Previous issue date: 1201-02-11 / CAPEs / O objetivo deste estudo foi validar o uso da técnica da tomografia por
coerência óptica através de experimento in vitro para avaliar a cimentação e
a linha de união laminado-cimento-dente antes e depois da termociclagem,
visando a aplicação clínica deste instrumento. Além de comparar diferentes
modalidades de materiais e protocolos de cimentação. A técnica da
tomografia por coerência óptica (TCO) é um método não invasivo,
quantitativo e qualitativo, e foi utilizado para avaliação da qualidade póscimentação
do laminado, minimizando possíveis erros, e proporcionando
acompanhamento clínico sem exposição a radiação ou qualquer
procedimento invasivo. Foram feitas imagens em 2D e 3D dos laminados e
das superfícies dentais antes e depois da cimentação e do processo de
ciclagem térmica. Os laminados (20) foram cimentados na superfície de
esmalte bovino de acordo com uma distribuição aleatória em 4 grupos
(n=05): FA – cimento resinoso dual com fotoativação prévia do adesivo; FC –
cimento resinoso dual sem fotoativação prévia do adesivo; AF - cimento
resinoso autocondicionante dual com fotoativação; AQ - cimento resinoso
autocondicionante dual com polimerização química. Os laminados foram
fabricados em porcelana modificada por dissilicato de lítio, na espessura de
0,5 mm. As análises foram feitas através de imagens 2D e 3D com o TCO.
Os resultados mostraram claramente a presença de bolhas com dimensões
típicas que variaram de 146 μm a 1427 μm, além de falhas como a presença
de gap e até a desadaptação do laminado. Parte dessas falhas, já estavam
presentes imediatamente após o processo de cimentação e após a ciclagem
térmica mantiveram-se estáveis ou foram acentuadas. Os resultados indicam
que um acompanhamento periódico de pacientes que utilizam laminados
cerâmicos é de fundamental importância para garantia da manutenção da
qualidade do procedimento, bem como evitar problemas na saúde bucal.
Propomos então a técnica de TCO como padrão para este procedimento. / The aim of this study was to validate the use of optical coherence tomography
(OCT) through in vitro experiment to evaluate the cementing and the union
line of lumineer-cement-tooth before and after the thermal cycling. In addition
to comparing different types of materials and cementation protocols. The
technique of optical coherence tomography (OCT) is a noninvasive,
quantitative and qualitative method, and was used to evaluate the postcementation
quality of the lamina, minimizing potential errors, and providing
clinical follow-up without exposure to radiation or any invasive procedure.
Were made in both 2D and 3D imaging of tooth surfaces and the laminate
before and after the cementing and the thermocycling process. 20 specimens
of lumineers-teetth were prepared in bovine teeth and randomly allocated in 4
experimental groups (n=5) with two different cementation techniques and two
different types of cementing agent: FA - dual resin cement with prior photo
activation of the adhesive; FC - dual resin cement without curing the
adhesive; AF - self-etching resin cement with photoactivation; AQ - selfetching
resin cement with chemical polymerization. The lumineers were made
of lithium disilicate and obtained using a vacuum injection technique,
thickness of 0.5 mm. The analysis was performed by using 2D and 3D OCT
images, obtained before and after the thermal cycling. The results showed the
presence of bubbles with typical size ranging from 146 μm to 1427 μm, and
faults as the presence of gap and laminate mismatch. Some of these faults
were already present immediately after the process of cementing and after
thermal cycling remained stable or were marked. The results indicate that
regular monitoring of patients using lumineers is of fundamental importance
for ensuring the maintenance of the quality of the procedure and how to avoid
problems in oral health. Then we propose the OCT technical default for this in
vivo to follow-up.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/17070
Date11 February 2015
CreatorsBORGES, Érica de Andrade
Contributorshttp://lattes.cnpq.br/8841334894205599, GOMES, Anderson
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Odontologia, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguageBreton
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.0056 seconds