Hancock finite volume method with different slope limiters has been analyzed in the context of a fast transient flow problem. A derivation and analysis of the axial forces inside a pipe system due to a flow transient is also performed. The following slope limiters were implemented and compared: MC, van Leer, van Albada, Minmod and Superbee. The comparison was based on the method's ability to calculate the forces due to a flow transient inside a pipe system. The tests and comparisons in this thesis show that the MC, van Leer, van Albada and Minmod limiters behave very much the same for the flow transient problem. If one would rank these four limiters with respect to the numerical error, the order would be the one presented above, the MC limiter being the most accurate. The error the four limiters produce is mainly of diffusive nature and it is just the magnitude of the diffusion that seems to differ between the methods. One should also note that the workload rank of the four limiters is the same as the order presented above. The MC limiter being the least efficient of the four and the Minmod limiter the most efficient. In most of the tests performed the Superbee limiter display a rather negative unpredictable behavior. For some relatively simple cases this particular approach shows big difficulties maintaining the dynamical properties of the force. However, the upside of the Superbee limiter is its remarkable ability to maintain the maximum value of the forces present in the pipe system, preventing underestimation of the maximum magnitude of the force.
|
4 |
[pt] AVALIAÇÃO METROLÓGICA DE MÉTODOS DE CALIBRAÇÃO DE TRANSDUTORES PIEZOELÉTRICOS DE ALTA PRESSÃO APLICADOS A ENSAIOS BALÍSTICOS DE MUNIÇÕES LEVES / [en] METROLOGICAL EVALUATION OF CALIBRATION METHODS OF HIGH PRESSURE PIEZOELECTRIC TRANSDUCERS APPLIED TO BALLISTIC TESTS OF SMALL ARMS AMMUNITIONCAIO BITTENCOURT CARDOSO FELIX 15 July 2024 (has links)
[pt] Os procedimentos de calibração de transdutores piezoelétricos, abordados
pela base normativa de ensaios de munições leves, carecem de detalhes cruciais
para assegurar a confiabilidade metrológica nas medições de pressão transiente
dessas munições leves. Diante deste fato, cabe aos laboratórios, como requisito para
a acreditação segundo a norma ISO/IEC 17025:2017, comprovarem a eficácia dos
métodos empregados, sobretudo nas calibrações, o que motivou a realização do
estudo. A abordagem metodológica baseou-se em pesquisas bibliográficas,
documentais, experimentais e de laboratório, visando a coleta de dados conforme
as etapas de avaliação dos métodos de calibração. Inicialmente realizou-se a
avaliação de certificados de calibração de transdutores piezoelétricos, estudando,
sobretudo, as características da regressão linear adotada pela base normativa nos
procedimentos de calibração. Nesta etapa, a pesquisa propôs a adoção da incerteza
do ajuste como parâmetro principal de avaliação de transdutores piezoelétricos,
mostrando sua viabilidade em relação ao erro de linearidade. Em seguida, foi
realizada a caracterização e modelagem da cadeia de medição de pressão transiente,
composta por transdutor piezoelétrico e amplificador de carga. A modelagem
permitiu a simulação de diferentes metodologias de calibração, resultando na
previsão de erros, e proporcionando a avaliação da influência do amplificador de
carga nas medições de pressão transiente. Por último, foram comparadas duas
metodologias distintas de calibração, destacando a importância de sistemas
automatizados de calibração para maior confiabilidade metrológica. / [en] The calibration procedures of piezoelectric transducers, addressed by the
normative basis of small arms ammunition testing, lack crucial details to ensure
metrological reliability in the transient pressure measurements of these small arms
munitions. In view of this fact, it is up to the laboratories, as a requirement for
accreditation according to ISO/IEC 17025:2017 standard, to prove the effectiveness
of the methods used, especially in calibrations, which motivated the study. The
methodological approach was based on bibliographic, documentary, experimental
and laboratory research, aiming at data collection according to the stages of
evaluation of calibration methods. Initially, the evaluation of calibration certificates
of piezoelectric transducers was carried out, studying, above all, the characteristics
of the linear regression adopted by the normative basis in the calibration procedures.
At this stage, the research proposed the adoption of fit uncertainty as the main
parameter for the evaluation of piezoelectric transducers, showing their feasibility
in relation to linearity error. Then, the characterization and modeling of the
transient pressure measurement chain, composed of a piezoelectric transducer and
a charge amplifier, was performed. The modeling allowed the simulation of
different calibration methodologies, resulting in the prediction of errors, and
providing the evaluation of the influence of the charge amplifier on transient
pressure measurements. Finally, two different calibration methodologies were
compared, highlighting the importance of automated calibration systems for greater
metrological reliability.
|
5 |
Well testing in gas hydrate reservoirsKome, Melvin Njumbe 16 January 2015 (has links)
Reservoir testing and analysis are fundamental tools in understanding reservoir hydraulics and hence forecasting reservoir responses. The quality of the analysis is very dependent on the conceptual model used in investigating the responses under different flowing conditions.
The use of reservoir testing in the characterization and derivation of reservoir parameters is widely established, especially in conventional oil and gas reservoirs. However, with depleting conventional reserves, the quest for unconventional reservoirs to secure the increasing demand for energy is increasing; which has triggered intensive research in the fields of reservoir characterization. Gas hydrate reservoirs, being one of the unconventional gas reservoirs with huge energy potential, is still in the juvenile stage with reservoir testing as compared to the other unconventional reservoirs. The endothermic dissociation hydrates to gas and water requires addressing multiphase flow and heat energy balance, which has made efforts to develop reservoir testing models in this field difficult.
As of now, analytically quantifying the effect on hydrate dissociation on rate and pressure transient responses are till date a huge challenge.
During depressurization, the heat energy stored in the reservoir is used up and due to the endothermic nature of the dissociation; heat flux begins from the confining layers. For Class 3 gas hydrates, just heat conduction would be responsible for the heat influx and further hydrate dissociation; however, the moving boundary problem could also be an issue to address in this reservoir, depending on the equilibrium pressure. To address heat flux problem, a proper definition of the inner boundary condition for temperature propagation using a Clausius-Clapeyron type hydrate equilibrium model is required.
In Class 1 and 2, crossflow problems would occur and depending on the layer of production, convective heat influx from the free fluid layer and heat conduction from the cap rock of the hydrate layer would be further issues to address. All these phenomena make the derivation of a suitable reservoir testing model very complex. However, with a strong combination of heat energy and mass balance techniques, a representative diffusivity equation can be derived.
Reservoir testing models have been developed and responses investigated for different boundary conditions in normally pressured Class 3 gas hydrates, over-pressured Class 3 gas hydrates (moving boundary problem) and Class 1 and 2 gas hydrates (crossflow problem). The effects of heat flux on the reservoir responses have been addressed in detail.
|
Page generated in 0.1104 seconds